- Electricity - Electronics >
- Switch and Relay >
- Distribution circuit breaker
Distribution circuit breakers
Primary current: 630 A - 4,000 A
VAC: 12, 17.5, 24 kV
... or multi-breaking short circuit current, may be mounted in the indoor air insulating switchgear like type KYN28 or AMS, ABB type ZS1 series, etc. This circuit breaker is standards as ...
Primary current: 10, 63 A
VDC: 1,000 V
... The circuit breaker has the functions of short circuit protection, overload protection, control, isolation and so on. It is suitable for terminal power distribution, civil construction, ...
Primary current: 2,500 A - 100,000 A
... fuse-free circuit breaker (and power-leakage circuit breaker) (50-1600AF/2.5kA-100kA), offering basic electricity protection for commercial or industrial power- distribution ...
Primary current: 1 A - 63 A
VAC: 110 V - 480 V
... Protection of circuits against short- circuit currents, Protection of circuits against overload currents, Switch, Isolation, Circuit- breakers are used in domestic ...
Primary current: 6 A - 800 A
VAC: 400, 690 V
... mainly used in the circuit of AC 50/60Hz, rated insulating voltage 690V (630 type is 500V), rated working voltage up to 690V, and rated current from 6A-800A in distribution line for distributing power, protecting line, ...
Radin Electric Technology Co., lTD
Primary current: 160 A
... EQUES®CrossBoard. circuit breakers up to 160 A mounted on the CrossBoard®. Adapter, 90 mm wide, to accept circuit breakers of different manufacturers. This combination of circuit ...
Wöhner
Primary current: 45,000 A
VAC: 230, 415 V
VDC: 60 V
... miniature circuit breakers have been designed for protection of electrical installations against overload and short circuits and are manufactured in accordance with IEC 60898-1 Technical Data • Handle ...
IMO Precision Controls Limited
Primary current: 1 A - 40 A
... requirement for protection against overload and short circuit for all domestic, commercial and any low voltage distribution systems. · Only 18mm for 2P and 36mm for 3P+N/4P · Overloaded and short circuit ...
WENZHOU RENA ELECTRIC CO.,LTD
Primary current: 4,000, 2,500 A
VDC: 1,000 V
... ejection in its operation, AFB® circuit breaker applies principle of power circuit interruption in vacuum. As a result, AFB® circuit breaker requires half the size of ...
Primary current: 630, 1,250, 2,000 A
VAC: 12 kV
... The BSR is an OEM designed retrofit circuit breaker for both the BRUSH Switchgear VSI range of Oil Circuit Breakers and the VMV vacuum Circuit Breaker, ...
Primary current: 630 A - 1,600 A
VAC: 12 kV
... VS1 series vacuum circuit breaker is an indoor type high voltage equipment with rated voltage7.2~11KV,50HZ.It complies with GB/T 1984,JB3855 and related IEC standards.It can be frequently operated and has function of ...
Wenzhou Zeen Electric Co.,Ltd
VAC: 660, 690 V
... the mark The circuit breaker complies with the requirements of the standards GB140482″Low voltage switchgear and controlgear-Part2:Low voltage circuit – breakers and ...
Primary current: 400 A - 2,000 A
VAC: 400, 690 V
... marine type and 1E circuit breakers, circuit breakers with low temperature of up to -40℃, as well as LCD and LED display circuit breakers. • Intelligence, ...
SHANGHAI ANSON ELECTRIC TECHNOLOGY CO.,LTD
Primary current: 630, 1,250 A
VAC: 12 kV
... permanent magnetic vacuum circuit breaker is used in tri-phase electric system of AC 50 Hz, rated voltage 12kV. It is suitable for breaking, closing load current, overload current and short- circuit current, ...
Wenzhou Vacem Technology Co., Ltd
Primary current: 0 A - 1,600 A
VAC: 550, 800 V
... of a circuit breaker provides the feature of inverse time-delay, while the magnetic release is the instantaneous operation as shown on table 2( distribution circuit breaker) ...
Andeli Group Company
Primary current: 6,000 A
VAC: 230 V
Rating: 25 A
... - Tripping curve: B, C B - The maximum current release breaks between 3 and 5 In; used to protect long circuits and generators С - The maximum current release breaks between 5 and 10 In; used to protect main power supply cables and ...
Elmark
Primary current: 200 A - 1,000 A
VAC: 400, 380 V
... RDW1-1000 air circuit breaker, applied to power distribution network of AC50Hz, Rated voltage 400V (or 380V), Rated current from 200A to 1000A. It is mainly used to distribute electric power and protect ...
PEOPLE ELE. APPLIANCE GROUP CO., LTD.
Primary current: 5 A - 60 A
VDC: 24, 48, 12 V
... applications. Engineered into a standard 1RU footprint, each circuit supports up to 60A breakers in each position, providing ample capacity for distribution to a broad range of components. Advanced circuit-level ...
Primary current: 1 A - 10 A
VDC: 12, 24 V
... MRF102 2-channel electronic circuit breaker is designed for current distribution and protection of DC 12V or 24V load circuits. The MRF102 is Din Rail mounting or wall mounting. The ...
Primary current: 20 A
As part of fire fighting, emergency cutting boxes are red. They must be installed outside the boiler room to ensure a safe cut. The front glass face can easily be broken with a hammer. 2 LEDs (red and green) make it possible to check the state of the ...
Primary current: 6,000 A
VAC: 230, 400 V
... SFB2A series circuit breakers are applicable for places with AC 50Hz or 60Hz, rated voltage of 400V and below, and rated current of 16A-80A. It is mainly used for overload and short- circuit protection ...
the best suppliers
Subscribe to our newsletter
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group