The Simple Logger® II Model L562 is a two channel Volt/Amp data logger. The choice of data storage modes and storage rates allows the operator to effortlessly configure the logger to optimize memory usage to the application at hand. Extended Recording Mode XRMTM and delayed start time are just two of the many application friendly features. The Simple Logger® II records TRMS at a rate of up to eight times per second. The measurement process is performed no more than eight times per second. TRMS calculations are performed on a single line cycle. This means that the inputs are ignored between measurement intervals.
Specifications
Channels - Two
Connection - Current Channel - Voltage channel
Input - BNC - 4 mm safety banana jacks
Ranges (2) - 0 to 1 V for use with current probe with mV output - 5 to 600 VAC
Accuracy (50/60Hz) - (10 to 50) mV: ±(0.5% R +1mV)
(50 to 1000) mV ±(0.5% R +0.5mV) - (5 to 50) V: ±(0.5% R +1V)
(50 to 600) V: (0.5% R +0.5V)
Resolution - 0.1 mVAC - 0.1 VAC
Maximum Input Voltage - 5 rms or ±7.07 VPeak - 1.2 x 600 Vrms or 720 Vrms
Input Impedance - 800 kΩ - 40 MΩ
Sample Rate - 64 samples / cycle
Storage Rate - Programmable from 125 ms to 1 per day
Storage Modes - Start/Stop, FIFO, extended mode (XRM) and Alarm
Recording Length - 15 minutes to 6 weeks, programmable using DataView
Memory - 240,000 measurements (512 kB). Recorded data is stored in non-volatile memory and will be retained even if battery is low or removed.
Communication - USB 2.0 optically isolated
Power Source - (2) 1.5 V AA (LR6) alkaline batteries
Battery Life - 100 h to >45 d (depending on sample rate/recording length)