Earth-leakage protection relay DER3/2I
current2 NO/NCthree-phase

earth-leakage protection relay
earth-leakage protection relay
Add to favorites
Compare this product
 

Characteristics

Measured/monitored value
earth-leakage, current
Contact configuration
2 NO/NC
Network
three-phase, AC, single-phase
Applications
for three-phase motor pumps, for electric motors, for generators, for feeder, for transformers, transmission line, capacitor, for forklift trucks, for recloser controls, for pumps, emergency stop, switchgear, grid and system, for electric vehicle charging stations
Mounting
panel-mount
Reset
automatic reset, manual reset
Communication
RS485
Norms
IEC
Other characteristics
digital, programmable, configurable, differential, adjustable, electronic, smart
Tripping current

Min.: 0.03 mA

Max.: 30,000 mA

Trigger voltage

Min.: 48 V

Max.: 400 V

Description

DER3/2I - 2 thresholds - recessed 96x96mm The DER3 series differential toroid relays can be used on TT and TN type LV AC networks. They make it possible to achieve adequate selectivity and differential protection thanks to the wide regulation of the leakage current threshold (0.03÷30A) and of the trip delay threshold (instantaneous÷15 seconds). The DER3s comply with the stringent regulations in force (IEC 60947-2:2019) thus satisfying a dual need: system safety and service continuity. Dossena offers a complete range of differential relays rich in functions. New technology, ease of use, great reliability, ease of installation and programming, performance and "user friendly" design. The quantities and parameters are displayed on a large, very bright dot matrix display which changes color in relation to the operating status of the instrument (Green=measurement/monitoring, Blue=programming, Red=alarm/intervention). - type A/AC - 2 trip thresholds (Trip + alarm) with 2 output contacts (NO-C-NC) - continuous check of the correct functioning of the opening coil - continuous check of the correct functioning of the D series toroidal transducer - self-diagnosis with description of the problem on the display - option: RS485 Modbus Standard RTU serial output (only version with code 9DER3/2IRS485 and code 9DER3/2ICCRS485)

Catalogs

No catalogs are available for this product.

See all of DOSSENA‘s catalogs
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.