OxyTrend is an Oxygen analyser based on electrochemical sensor. It can be configured as a 2-wire loop powered transmitter or, connecting further 2 or 3 wires, it can also have serial output RS485 ModBus RTU (in alternative or in addition to the analog 4-20 mA).
OxyTrend can integrate 9 alternative types of sensor, depending on the measure to be achieved (from low traces, up to 100%). All sensors are insensitive to the presence of many background gases and hydrocarbons, making this instrument suitable for a variety of applications.
Simple, reliable and cost-effective solution to measure O2 in extractive applications in safe and hazardous area (ATEX) Zone 1 / Zone 21
Measureable Gas
Oxygen [O2]
Main Features
High Performances
- Two-wire, loop powered 4-20 mA transmitter
- Four or five-wire connection in case of use of the RS485 serial interface or 4-20 mA + RS485 respectively
- ModBus RTU Master or Slave selectable by menu
- Connectable with the ADEV 8RO4DI external module by RS485 to have 8 relays output and 4 digital inputs
- Unique hardware for all wiring connection types
- Optical through-the-glass buttons allowing menu operation without opening the housing
- Graphical LCD Display with visualization in Auto-Range and possibility to switch to trend visualization
- Use friendly menu and intuitive interface
- High Accuracy Galvanic Sensors
- Microprocessor-based technology and inner routine of electronic zero autocalibration
- User selectable range
- The version for hazardous area application is Ex-Proof and doesn’t require any Zener barrier in non-hazardous location
- Low Maintenance
- Sensor lifetime indication
- NAMUR error indication