• Products
  • Catalogs
  • News & Trends
  • Exhibitions

Voltage calibrator EJB 9970
currentcompact

voltage calibrator
voltage calibrator
Add to favorites
Compare this product
 

Characteristics

Measured physical value
voltage, current
Options
compact
Temperature

Max.: 55 °C
(131 °F)

Min.: -10 °C
(14 °F)

Voltage

Max.: 100 mV

Min.: 20 mV

Description

EJB 9970 Volt / mA CALIBRATOR The EJB 9970 Volt/ mA Calibrator for measuring 0 to 24 mA DC current loop (with very high accuracy of 0,015%) or 0 to 20 V DC voltage, it delivers outstanding performance, durability and reliability. With a push button EJB 9970 is easy to use. It is EMI tolerant, dust and splash resistant, and features a removable battery door for quick battery changes. It is compact, lightweight, and easy to carry. Display : large (64 x 42 mm) 5 digit LCD DC voltage input & output : 0-100,00 mV DC voltage accuracy : ± 0,02% + 3 counts DC current input & output : 24,000 mA DC current accuracy : ± 0,015% + 3 counts Loop power output 24V ± 10% Input impedance : 2M Over voltage protection : 30V Voltage driver capability : 1 mA Fuse : 125 mA / 250 V fast acting fuse External power operation Dimensions : 205 x 97 x 45 mm Weight 460 g (incl. battery)

Other BERCU products

Products

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.