Mechanical drains

21 companies | 37 products
{{#pushedProductsPlacement4.length}} {{#each pushedProductsPlacement4}}
{{product.productLabel}}
{{#if product.activeRequestButton}}
{{/if}}
{{product.productLabel}}
{{product.model}}

{{#each product.specData:i}} {{name}}: {{value}} {{#i!=(product.specData.length-1)}}
{{/end}} {{/each}}

{{{product.idpText}}}

{{productPushLabel}}
{{#if product.newProduct}}
{{/if}} {{#if product.hasVideo}}
{{/if}}
{{/each}} {{/pushedProductsPlacement4.length}}
{{#pushedProductsPlacement5.length}} {{#each pushedProductsPlacement5}}
{{product.productLabel}}
{{#if product.activeRequestButton}}
{{/if}}
{{product.productLabel}}
{{product.model}}

{{#each product.specData:i}} {{name}}: {{value}} {{#i!=(product.specData.length-1)}}
{{/end}} {{/each}}

{{{product.idpText}}}

{{productPushLabel}}
{{#if product.newProduct}}
{{/if}} {{#if product.hasVideo}}
{{/if}}
{{/each}} {{/pushedProductsPlacement5.length}}
condensate drain
condensate drain
HM series

Operating pressure: 13 bar - 123 bar

... eliminating the risk of leaks to atmosphere. Mechanical steam traps Inverted bucket mechanical steam traps Our inverted bucket steam traps employ ...

See the other products
Spirax Sarco
condensate drain
condensate drain

The fixed temperature discharge steam trap employs a liquid expansion device to discharge condensate at a predefined temperature. It can easily be adjusted on site to any temperature within the operating range.

See the other products
Spirax Sarco
condensate drain
condensate drain

Inverted bucket traps are the most robust type of the mechanical traps. Able to resist waterhammer. With check valve fitted in the inlet, they can be used with superheated steam. Available with ...

See the other products
Spirax Sarco
bimetallic drain
bimetallic drain
ARI-CONA B

Operating pressure: 16, 40 bar
Operating temperature: -50 °C - 450 °C

eClass-No.:37010708 Application:For the discharge of condensate sub-cooled between 10 and 30 K Medium:Steam, condensate, etc.

condensate drain
condensate drain
5890x series

Operating pressure: 25 bar

FLOAT STEAM TRAP BSP THREADED - STAINLESS STEEL 304

condensate drain
condensate drain
ZERO series

Operating pressure: 16 bar

The ZERO series is a drain that is suitable to use in compressed air treatment applications. It minimizes space requirements as it can be set up under the tank, and it also has reduced servicing as it is equipped with ...

condensate drain
condensate drain
3/8 - 1", 600 psi

... seat and disc are replaceable without removing the trap body from the line. When FD traps are used in vertical installations with outlets in the down position, the traps are self-draining ...

condensate drain
condensate drain
516

Drain 516D - 1/8" for HankisonUltrafi lter 80s, Item no:A-516-D EUR 63,00

condensate drain
condensate drain
AOK 20B

Operating pressure: 20 bar
Operating temperature: 2 °C - 65 °C

AOK20B SERIES Automatic Mechanical Condenstate Drain has an operating pressure of 20 bar. The drain capacity is 167 l/h. The inlet connection is 1/2. The operating temperature range is ...

See the other products
OMEGA AIR d.o.o. Ljubljana
condensate drain
condensate drain
MCD

Operating pressure: 16 bar

This MCD Automatic Mechanical Condensate Rain system contains an operating pressure with 20 bar, and has an operating temperature range of 1.5 to 65°C. This product can be used in air filters. The MCD has been improved ...

See the other products
OMEGA AIR d.o.o. Ljubljana
condensate drain
condensate drain
AOK 13PA

Operating pressure: 1 bar - 13 bar
Discharge capacity: 0 kg/h - 167 kg/h
Operating temperature: 2 °C - 65 °C

Automatic mechanical condensate drain AOK 13PA has been developed for fully automatic discharging of condensate or any other non-aggressive fluid from compressed air system. The unit can be installed ...

See the other products
OMEGA AIR d.o.o. Ljubljana
condensate drain
condensate drain
32 bar | AIC series

For pressure to 465 psig (32 barg) ... Capacities to 60,075 lb/hr (27 250 kg/hr) Armstrong AIC Series F&T traps are designed for industrial service from 0 to 465 psig (32 barg). They feature all the benefits of Armstrong ...

