Catégory D1 /C1 /C2 /C3 surge protector D9520S

Catégory D1 /C1 /C2 /C3 surge protector - D9520S - GM International S.p.A.
Catégory D1 /C1 /C2 /C3 surge protector - D9520S - GM International S.p.A.
Catégory D1 /C1 /C2 /C3 surge protector - D9520S - GM International S.p.A. - image - 2
Catégory D1 /C1 /C2 /C3 surge protector - D9520S - GM International S.p.A. - image - 3
Add to favorites
Compare this product

Characteristics

Type
catégory D1 /C1 /C2 /C3
Voltage

24 V

Primary current

600 mA

Description

SIL 3 Surge Protective Device for Signal System Model D9520SD9520S provides two-stage surge protection for floating I/O three-wire signals of measurement and control and safety systems. With a width of 6mm, it can be easily fitted into any marshalling cabinets or distribution cabinets. It consists of a protective plug and a base element. The SPD provides surge protection with 1.65Ω loop impedance, with disconnect knife on both signal paths for easy testing of the loop.SIL 3 according to IEC 61508:2010.Input from Zone 0 (Zone 20), installation in Zone 1 and 2.Disconnection of signal circuit by disconnect knife.Signaling without additional auxiliary power, thanks to the mechanical status indicator.Signal not interrupted during maintenance work, thanks to impedance neutral insertion and removal of protective plug.High Density, 6.2 mm per channel.HART compatible.Technical DataSupplyNominal system voltage Un24 V DCMax continuous operating voltage Uc30 V DCRated current600 mA (40°C)ProtectionIEC test classificationC1 / C2 / C3 / D1Protection of signal types0/4-20 mA HART, Digital I/O, World FIP, F&GNominal discharge current (In)(8/20) μs: 5 kA (core-core) 5 kA (core-ground) 5 kA (core-earth)Impulse discharge current (Iimp)(10/350) μs: 0.5 kA (core-core) 0.5 kA (core-ground) 0.5 kA (core-earth)Total discharge current (Itotal)(8/20) μs: 10kAMax. total discharge current (Imax)(8/20) μs: 20kA (for one time)Series resistance1.65Ω ± 20%Voltage protection level (Up)≤ 150 V (C1 - 1 kV/500 A) core-core≤ 275 V (C2 - 10 kV/5 kA) core-core≤ 55 V (C3 - 100 A) core-core≤ 750 V (C1 - 1 kV/500 A) core-ground≤ 750 V (C2 - 10 kV/5 kA) core-ground≤ 1.2 KV (C3 - 100 A) core-ground≤ 80 V (C1 - 1 kV/500 A) core-earth≤ 125 V (C2 - 10 kV/5 kA) core-earth≤ 55 V (C3 - 100 A) core-earthResponse time tA≤ 1 ns (core-core) ≤ 1 ns (core-ground) ≤ 100 ns (core-earth)Environmental conditionsOperating temperaturetemperature limits –40 to +85 °C, relative humidity 5% to 95%.MountingTypeEN/IEC60715 TH 35 DIN-Rail.Weightabout 43 g.Connectionscrew terminal blocks to accommodate terminations up to 2.5 mm2 flexible.Locationinstallation in Safe Area or Zone 2 or Zone 1, Group IIC T4...T6.Protection classIP20.DimensionsWidth 6.2 mm, Depth 100 mm, Height 105.8 mm.CertificationsATEX: DEKRA ATEX D9410, D9420, D9510, D9520 Series English Certificate (Europe, BVS 18 ATEX E 018 X, DEKRA, 2022-07-12)IECEx: DEKRA IECEx D9410, D9420, D9510, D9520 Series Certificate (International, IECEx BVS 18.0012X, DEKRA, 2022-07-18)SIL: EXIDA GM 17/11-006 R008 Analysis for SIL Application D9510S, D9520S (International, GM 17/11-006 R008, EXIDA, 2018-03-28)Declarations of ConformityEU Declaration of Conformity for D9410, D9420, D9510, D9520Characteristics / Technical SpecificationsModel: D9520SCategory: Surge protection for I/O signals and SignalingWidth: 6.2 mmDepth: 100 mmHeight: 105.8 mmWeight: about 43 gMounting: EN/IEC60715 TH 35 DIN-RailProtection class: IP20Operating temperature: –40 to +85 °CRelative humidity: 5% to 95%Nominal system voltage: 24 V DCMax continuous operating voltage: 30 V DCRated current: 600 mA (40°C)Series resistance: 1.65Ω ± 20%IEC test classification: C1 / C2 / C3 / D1HART compatibleSIL 3 according to IEC 61508:2010

Catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.