- Electricity - Electronics >
- Switch and Relay >
- Multipole disconnect switch
Multipole disconnect switches
Primary current: 300 A
VAC: 240 V - 280 V
... TYPE 4245 MANUAL MAGNETIC DISCONNECT SWITCH. The Manual-Magnetic Disconnect Switches are combination manually and magnetically operated contactors enclosed in a NEMA Type wall-mounted or floor-mounted ...
Primary current: 0 A - 800 A
VAC: 0 V - 4,000 V
... The XMS is a modular off-load disconnect switch, packed in a closed insulated housing, that enables to build up to 3-pole independent or synchronized units. Used in railway locomotives and trains, the XMS is installed ...
Secheron
Primary current: 3 A - 32 A
VDC: 500, 600, 800, 1,000 V
... compliant with AS60947.3:2018 DC-PV2 and IEC60947. 1000V True DC for solar PV application IP66 1000V 32A true DC isolator switch BYH-32 is developed for Australia and worldwide solar installation. Be installed ...
Zhejiang Benyi Electrical Co.,ltd.
Primary current: 0 A - 300 A
VDC: 110, 23, 36, 72 V
... LTRM disconnector is designed for applications up to 4 kV and are available with electric motor control (24, 36, 72, 110 VDC). Its compact dimensions make it particularly suitable for application up to 300 A where 3 or 4 poles (1NO+1NC ...
Microelettrica
Primary current: 630, 1,250, 1,600, 2,000 A
VAC: 40.5, 72.5, 126, 145 kV
... GW7 Series disconnector are 3-pole outdoor HV a.c electric devices, including 40.5kV, 72.5kV, 126kV and 145 kV disconnectors, which own 3-pole double-horizontal-break construction, consist of installation base, supporting insulator, rotating ...
VAC: 10 kV
... research and development ability to develop a capacitor power-taking Intelligent pole-mounted Switch that no need the PT power-taking. (1) Improve safety reliability and solve PT explosion problems completely: The ...
Primary current: 25 A - 100 A
... opening amplitude and connection terminals are amply sized. - Degree of protection: up to IP 66 - For 25A to 100A size switches - Cable entries with pre-formed knockouts - Tamper-proof cover with padlockable handle - Recessed area ...
BACO
Primary current: 16 A - 100 A
VAC: 690 V
VDC: 600 V
... - 40A switches) EN 60947-3 Low voltage switchgear and controlgear Part 3: switches disconnectors, switch-disconnectors and fuse-combination unit UL 508 Industrial control equipement ...
Primary current: 12 A - 80 A
... . Fully manufactured in cast 304 stainless steel Dimensions (H x W x D): 165 mm x 120 mm x 117 mm Equipped with disconnect switch from WEG, Schneider or ABB brands and two cable glands M25 (14-17) ...
Primary current: 400, 630 A
VAC: 12, 24, 36 kV
... The Pomanique’s single break, insulator operated disconnector has been designed for both rural distribution and substation type disconnector applications and complying with IEC 60129. Rated voltage from 12kV to 36kV, ...
Pomanique Electric
Primary current: 80, 100, 40, 63 A
VAC: 690, 400, 415 V
... EMC Cable Area to Switch Terminal (only Cu) (mm2) / Bolt size - 2.5-35 Cable Gland - 2xM40 Color - Standard Enclosure - A4 Enclosure Type - Aluminium IP Rating - 66 Operation - Front-operated Switch type - Load ...
KATKO
Primary current: 400 A - 2,000 A
... Size NH 2/3, 400/630/1000/2000 A, 185 mm busbar spacing | 438 Type BTVC-S | 3 Pole vertical design disconnectors ...
PRONUTEC S.A.U.
Primary current: 63 A
VAC: 240, 440 V
EMS Electro Mecanicals Systems
... indicated on both handle and switch. Door interlocking is provided by the handle.The design of the switch provides a direct connection on the switch terminals and is expandable with auxiliary switches ...
Primary current: 0 A - 63 A
VAC: 690 V
VDC: 440 V
... module 4x NH fuse- switch-disconnector, 3-pole clamp connection 4x NH 000 (max. 63 A) for busbars 30, 40, 60, 80, 100, 120 x 10 NEW System 185Power Product group - 09 Subgroup - 37 pack size - 1 EAN - 4021267337773 ...
Wöhner
Primary current: 100 A
VAC: 400, 230 V
... A reliable and trusted main isolating switch disconnect is crucial for ensuring the safety of electricians and maintenance engineers working on your aplication. The IMO range of isolating switch ...
IMO Precision Controls Limited
Primary current: 32 A - 315 A
... power. The KSD Switch Disconnector is not designed for security purposes. No hazardous substances were used in the manufacture of this product. APPLICATION The KSD safety component ...
Primary current: 16 A
... 158X121X126 mm Depth - - CAM layout - 1 Flush-mounting dimensions - - No. discs - - Function Apparatus Control - One way switches ...
Palazzoli S.p.A.
Primary current: 0 A - 32 A
VAC: 1,200 V
VDC: 1,200 V
... ASL4-32 series DC Isolator Switches are applied to 1-20KW Inverter, Controller, DC Combiner Box, used for Residential or Commercial PV solar power system(on-grid/off-grid). Arcing time less than 3ms, that make PV solar system effectively ...
SHANGHAI ANSON ELECTRIC TECHNOLOGY CO.,LTD
Primary current: 21, 22, 23 A
VAC: 490, 230, 400 V
... EVO40 is a multipole safety switch-disconnector with independent manual rotary control, designed for on-load shutdown/breakdown and safety isolation of LV electrical circuits. Highlights •Up ...
the best suppliers
Subscribe to our newsletter
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group