Single-point load cell HL6D
tension/compressionanalogweighing

single-point load cell
single-point load cell
Add to favorites
Compare this product
 

Characteristics

Type
tension/compression
Form
single-point
Output signal
analog
Applications
weighing
Other characteristics
precision
Rated load

10 kg, 20 kg, 30 kg, 50 kg
(22.05 lb, 44.09 lb, 66.14 lb, 110.23 lb)

Description

Precision - C3 Maximum Division - Nmax - 3000 Minimum Division - Vmin - Emax/7000 Composition Error - (%FS) ≤±0.020 Creep Deformation - (%FS/30min) ≤±0.0167 The influence of temperature on the output sensitivity - (%FS/10℃) - ≤±0.0175 The influence of temperature on the zero output - (%FS/10℃) - ≤±0.020 Rated Output - (MV/V) - 2.0±0.2 Input impedance - (Ω) - 409±6/1065±15 Output impedance - (Ω) - 350+3/1000+10 Insulation Resistance - (MΩ) - ≥5000(50VDC) Zero output - (%FS) - 2 Temperature compensation range - (℃) - -10~+40 Working temperature range - (℃) - -35~+65 Recommend excitation voltage - (V) - 5~12(DC) Maximum excitation voltage - (V) - 18(DC) Safety overload range - (%FS) - 150