EDT2411A is a temperature controller has NTC probe input, single relay output. Compressor protection parameters can be entered. The measurement temperature range is between -60.0...+150.0. Without energy to the device can be tranferred parameter with "ENDAKEY". Optionally, with RS485 Modbus protocol communication feature. Making defrost and energy-saving feature with RTC (Real Time Clock).
Outputs
Life expectancy for relay - For EDT2411-X-P ; Without load 10.000.000 switching;
277V AC,20A (for resistive load) 100.000 electrical operation.
Control
Dimensions - W77xH35xD61 mm
Mounting - Suitable for flush-panel mounting
Weight - Approx. 190 g (After packing)
On-Off control
Relay output for cooling or heating control
Single NTC probe input
Offset value can be adjusted for NTC probe
Compressor protection parameters can be adjusted
In the case of probe failure, output state can be selected as on-off or periodical running
Upper and lower limits of the set point can be adjusted
Selectable “Smart Defrost” feature
Defrosting duration and interval can be adjusted
6 different warning tones
Upper and lower limits of the alarm value can be adjusted depending on the set point value
Temperature unit can be selected as °C or °F
External alarm can be given by using digital input
Defrosting can be started by using digital input
Parameter can be transferred by using “ENDAKEY” without connecting the device to mains supply
Communication feature via RS485 ModBus protocol (order option)
CE marked according to European Norms