Technical Specifications
Temperature Range70°C to 100°C
Dew Point Temperature Range7℃ to 87℃
Extended Dew Point Conditions -10℃
Humidity Range10%98% RH
Humidity Control±2.5%RH
Humidity Uniformity±1.0 % RH
Noise test≤ 68dB
1.Integral structure, the inner wall special process rolling molding, the whole using TIG seamless welding, beautiful appearance; Door lock device adopts lever power opening mechanism.
2.The use of Chinese color LCD touch man-machine interface + high-performance programmable controller (PLC), with TESTEQ test box special software, with automatic, intelligent, human control and other characteristics.
3.Control mode: constant operation mode, program operation mode.
4.Patented "static balance" technology, low temperature constant temperature season can be more than 30%.
5.Refrigeration compressor and key accessories are selected international and domestic well-known brands, long-term and reliable operation; Environmentally friendly refrigerant, in line with the requirements of international environmental protection conventions.
6.Configure RJ45 communication interface, remote control system (open data transmission protocol support Modbus/OPC).
7.Surface electrostatic powder spraying; Box color "TESTEQ White ", controller panel color "TESTEQ Blue ".
8.TESTEQ patent cold well adsorption anti-condensation function (optional).
Mainly used in aviation, aerospace, electronics, instrumentation, electrical products, materials, parts, complete machines and equipment for accelerated wet heat test, alternating wet heat test, constant wet test, It can also be used for high-low wet routine test, cold resistance test, low temperature storage, adaptability test under rapid temperature change or gradual change test of electrical and electronic products or for improving production efficiency.
Meet standard
GB/T 2423.1 (IEC60068-2-1); GB/T 2423.2 (IEC60068-2-2);
GB/T 2423.3 (IEC60068-2-78); GB/T 2423.4 (IEC60068-2-30) ;
GJB 150.3A; GJB 150.4A; GJB 150.9A;GB/T10589; GB/T10592;
GB/T11158; GB/T10586 GB/T 2423.16 (IEC60068-2-10);
GJB 150.10A; GB/T10588; GJB 150.7A