Primary current: 2,500 A
VAC: 52, 72.5 kV
Well proven circuit breaker based on modular design, factory assembled and tested for rapid installations The EDF SK is a live tank SF6 AutopufferTM circuit breaker. ...

LW8-40.5 Outdoor AC High Voltage SF6 Circuit Breaker Category:Components

Primary current: 0 A - 2,000 A
VAC: 40.5, 38, 36 kV
... -blast principle. This live tank circuit breaker provides a high level of reliability for customers, even under extreme conditions and climates or in highly active seismic areas. The GL 107X live tank ...

Primary current: 0 A - 3,150 A
VAC: 72.5 V - 145 V
Vacuum technology – Sustainable high-voltage circuit breakers The outstanding technical performance and low lifecycle cost of vacuum circuit breakers make this solution ...
Siemens High-voltage – Power transmission

... protection. You could either select a higher-cost transformer switch with advanced protection capabilities, like a circuit-switcher or circuit breaker, or you could choose a lower-cost ...

Primary current: 630 A
VAC: 12 kV
... high-voltage AC vacuum circuit breaker is an outdoor pole-mounted switch of vacuum arcing and SF6 insulation. It is featured by small, and excellent climatic protection performance, etc., and it mainly ...

Primary current: 4,000, 5,000 A
VAC: 550, 800, 252, 363 kV
... tightness technology, high design parameters, the whole structure of circuit breaker is compact, with stable and reliable performance and long endurance. 1 The circuit breaker ...
Henan ping high electric co., LTD.

Primary current: 0 A - 2,000 A
VAC: 0 kV - 36 kV
... high altitudes. In low inductive and capacitive currents the SF6 GCB is highly suitable. It continuously supervises the SF6 gas pressure.
CG Power Systems

VAC: 72.5 kV
Transmission , Distribution and Substation 72.5KV Live Tank SF6 Circuit Breaker

Primary current: 400, 630, 800, 1,250 A
VAC: 12 kV
The SWR12 is an OEM designed retrofit circuit breaker for both the South Wales Switchgear C & D range Oil Circuit Breaker and the HG12 Gas Circuit ...
BRUSH Group
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining