Primary current: 15 A - 60 A
... Electromechanical Circuit Breakers (CB) with several different terminals (FASTON, EN, MIL...) and accessories. ...
Crouzet
Primary current: 15 A - 60 A
... Electromechanical Circuit Breakers (CB) with several different terminals (FASTON, EN, MIL...) and accessories. ...
Crouzet
Primary current: 3,150 A - 4,000 A
VAC: 40.5 kV - 363 kV
... ETGI-1.020, IEEE Std 693, NCh2369 • Structural design, ASTM A325, ANSI/AISC 360, AWS D1.1 • High altitude correction per IEC 62271 & IEEE C37, ~ 5000m • High current switching capability, Reliable and Flexible solutions ...
Dowei Electric
Primary current: 3,150 A - 4,000 A
VAC: 40.5 kV - 363 kV
... ETGI-1.020, IEEE Std 693, NCh2369 • Structural design, ASTM A325, ANSI/AISC 360, AWS D1.1 • High altitude correction per IEC 62271 & IEEE C37, ~ 5000m • High current switching capability, Reliable and Flexible solutions ...
Dowei Electric
Primary current: 600 A - 3,000 A
VAC: 4.16 kV - 40.5 kV
VDC: 110 V - 220 V
... , UL, ASTA • Seismic design, ETGI-1.020, IEEE Std 693, NCh2369 • Structural design, ASTM A325, ANSI/AISC 360, AWS D1.1 • High altitude correction per IEC 62271 & IEEE C37, ~ 5000m • Porcelain bushings with extended creepage for higher ...
Dowei Electric
Primary current: 630 A - 800 A
VAC: 15 kV - 38 kV
Rating: 12.5 A - 20 A
... NCh2369 • Structural design, ASTM A325, ANSI/AISC 360, AWS D1.1 • High altitude correction per IEC 62271 & IEEE C37, ~ 5000m • HCEP encapsulated vacuum interrupters with excellent performance • Painted 304 stainless ...
Dowei Electric
Primary current: 630 A - 4,000 A
VAC: 12 kV - 40.5 kV
... , UL, ASTA • Seismic design, ETGI-1.020, IEEE Std 693, NCh2369 • Structural design, ASTM A325, ANSI/AISC 360, AWS D1.1 • High altitude correction per IEC 62271 & IEEE C37, ~ 5000m • Highly reliable vacuum interrupter embedded in the ...
Dowei Electric
Primary current: 80 A - 250 A
VDC: 500 V
... Direct Current Molded Case Circuit Breaker for Solar PV Battery Energy Storage System (BESS) and UPS applications. The BESS systems including batteries requires reliable and safety ...
Primary current: 6,000 A
VAC: 230 V - 400 V
Rating: 2 A - 63 A
... breaks between 3 and 5 In; used to protect long circuits and generators С - The maximum current release breaks between 5 and 10 In; used to protect main power supply cables and conventional consumers - Electrical ...
Elmark
Primary current: 6,000 A
VAC: 400 V
Rating: 2 A - 63 A
... breaks between 3 and 5 In; used to protect long circuits and generators С - The maximum current release breaks between 5 and 10 In; used to protect main power supply cables and conventional consumers - Electrical ...