- Electricity - Electronics >
- Switch and Relay >
- Motorized circuit breaker
Motorized circuit breakers
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
Primary current: 0 A - 3,150 A
VAC: 31,500 V - 145,000 V
... Product Overview
ZW39 Vacuum
Circuit
Breaker is an outdoor high-voltage AC switching device designed for power transmission and distribution. It integrates vacuum interrupters with a fluorine-free insulating ...
Primary current: 200 A - 6,300 A
VAC: 690, 400 V
... type: 3 level 3.7 - Installation type: Type of circuit breaker main circuit, under voltage release, primary coil of power transformer is installation IV; type of Auxiliary circuit ...
VAC: 240, 415 V
Rating: 6 A - 63 A
... RECmax MP series are motorized circuit breakers that can be linked remotely. They offer protection against short- circuits and overloads, and can also be used as a circuit ...
Primary current: 6 A - 63 A
VAC: 240, 415 V
... The motorized circuit breakers of the MT Series can be associated remotely. They protect against short- circuits and overloads, but are also used as a circuit breaker. ...
Primary current: 630 A
VAC: 12 kV
The switches are designed for normal operating conditions acc. to EN 62271¬1, Class "Minus 5 Indoor”. A proper functioning is also guaranteed up to temperatures of up to ¬15°C. The maximum value of the ambient temperature is 40°C; the average value over ...
Primary current: 3,150 A - 4,000 A
VAC: 40.5 kV - 363 kV
... Requirements and testing for AC high-voltage
circuit
breakers.
·IEEE C37 Series – North American standards covering ratings, testing, and application.
A live tank
circuit
breaker ...
Dowei Electric
Primary current: 3,150 A - 4,000 A
VAC: 40.5 kV - 363 kV
... 5000m
• High current switching capability, Reliable and Flexible solutions
Dead Tank
Circuit
Breaker (DTC) is a high-voltage outdoor
circuit
breaker in which the interrupter ...
Dowei Electric
Primary current: 600 A - 3,000 A
VAC: 4.16 kV - 40.5 kV
VDC: 110 V - 220 V
... Requirements for AC
circuit
breakers, including many outdoor vacuum
breaker designs.
·IEC 62271-1 – General requirements for high-voltage switchgear and controlgear.
·IEEE C37.04 – Defines ratings ...
Dowei Electric
Primary current: 630, 1,250 A
VAC: 12, 24, 17.5 kV
VDC: 36 kV
... lightweight architecture. The working system is standard or motorized stored energy type with closing and opening release that are fit for local and remote applications. The remote control of the circuit- breaker ...
SAREL
the best suppliers
Subscribe to our newsletter
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group