Heat shrinkable boots suitable for use in a nuclear environment, insulates and protects electrical splices and termination on multi core cables.
Functional after 850 kGy cumulative dose
Rated for 600/1000V
High resistance to impact and abrasion, lined with thermoplastic adhesive
Boots for 2, 3, 4 and 5 way breakouts
Shrink ratio: 3:1
Continuous operating temperature: -40°C to 100°C
Shrink Temperature: 125°C
IEEE 383
IEC 62677-3-101
NF M 64-001
IEC 60068
LOCA/POST LOCA in accordance with RCC-E 2007 NF M64-001
Continous use in a nuclear environment, strain relief, sealing, insulable protection on LV cable
Boots are qualified for use in zones K1, K2 and K3 according to NF M 64-001