... Stainless Steel Enclosure, IP65 Protected • Output can Be Sent Over Much Longer Distances than Millivolt Signals The OMEGA IN-UVI in-line signal conditioner is housed in a rugged ...
For RF and microwave measurements, PXI multi-channel signal conditioners modify an analog signal to meet the requirements of the next stage for signal ...
... Optional MODBUS (RS-485) communication function can be obtained simultaneously with analog output signal from one VJ. Alarm outputs* Bi-directional relay of HART communication signals ...
... 5/7 ms for analog signals and less than 30 ms for temperature measurements) lowering downtime • Simplifies troubleshooting by onboard sensor and signal error indication • Provides ...
... absolutely measuring unit with hard-wired sensor Maintenance-free backup battery Option: digital LD interface Option: analog 1 VSS interface (period length 1 mm) Mechanical data Feature - Technical data - - Additional ...
... hard-wired sensor Max. measuring length ±655 m (RS485) Maintenance-free backup battery Option: digital LD interface Option: analog 1 VSS or 2.2 VSS interfaces (5 mm period length) Mechanical data Feature - Technical ...
... intended for load measurement. The device includes strain gauge bridge input and a voltage input to allow summation of the two signals when needed. The unit can be supplied at 115 V AC/ 230 V AC or at 20, 32 V DC based ...
... low amplitude signals to industrial programmable logic controllers (PLC). The LMU conditioners can easily be connected to the GADSeries and ANSeries signal displays. The LMU 209 is ...
The TSC Series is the Torque and Speed Conditioner used to connect Magtrol Eddy-Current (WB) or Powder (PB) Dynamometers to the DSP7000 Dynamometer Controller. Powered by the dynamometer controller, and based on a precision ...
Strain gage conditioner ± 10 V / 0-10 V - 4-20 mA • Analog signal conditioner • Presentation in rail DIN housing, IP65 housing or single board • Able ...
... Basic version with fixed output range, voltage or current output The MUP 080 signal processing unit from Novo Technik is made to provide precise measurements. This is an analog unit that is used for applications ...
... connect to any cable and measurement system at the installation site. With A-Box-T Signal Converter, the sensor cable can also be extended over a long distance without any signal loss or potential electromagnetic ...
ST-VA Volt / Current Conditioner ● Measuring Voltage or Current for DC / AC / TRMS ● Accuracy: ± 0.04% or ± 0.1%; Display range: -19999~29999 ● User function, easily programmable via the top panel ● 1 Analogue ...
... choices Push Button User Trim For In Process Fine Tuning Galvanic Isolation The SEM1620 signal conditioner provides a 3 wire isolated voltage output signal and accepts RTD, Thermocouple, ...
... Segment User Linearisation Sensor Offset and Output Alignment Adjustable Input Filter The SEM1600T accepts resistance or mV signals from RTD, Slidewire or Thermocouple sensors. Other sensor characteristics or your ...
The PT100LC is a basic load cell conditioner with pre-set filtering and analogue output. It is easily mounted in control cabinets and connected to equipment with analogue input. Specifications Power ...
... PT112LC are DIN rail mounted micro-controller based analogue load cell transmitters. They have very high accuracy and long term stability with advanced design. Using an up to-date delta-sigma ADC and ...
The TMvL2 is an analog signal converter equipped with SIL2 safety analog and relay outputs. Mounting in a cabinet: latching on a symmetrical DIN rail. TECHNICAL SPECIFICATIONS ANALOG ...
ARDETEM SFERE
The TMvL3 is an analog signal converter equipped with SIL3 safety analog and relay outputs. Mounting in a cabinet: latching on a symmetrical DIN rail. TECHNICAL SPECIFICATIONS ANALOG ...
ARDETEM SFERE
... TECHNICAL SPECIFICATIONS Marking: II 3 (1) G Ex ec nC [ia Ga] IIC T4 Gc Bidirectional I.S. input: mA, mV, V 1 analog output: voltage or current (active/passive) Accuracy: 0.1% Scale factor programmable ...
ARDETEM SFERE
... sensors require a basic electrolytic tilt sensor circuit to generate a tilt angle output. These are often called signal conditioners, signal conditioning boards, or electronic tilt sensors. ...
The Fredericks Company
... WITH A/D CONVERTER Our multi-channel signal conditioning modules provide separate A/D conversion on each channel and up to 24-bit resolution with anti-aliasing filters. Perfect simultaneous sampling for all analog ...
DEWETRON GmbH
Model A1 Analogue Sensor Signal Conditioner (SSC) is designed as a low profile SSC to be used with any sensors which are built with Wheatstone bridge circuit. It amplifies an input (i/p) ...
... State-of-the-art signal conditioning Provides six independently configurable data channels Fully calibrated and NIST-traceable Signal conditioning includes: 1 kHz anti-aliasing filters, ...
Advanced Mechanical Technology
Integrating Charge / IEPE Amplifiers Application • Signal conditioning for dynamic measurement with piezoelectric sensors for acceleration, force and pressure or sound • Front-end with anti-aliasing filter for PC ...
Metra Mess- und Frequenztechnik in Radebeul e.K.
CDV-400B series is a multi-channel signal conditioner system to measure physical quantity such as strain,acceleraton, load, voltage and frequency. The compact and lightweight design makes the system suitable ...
APPLICATIONS Conditioning of any kind of analog signal coming from a sensor to fit with data acquisition systems or Programmable Logic Controller (PLC) Electrical and physical measurement: strength, ...
CELIANS
... in zone 2 SIL 2 Country of origin - DE Weight - 115 g Technical Data Signal type - Analog output (HART transparent) Device type - Analog signal ...
... the signal conditioner line. The SC-System offers powerful modules for analog and digital measuring signals – from the isolating amplifier to the highly functional ...
... absolute reliability. WAGO's frequency signal conditioner collects 0.1–120 kHz signals from NAMUR, NPN or PNP sensors and converts them into a standard analog signal. ■ ...
With the IMX, WayCon Positionsmesstechnik offers a device that quickly converts input signals (position, frequency, SSI and speed) into absolute analog values. The analog variables of ...
The SGA series signal conditioners are ideal for cyclic and high speed testing where no display is needed. Available in single and dual channel versions, they provide the signal conditioning ...
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining