video corpo

Digital multimeter 8808A
benchtop1000 V10 A

Digital multimeter - 8808A - Fluke Calibration - benchtop / 1000 V / 10 A
Digital multimeter - 8808A - Fluke Calibration - benchtop / 1000 V / 10 A
Digital multimeter - 8808A - Fluke Calibration - benchtop / 1000 V / 10 A - image - 2
Digital multimeter - 8808A - Fluke Calibration - benchtop / 1000 V / 10 A - image - 3
Digital multimeter - 8808A - Fluke Calibration - benchtop / 1000 V / 10 A - image - 4
Add to favorites
Compare this product

Characteristics

Display
digital
Form
benchtop
Max voltage
1000 V
Max current
10 A
Safety rating
cat I
Additional features
frequency, with leakage current measurement
Applications
industrial, service, R&D
Other characteristics
high-precision, high-resolution, low-impedance, connectivity, USB, with PC interface
Max DC voltage

Max.: 1,000 V

Min.: 0.2 V

Max AC voltage

Max.: 750 V

Min.: 0.2 V

Max DC current

Max.: 10 A

Min.: 0 A

Max AC current

Max.: 10 A

Min.: 0.02 A

Max resistance measure

Max.: 100,000 kOhm

Min.: 0 kOhm

Max frequency measure

Max.: 1 MHz

Min.: 0 MHz

Max DC voltage resolution

0.001 mV

Max AC voltage resolution

0.001 mV

Max DC current resolution

0.000001 mA

Max AC current resolution

0.1 mA

Max resistance resolution

0.001 Ohm

DC voltage precision

0.02 %

Length

297 mm
(11.69 in)

Width

217 mm
(8.54 in)

Height

88 mm
(3.46 in)

Weight

2,100 g
(74.08 oz)

Description

Product overview
The Fluke 8808A is a bench digital multimeter designed for manufacturing, R&D and service environments. It provides 5.5‑digit resolution, a dual reading display and dedicated low‑leakage DC current measurement, enabling repeatable, high‑resolution voltage, resistance, current and frequency measurements with built‑in limit comparison for pass/fail checks.

Key features
  • 5.5 digit resolution
  • Basic DC voltage accuracy 0.015%
  • Dual display for simultaneous measurement of two related parameters
  • Dedicated DC leakage current measurement using low‑impedance I→V technique (high sensitivity)
  • 2 x 4‑wire resistance measurement (4‑wire functionality using two leads)
  • Six front‑panel programmable setup keys (S1–S6) for fast recall
  • Hi/Lo limit compare with pass/fail indicators
  • RS‑232 and USB (with optional adapter) interfaces; FlukeView Forms Basic support
  • Three‑year warranty


Models / Included items
  • Model: Fluke 8808A
  • 5.5 digit bench multimeter
  • TL71 test leads
  • Line cord
  • USB to RS‑232 interface adapter cable
  • FlukeView Forms Basic software (CD)
  • Statement of calibration practices and user documentation (Getting Started guide in multiple languages)


Technical specifications
  • Display: VFD multi‑segment dual reading
  • Resolution: 5.5 digits
  • DC volts: 200 mV to 1000 V; max resolution 1 µV; accuracy 0.015 + 0.003
  • AC volts: 200 mV to 750 V; max resolution 1 µV; accuracy 0.2 + 0.05; frequency 20 Hz–100 kHz
  • Resistance: 2 x 4‑wire support; 200 Ω to 100 MΩ; max resolution 1 mΩ; accuracy 0.02 + 0.003
  • DC current: 200 µA to 10 A; max resolution 1 nA; accuracy 0.02 + 0.005
  • AC current: 20 mA to 10 A; max resolution 100 µA; accuracy 0.3 + 0.06; frequency 20 Hz–2 kHz
  • Frequency: 20 Hz to 1 MHz; max resolution 0.1 mHz; accuracy 0.01%
  • Math: dB/dBm supported
  • Advanced: limit compare (Hi/Lo) with pass/fail indicators
  • Interfaces: RS‑232; USB with optional adapter
  • Programming: Simplified ASCII; Fluke 45 remote command emulation
  • Weight: 2.1 kg
  • Dimensions (H x W x D): 88 x 217 x 297 mm
  • Safety: complies with EN 61010‑1, ANSI/ISA 61010‑1, UL 61010‑1, CSA C22.2 No. 61010.1
  • Calibration: Statement of calibration practices included; calibration report optional
  • Warranty: 3 years

Catalogs

No catalogs are available for this product.

See all of Fluke Calibration‘s catalogs
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.