Fully Automatic Inverted Pressure Sterilized Boiler GZM-100G
This product adopts the radial self-expanding sealing structure with independent intellectual property rights of our company; the operation, control and display of the touch LCD screen are used, and the digital program control is realized in the state of man-machine dialogue through the microcomputer system; the equipment is equipped with a printer and a USB Interface, real-time printing and recording of key parameters of sterilization; equipped with back pressure and spraying device, which can effectively prevent the package from bursting and quickly cool down, and the cover is equipped with a pneumatic spring rod, which is convenient to open the cover.
Features
The container components and parts in contact with the sterilized materials are all made of high-quality stainless steel, manufactured through forming, argon arc welding, and polishing processes, offering advantages such as corrosion resistance and long service life.
The design and manufacture of the product body, lid, and safety accessories comply with the requirements of TSG21-2016 "Safety Technical Supervision Regulations for Stationary Pressure Vessels" and NB/T47052-2016 "Simple Pressure Vessels".
The radial self-expanding sealing structure used in this product is a technology with independent intellectual property rights, and the sealing ring is made of silicone rubber through molding.
The product has a device for internal cooling of process vented steam to prevent high-temperature steam from affecting the environment.
It adopts microcomputer control technology and uses a touch-screen LCD to create a user-friendly interface, dynamically displaying the operating procedures and running status.
The cooking pot has customizable programs; users can set the sterilization temperature and holding time on the touch-screen monitoring interface according to different sterilization targets, and the program is automatically memorized after setting.
The cooker features an automatic water replenishment function; once the water replenishment program starts, the inlet valve automatically opens to add water.
The touch-screen color LCD and pressure gauge are positioned at an angle perpendicular to the user's line of sight, making operation, observation, reading, and signal display very convenient and clear.
The cooker is equipped with a mini printer and a USB interface. After sterilization, key data points can be printed for record-keeping and saved to a USB drive for future reference.
The cooker lid is locked and opened by moving a pivot pin laterally using the handle at the front of the device. A pneumatic spring support makes opening the lid extremely effortless and safe.
The cooker uses a preset program to discharge cold air from the chamber, ensuring a pure steam sterilization environment. Internal steam circulation, controlled by a microcomputer, ensures balanced internal sterilization and temperature control.
When the temperature inside the cooker drops to the designated level after sterilization, the device automatically sprays water and automatically drains it.
• Turn on the back pressure air compressor and set the output pressure as required. The system will automatically intake air. Once the set temperature is reached, the program will automatically stop supplying air.
• Multiple safety features effectively prevent injury or damage to operators and equipment.