See the other products
Armstrong International, Inc.
condensate drain
condensate drain
32 bar, 2" | ICS series

... Float and Thermostatic Steam Trap is used for continuous drainage of condensate and high-capacity venting of air and CO2, when steam pressure may vary from maximum steam supply pressure to vacuum. Armstrong ...

See the other products
Armstrong International, Inc.
condensate drain
condensate drain
32 bar | CS series

... For pressures to 465 psig (32 bar) . . . Capacities to 13,281 lb/hr (6024 kg/hr) Note: CS Series Float & Thermostatic Steam Traps have now been replaced by the ICS Series Float & Thermostatic Steam Traps. Repair parts ...

See the other products
Armstrong International, Inc.
air drain
air drain
CDV1 series

Operating pressure: 200 psi
Operating temperature: 175 °F

The CDV1 Series is a zero air loss, pneumatic, mechanical drain that is designed to automatically remove liquid, oil, and water contaminants from compressed air system components. The efficient bowl size ...

condensate drain
condensate drain

Operating pressure: 2 bar - 12 bar

*“SAD” automatic drain allows draining condensate, which is within the bowl, both when it is pressurized and depressurized. *It is a differential type drain: when the condensate preset level ...

condensate drain
condensate drain

Operating pressure: 0 bar - 13 bar
Operating temperature: 5 °C - 50 °C

In the absence of pressure the outlet remains opened, thus ensuring that all settled fluid particles are eliminated. Equipped with hose nipple to convey the collected condensate away. To allow servicing operations, pressure can be relieved ...

condensate drain
condensate drain
EWD, WD series

... wide range of EWD drains is available for oil-contaminated condensate. This includes models with an additional hard coating for use with oil-free and aggressive condensate Electronically controlled condensate drains The ...

condensate drain
condensate drain

Mechanical, automatically operating valve for tapping condensation water from compressors, filters, dryers, separators and air receivers. Internal screw thread. With control valve.

See the other products
AIRPRESS
condensate drain
condensate drain
SCL

Drip leg drain Mod. SCL Drip leg drain Thread: 1/2"

condensate drain
condensate drain
ST-200A

Operating pressure: 0 bar - 16 bar

Working Bar​ 0〜16 Inlet (Inch) 1/2 Outlet (Inch) 1/2 Voltage AC (V) 110 or 220 Compressor (M³/Min) ​ 30 Dryer (M³/Min) 60 Filter (M³/Min) 300 Weight (Kg) 1.5 Discharge Channel(mm) 10

air drain
air drain
JMB-RxxB/EB series

... to its on-board power source and self-contained operation, the JMB-R drain cleaner is easy to use in even in places where there is no electricity, and ideally suited for cleaning drains, piping, waste ...

condensate drain
condensate drain
NUFORS-DC

The NUFORS-DC removes condensate from compressed air systems without using electricity. The discharge process is automatic and is based on a 2/2 way level controlled valve principle that operates a direct cylinder valve. The NUFORS-DC ...

See the other products
Jorc Industrial
condensate drain
condensate drain
WA

Operating pressure: 0 bar - 16 bar
Operating temperature: 0 °C - 60 °C

Port G1/4, 4 mm Pressure 0 ... 16 bar Fully automatic condensate drain Manual override Special features: For attaching to service units

water drain
water drain
1323 series

Operating pressure: 10 bar
Operating temperature: 4 °C - 110 °C

steam trap
steam trap
SLTT-76

UNIQUE FEATURES: -Corrosion Resistance SS Body construction. -Uniquely Designed Maintainable Seat. -Oxidation free heat treatment for seat & disc. -Differential hardness value for seat & disc. -Function test - 100 % on steam.

water drain
water drain

The automatic bottom purging unit prevents unnecessary purging duplication or omission verifiable with the manual system. This system allows sludge accumulated at the bottom of the generator to be regularly and automatically evacuated ...

gas drain
gas drain
HP 560

Operating pressure: 0 bar - 300 bar
Operating temperature: -20 °C - 70 °C

The three-way purge block HP 560 was designed in order to guard against the lack of space in modern gas cylinder cabinets. For this purpose a short cylinder conections and the close fitting purge valves are installed, which also simplifies ...