In-plant Holiday Detector ISOTEST® act 8.0 / 35
... always the right pulse
■ test voltage 0.5 - 8.0 kV, 0.5 kV steps (ISOTEST® act 8.0)
■ or 7.5 - 35 kV, 2.5 kV steps (ISOTEST® act 35)
■ high-voltage pulse technology
■ no static charging
■ testing of dirty, damp and even slightly conductive surfaces
■ up to 6 test channels – synchronisation of several devices (master / slave mode)
■ “Phantom-Grounding” – no direct grounding necessary
■ external switch-on / switch-off of the test voltage
■ adjustable sensitivity and filter functions
ISOTEST® act 8.0 (0,5 - 8,0 kV, incrément 0,5 kV)
N° d’art. 0118100014
ISOTEST® act 35 (7,5 - 35 kV, incrément 2,5 kV)
N° d’art. 0111000004
Features
Non or slightly conductive materials and coatings such as 3 layer PE / PP can reliably be tested for holidays or other damage. The same goes for foils and rubber coatings to which this non-destructive testing with a minimum of material stress applies as well.
You can count on ...
■ a compact “all-in-one” device (control unit and high voltage generator in a single compact housing)
■ continuous operation (three shifts)
■ porosity / leak testing of all non or slightly conductive materials
■ external switch-on / switch-off of the test voltage
■ increased operator safety – thanks to the combination of impulse voltage and smart power control
■ stable test voltage, even under demanding conditions, guaranteed by load-dependent regulation of energy
■ high testing speeds made possible by optimised pulse repetition frequency
■ detection and display of even the smallest holidays and voids by the integral evaluation process – with minimal material stress
■ electrostatic charges – a latent risk for DC devices – are excluded by the use of impulse technology when properly grounded
■ testing of fully coated test objects – even without direct grounding – enabled by the option of “Phantom-Grounding”
All ISOTEST® holiday detectors have undergone extensive tests in the field of safety and EMC. They all carry the CE label and fulfil the requirements of all relevant standards and specifications (DIN EN / ISO / DVGW etc.)
Technical data
Test voltage
0.5 - 8.0 kV in steps of 0.5 kV (ISOTEST® act 8.0)
7.5 - 35.0 kV in steps of 2.5 kV (ISOTEST® act 35)
alternative test voltage ranges upon request
Test channels
up to 6 test channels (master / slave mode)
Voltage supply
100 – 240 VAC / 47 – 63 Hz (wide-range input)
or 90 – 375 VDC
Power supply (load-dependent)
< 100 W
Inputs
external activation of the test voltage via switch contact or 24 VDC
Outputs
floating change-over for detection alarm
floating change-over for operational monitoring
Operating time
continuous operation (three shifts)
Testing speed
up to 1200 mm/s
Stabilisation of the test voltage
load-dependent regulation (continuous)
Load adaptation
selectable filter settings for optimum adaptation to individual test conditions
Indication of porosity
display indication
potential-free contact for external signalling units
Further display options
detection counter
multilingual menu
operating time counter (per operation & total)
indication of the next scheduled service date
Permissible ambient temperature
0° C ... +50° C (thermal constant > 10 K/h)
Air humidity
max. 60 % relative air humidity at 30° C
Housing dimensions (W x D x H)
380 x 210 x 300 mm
Weight
12 kg
Revisions in the course of technical progress reserved.