Analog signal conditioner X1-IS-AO-02-S
4-20 mAprogrammableisolated

Analog signal conditioner - X1-IS-AO-02-S - GM International S.p.A. - 4-20 mA / programmable / isolated
Analog signal conditioner - X1-IS-AO-02-S - GM International S.p.A. - 4-20 mA / programmable / isolated
Analog signal conditioner - X1-IS-AO-02-S - GM International S.p.A. - 4-20 mA / programmable / isolated - image - 2
Add to favorites
Compare this product

Characteristics

Signal type
analog, 4-20 mA
Options
programmable, isolated

Description

The Isolating Driver X1-IS-AO-02 module is a high integrity analog output interface suitable for applications requiring SIL 2 level in safety related systems for high risk industries. It isolates and transfers a 4-20 mA signal from a controller located in Safe Area to a load in Hazardous Area. The circuit allows bi-directional communication signals, for HART® smart positioners. Line and load open/short circuit detection is provided: the fault in the field is directly mirrored to the PLC AO card as open circuit and it is also reported on the common fault line. To ease maintenance operations, field devices can be disconnected through a two-position insertion/extraction mechanism. This product requires a dedicated Termination Board.SIL 2 / SC 3Input from Zone 0 / Division 1Installation in Zone 2 / Division 2Loop disconnection to ease maintenance operationsHART® compatibleLine & Load short/open circuit programmable diagnosticsOut-of-range fault with programmable thresholdsField fault mirroring to the DCS/PLC IO CardHigh AccuracyThree port isolation, Input/Output/SupplyTechnical Specifications:Power Dissipation: 0.75 W @ 24 Vdc with 20 mA on I/P output, typical.System Supply Voltage: 24 Vdc nom (18 to 30 Vdc).Current Consumption: 30 mA @ 24 Vdc with 20 mA on I/P output, typical.System In Type: Current 4 to 20 mA.Input fault impedance: 16 kΩ @ 24 Vdc (input current 1.5 mA), typical.Field Out Type: Current 4 to 20 mA + HART.Maximum load: 600 Ω.Response time: 5 ms.Fault Type: Load short/open with settable limits on voltage, current and resistance.Fault signalling: common fault & fault mirroring on DCS/PLC IO.Reference Conditions: 24 V supply, 250 Ω load, 23 ± 1 °C Tamb.Calibration accuracy: ≤ ±20 µA.Linearity accuracy: ≤ ±20 µA.Temperature influence: ≤ ±2 µA/°C.Isolation Test Voltage: Field Out/System In 2.5 kV; Field Out/System Supply 2.5 kV; System In/System Supply 500 V.Operating temperature: –40 to +70 °C.Storage temperature: –45 to +80 °C.Equipment: Associated apparatus and non-sparking electrical equipment.Safety parameters: Uo = 26.7 V, Io = 92 mA, Po = 610 mW at terminals A-Z. Um = 250 Vrms or Vdc, -40 °C ≤ Ta ≤ 70 °C.Mounting: On custom Termination Board.Weight: about 50 g.Dimensions: Width 10 mm, Depth 80 mm, Height 120 mm.

Catalogs

No catalogs are available for this product.

See all of GM International S.p.A.‘s catalogs
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.