Voltage circuit breakers
Primary current: 25 A - 1,600 A
VAC: 750 V
... Moulded Case Circuit Breakers are produced according to IEC /EN 60947-2 and CE standards and used for protecting the circuits which have different characteristics like cable, motors, lighting, generators ...
SIGMA ELEKTRIK
Primary current: 3,000, 4,000, 6,000 A
VDC: 750 V - 1,800 V
... Entec's DC High-Speed Circuit Breaker (HSCB) symbolizes our advanced technology in DC interrupting. Entec's HSCB(EDB-09 and EDB-18) is used to manage DC Power Feeding line and interrupts the fault current. EDB-09 has ...
Primary current: 800 A
VAC: 12 kV
... Rated short- circuit breaking current - ≤ 20 kA Rated short-time withstand current 4s - ≤ 20 kA Rated frequency - 50/60 Hz Mechanical endurance - 50 000 CO cycles Temperature range - -40...+55 °C* Weight - 34 ...
TAVRIDA ELECTRIC NORTH AMERICA
Primary current: 6 A - 800 A
VAC: 400, 690 V
... the circuit of AC 50/60Hz, rated insulating voltage 690V (630 type is 500V), rated working voltage up to 690V, and rated current from 6A-800A in distribution line for distributing power, protecting line, ...
Radin Electric Technology Co., lTD
Primary current: 400 A - 3,150 A
VAC: 0.03 kV
VDC: 110, 220, 24, 48 V
... power plants, chemical/steel plants and construction facilities. It is a new-conceptual circuit breaker with short arc time and interruption time due to short- circuits and ground failure, which aims for ...
VitzroEM Co., Ltd.
Primary current: 45,000 A
VAC: 230, 415 V
VDC: 60 V
... miniature circuit breakers have been designed for protection of electrical installations against overload and short circuits and are manufactured in accordance with IEC 60898-1 Technical Data • Handle ...
IMO Precision Controls Limited
Primary current: 1 A - 40 A
... requirement for protection against overload and short circuit for all domestic, commercial and any low voltage distribution systems. · Only 18mm for 2P and 36mm for 3P+N/4P · Overloaded and short circuit ...
WENZHOU RENA ELECTRIC CO.,LTD
... Low Voltage Breakers Catalogue No. ’05-G90E Terasaki has a full range of Moulded Case Circuit Breakers from 30A to 4000A, and Air Circuit Breakers from ...
VAC: 72.5 kV
... Transmission , Distribution and Substation 72.5KV Live Tank SF6 Circuit Breaker ...
Primary current: 630, 1,250, 2,000 A
VAC: 12 kV
... The BSR is an OEM designed retrofit circuit breaker for both the BRUSH Switchgear VSI range of Oil Circuit Breakers and the VMV vacuum Circuit Breaker, ...
Primary current: 4,000 A
VAC: 12 kV
... up to 4000A. The circuit breaker conforms to GB 1984-2014 "High Voltage AC Circuit Breaker", JB/T 3855-2008 "3.6~40.5kV Indoor AC High Voltage Vacuum ...
Zhuhai Comking Electric Co.,Ltd.
Primary current: 0.1 A - 50 A
VAC: 415, 250, 240, 80, 32 V
VDC: 80, 65 V
... Vibrations: IEC 68-2-6 Mil-std 68-2-3 Umidity: IEC 68-2-6 Mil-std 68-2-3 Note Single or multipole small size circuit breaker, handle, rocker or sealed mount toogle, also available with snap-in mounting, ...
COMESTERO SISTEMI
VAC: 660, 690 V
... sensor .the circuit breaker can be used as an isolator with the mark The circuit breaker complies with the requirements of the standards GB140482″Low voltage switchgear ...
Primary current: 400 A - 2,000 A
VAC: 400, 690 V
... marine type and 1E circuit breakers, circuit breakers with low temperature of up to -40℃, as well as LCD and LED display circuit breakers. • Intelligence, ...
Primary current: 0 A - 1,600 A
VAC: 550, 800 V
... of a circuit breaker provides the feature of inverse time-delay, while the magnetic release is the instantaneous operation as shown on table 2(distribution circuit breaker) and table ...
Andeli Group Company
... ZW32 outdoor High Voltage AC Vacuum circuit Breaker is a new generation outdoor vacuum circuit breaker researched and developed recently based on the foreign advanced ...
Primary current: 40 A
VAC: 240 V
VDC: 50 V
... Circuit Breakers, Thermal, Series Trip, Silver, Operating Voltage 240 VAC, Operating Voltage 50 VDC, 40A Current Rating, Potter & Brumfield W23-31 • Circuit Breaker ...
Primary current: 40 mA
VDC: 19 V - 30 V
Rating: 30 A
... Input voltage required to switch on the outputs, typ. - 19 Vdc Output data Output current (sum of all outputs) - 30 A Turn-on delay of outputs - 750 ms Overview Dimensions (WxHxD) - 52 mm x 124 mm x 130 mm Weight per unit ...
PULS GmbH
Primary current: 6,000 A
VAC: 230, 400 V
... SFB2A series circuit breakers are applicable for places with AC 50Hz or 60Hz, rated voltage of 400V and below, and rated current of 16A-80A. It is mainly used for overload and short- circuit ...
Primary current: 25 A
... 25А – automatic shutdown system voltage at the high voltage. Protection loss of neutral. It is used to protect electrical equipment, household, industrial and office equipment from accidents in the power grid. ver ...
Primary current: 5, 25, 15, 30 A
VDC: 65 V
... ICT snap in circuit breakers are designed to provide reliable, long lasting service where high voltage and current handling are required. Features & Benefits 5-, 10-, 15-, 25- and 30-Amp versions ...