Key features- Long-range open-path monitoring for methane
- Continuous, real-time concentration measurement
- High selectivity to methane; resistant to interference from other gases, water vapour and dust
- IP66 protection, corrosion- and drop-resistant construction
- Aspherical lens design with infrared transmittance enhancement film
- Optional built-in Bluetooth module for real-time mobile APP communication
Product descriptionThe MIC600-TDL-CH4 is a tunable diode laser (TDL) open-path detector designed for continuous, long-distance monitoring of methane concentration in industrial and environmental applications. Compared with point detectors, it provides wider spatial coverage and faster identification of gas plumes. The system comprises an optical probe, a controller and a reflector. The optical probe integrates a laser collimator and detector; the controller houses laser drive, isolated power conversion, microcontroller and digital signal output circuits. The reflector surface is treated with a specialised coating to ensure reliable optical return and durability.
Applications- Petroleum and gas facilities
- Chemical plants
- Pharmaceutical production
- Environmental monitoring
- Gas distribution networks
- Flue gas analysis
- Air treatment systems
- Any site requiring continuous gas concentration profiling
Technical specifications- Model: MIC600-TDL-CH4
- Main material: 316 stainless steel casting
- Surface treatment: black brushed oxidation
- Operating temperature: -40℃ ~ 70℃, ≤98% RH (non-condensing)
- Response time: ≤5 s
- Explosion-proof mark: Ex ib IIC T4 Gb
- Detection range: 0 ~ 100000 ppm·m
- Product weight: approx. 5 kg
- Overall dimensions: Controller 185 mm × 119 mm × 61 mm; Optical probe Ø 180 mm × 88 mm (external)
- Detection target: Methane (CH4)
- Power consumption: <2 W (@24 V room temperature); <6 W (@24 V full temperature range)
- Optical power: <20 mW
- Display error: (0–1000) ±50 ppm·m
- Output signals: Active alarm, RS485, relay interface
- Storage temperature: -40℃ ~ 70℃
- Working pressure: 68 kPa ~ 115 kPa
- Working humidity: ≤98% RH (non-condensing)
- Supply voltage: 220 V AC
- Laser safety: Class III R