SIL2 universal transmitter X1-IS-UNI-01-S
DIN rail

SIL2 universal transmitter - X1-IS-UNI-01-S - GM International S.p.A. - DIN rail
SIL2 universal transmitter - X1-IS-UNI-01-S - GM International S.p.A. - DIN rail
Add to favorites
Compare this product

Characteristics

Type
DIN rail, SIL2

Description

The Universal X1-IS-UNI-01 module is a high integrity interface suitable for applications requiring SIL 3 or SIL 2 level (depending on applications) in safety related systems for high risk industries. Thanks to its high flexibility, it can interface 2-wire active/passive 4-20 mA (AI), smart positioners (AO), switches and proximity detectors (DI), as well as solenoid valves and other process control devices (DO) located in Hazardous Area. HART® communication is supported for both active and passive transmitters, and I/P. The module always sinks current and the Termination Board extends its use to source loops. Programmable line and load open/short circuit detection and out-of-range current fault is also provided. The module automatically matches the application, without reprogramming; if required, it can be re-calibrated through the configuration software. To ease maintenance operations, field devices can be disconnected through a two-position insertion/extraction mechanism. This product requires a dedicated Termination Board. - SIL 3/2 depending on applications / SC 3 - Input from Zone 0 / Division 1 - Installation in Zone 2 / Division 2 - Loop disconnection to ease maintenance operations - Suitable for AI, AO, DI and DO applications without configuration - HART® compatible (passive and active AI/AO loops) - Line & Load short/open circuit programmable diagnostics - Out-of-range fault with programmable thresholds - Digital calibration available through configuration software - Input and Output short circuit proof - Field fault mirroring to the DCS/PLC UNI Card - High Accuracy - Three port isolation, Input/Output/Supply Technical Specifications: - AI Power dissipation: 0.90 W (pass. Tx), 1.05 W (act. Tx) with 20 mA, 24 V + 250 Ω @ 24 Vdc, typical. - AO Power dissipation: 0.75 W with 20 mA on I/P out @ 24 Vdc, typical. - DI Power dissipation: 0.95 W with short circuit input @ 24 Vdc, typical. - DO Power dissipation: 1.60 W with 40 mA, 1.40 with 35 mA @ 24 Vdc, typical. - System Supply Voltage: 24 Vdc nom (18 to 30 Vdc). - AI Current consumption: 32 mA (passive Tx), 18 mA (active Tx) with 20 mA @ 24 Vdc, typical. - AO Current consumption: 30 mA with 20 mA on I/P out @ 24 Vdc, typical. - DI Current consumption: 30 mA with short circuit input @ 24 Vdc, typical. - DO Current consumption: 67 mA with 40 mA @ 24 Vdc, typical. - System In/Out Type: Current 0 to 40 mA, mirrored from Field. The module always sinks current and the Termination Board extends its use to source loops. - Response time: 5 ms. - Maximum load: 600 Ω (AI usage). - Minimum voltage: 15 V (AI, DI, DO usage). - Maximum voltage: 30 V (all applications). - Field In/Out Type: Field interface specs depend on terminals and usage. - Current limitation: 45 mA, typical, for all applications. - AI: Current 4 to 20 mA, passive or active Tx + HART. - AI Passive Tx line voltage: 15.5 V minimum @ 20 mA. - AI Active Tx voltage drop: 6.5 V maximum @ 20 mA. - AO: Current 4 to 20 mA + HART. - AO Maximum load: 600 Ω. - DI: 8 V/1 kΩ typical, according to NAMUR standard. - DO: 0 to 40 mA, linear derating from 40 mA (60 °C) to 35 mA at (70 °C). - DO Output voltage: 8.5 V minimum @ 40 mA. - Fault Type: Load short/open with settable limits on voltage, current and resistance. - Fault signalling: common fault & fault mirroring on DCS/PLC IO. - Performance Reference Conditions: 24 V supply, 250 Ω load, 23 ± 1 °C Tamb. - Calibration accuracy: ≤ ± 20 µA. - Linearity accuracy: ≤ ± 20 µA (4 to 20 mA), ± 60 µA (0 to 40 mA). - Temperature influence: ≤ ± 2 µA/°C. - Isolation: Field InOut/System InOut 2.5 kV; Field InOut/System Supply 2.5 kV; System InOut/System Supply 500 V. - Operating temperature: –40 to +70 °C - Storage temperature: –45 to +80 °C. - Equipment: Associated apparatus and non-sparking electrical equipment. - Safety parameters: Uo = 26.7 V, Io = 92 mA, Po = 610 mW at terminals A-Z. Uo = 10.7 V, Io = 11 mA, Po = 29 mW at terminals C-Z. Uo = 1.1 V, Io = 56 mA, Po = 16 mW at terminals B-Z. Ui = 30 V, Ii = 120 mA, Ci = 0.6 nF, Li = 0 µH at terminals B-Z. Um = 250 Vrms or Vdc, -40 °C ≤ Ta ≤ 70 °C. - Mounting: On custom Termination Board. - Weight: about 50 g. - Dimensions: Width 10 mm, Depth 80 mm, Height 120 mm.

Catalogs

No catalogs are available for this product.

See all of GM International S.p.A.‘s catalogs
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.