Unit for quick and precise leak testing of vacuum tight series components and helium recovery
Special features
■ Filling of the test object with helium inside the chamber (integrated gas handling)
■ Built-in calibration reference leak
■ Evacuation of the chamber
■ Test time approx. 5 minutes
■ Integrated helium recovery
■ Manual sliding door with pneumatically controlled door lock
■ Automatic control and colour touch panel with PC connection
Technical data
- Leak detection system: mass spectrometer
- Smallest detectable leak rate of the leak measurement system: 1x10-11 mbar l/s
- Chamber size: approx.: 1.3 m³
- Pumping performance: 500 m³/h with final vacuum 1x10-3 mbar
Application examples
Automotive industry
- Common rail injection systems and fuel pumps
- Oil and cooling circuits on cylinder blocks and cylinder heads
- Refrigerant vessels and cooling hoses
- Components of brake systems etc.
Refrigeration and air-conditioning technology
- Heat exchangers, refrigerant hoses, air-conditioning compressors, evaporators, air-conditioning lines, charge air coolers
Plant engineering
- Pumps, fittings, valves
Other fields of application
We recommend DILO helium leak testing units whenever a high tightness level of the components to be tested is required.