Strain gauge load cells conditioner with digital weight transmission via RS485 serial interface The WTD3 is a strain gauge load cells conditioner with digital weight ...
The TD-SC1 is a signal conditioner which converts a minute electrical signal of a load cell into an output that matches the specifications of the control unit. This product is mainly ...
... (RS-485) communication function can be obtained simultaneously with analog output signal from one VJ. Alarm outputs* Bi-directional relay of HART communication signals is possible while the field devices ...
Max. resolution 0.2 μm (LD) Repeat accuracy ±5 μm SSI or RS485 interface Scale MBA110 Reading distance ≤0.4 mm Compact, absolutely measuring unit with hard-wired sensor Maintenance-free backup battery Option: analog 1 VSS interface ...
... absolutely measuring unit with hard-wired sensor Max. measuring length ±655 m (RS485) Maintenance-free backup battery Option: digital LD interface Option: analog 1 VPP or 2.2 VPP interfaces (5 mm period length)
... /4 … 20 mA current output 1 x fail safe relay 2 x operating relay Ambient temperature -20 ... 60 °C Signal input (specify) 4 … 20 mA Signal output (specify) 4 … 20 mA Operating relay Fail safe ...
VEGA TECHNIQUE
... x operating relay 1 x fail safe relay 1 x Ethernet or 1 x RS232 Ambient temperature -20 ... 60 °C Signal input (specify) 4 … 20 mA/HART Signal output (specify) 4 … 20 mA Operating relay Fail ...
VEGA TECHNIQUE
... Ethernet 1 x RS232 3 x operating relay 3 x 0/4 … 20 mA current output Ambient temperature -20 ... 60 °C Signal input (specify) 4 … 20 mA/HART Signal output (specify) 4 … 20 mA Operating relay Fail ...
VEGA TECHNIQUE
... controller. Provides an inexpensive solution for digitally recording extensometer output. The DSCUSB is a signal conditioner that provides a digital interface to a computer via ...
MODBUS 485 RTU Digital Signal Conditioner The MC-20 converter is a digital signal conditioner designed to convert the voltage output ...
ST-PR Process Conditioner (11 PIN Plug) ● Measuring linear signal 0~10V / 0(4)~20mA in one controller ● Accuracy: ± 0.04%; 4 1/2 Digital display: -19999~29999 ● User function, Easily ...
... Transmmiter incorporating advanced state-of-the-art PAC technology. This Signal Conditioner converts Thermocouples, RTD, mV, mA and electric variables AC, DC, RMS, Hz or Ohms signals ...
... basic electrolytic tilt sensor circuit to generate a tilt angle output. These are often called signal conditioners, signal conditioning boards, or electronic tilt sensors. ...
... interfaces with a wide variety of sensors and provides an analog signal directly proportional to the speed of a monitored shaft. The voltage outputs can be sent to a chart recorder, digital display, PLC, ...
... State-of-the-art signal conditioning Provides six independently configurable data channels Fully calibrated and NIST-traceable Signal conditioning includes: 1 kHz anti-aliasing filters, ...
... optical signal and its analysis. This Myotis1300 version also allows signal amplification with a gain on 3 levels, the use of headphones and the BNC AC output, an SMA DC output for monitoring the integrity ...
... the signal conditioner line. The SC-System offers powerful modules for analog and digital measuring signals – from the isolating amplifier to the highly functional ...
With the IMX, WayCon Positionsmesstechnik offers a device that quickly converts input signals (position, frequency, SSI and speed) into absolute analog values. The analog variables of current and voltage can be scaled ...
Compass SC1 & SCD1 - NEW "All-in-One" Signal Conditioner Solartron’s new signal conditioner accepts any standard LVDT or Half bridge analogue probes with 5 Pin DIN connectors. ...
Compass SC1 & SCD1 - NEW "All-in-One" Signal Conditioner Solartron’s new signal conditioner accepts any standard LVDT or Half bridge analogue probes with 5 Pin DIN connectors. ...
... service in the various versions the new MP6Plus is born. MP6Plus is a Professional Digital Laboratory Indicator with 1, 2, 3, or 4 inputs, suitable for receiving signals from strain gauge sensors, ...
... sensors; 1 make contact; Digital output; Configuration via software; Supply voltage: 24 VDC; 12.5 mm module width; Railway WAGO's RTD threshold value switch for RTD sensors, potentiometers and resistors monitors and ...
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining