Sterility testing containment isolator STI4, STI4c
floor-mountedpositive pressurestainless steel

sterility testing containment isolator
sterility testing containment isolator
sterility testing containment isolator
sterility testing containment isolator
sterility testing containment isolator
sterility testing containment isolator
Add to favorites
Compare this product
 

Characteristics

Applications
for sterility testing
Configuration
floor-mounted
Other characteristics
positive pressure, stainless steel

Description

Sterility Testing Isolators with product protection for sterility testing under aseptic conditions. Optionally, a rapid decon hatch can be connected. Product protection is achieved by means of a barrier (isolator housing with glove ports) between the operator and the product. The laminar air flow system, incl. monitored positive pressure control, increases the level of safety for the product. Products and material are transferred inwards and outwards via a suitable transfer system. The isolators are decontaminated with vH2O2 (vaporized H2O2) before the sterility test by means of the integrated Bio-Decontamination-System ‘FZ-BDS 12/60’. All safety-relevant functions are constantly monitored electronically. Technical Details Sterility Testing Isolator STI4 •Fully welded stainless steel housing in a single-wall construction and return air ducts with radial edges and rounded corners •Folding, electrically monitored, front panel of safety glass with pneumatic springs, pressure-controlled pneumatic seals and glove ports (glove material: CSM) •Integrated sterility test pump (tbd) •Shelving systems for storing consumables •Laminar air flow recirculation system and positive pressure control by means of supply and exhaust air units •Gas-tight, electrically operated butterfly valves on the supply air and exhaust air side •Integrated Bio-Decontamination-System ‘FZ-BDS 12/60’ with vH2O2 directly injected (DIS = direct injection system) below the membrane distributor for an effective and stable decontamination process with short cycle times •Integrated catalysts for flushing after vH2O2-decontamination (no connection to the on-site ventilation system required)

Exhibitions

Meet this supplier at the following exhibition(s):

ACHEMA 2024
ACHEMA 2024

10-14 Jun 2024 Frankfurt am Main (Germany) Hall 3.0 - Stand A38

  • More information
    *Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.