Product OverviewThe CS-1065C-5H is a needle-style hydrophone designed for underwater acoustic detection, measurement, and monitoring. Its compact sensing head and slim probe make it suitable for installations requiring localized, high-frequency acoustic sensing in marine and underwater test environments.
Key Features- Needle-style hydrophone for underwater acoustic detection
- Compact sensing head with slim probe structure
- Measured sensitivity data across 100 kHz to 2000 kHz
- Suitable for underwater acoustic measurement and monitoring systems
- Cable-connected design for straightforward system integration
- Standard appearance and operating status
Technical Specifications- Model: CS-1065C-5H
- Product Type: Needle-Style Hydrophone
- Application: Underwater Acoustic Detection
- Head Diameter: Ø6.50 mm
- Rod Diameter: Ø1.27 mm
- Overall Length: 108 mm
- Needle Section Length: 80 mm
- Sensitivity Unit: μV/Pa
- Measured Frequency Points: 100 kHz, 200 kHz, 400 kHz, 700 kHz, 1000 kHz, 2000 kHz
Sensitivity Data- 100 kHz — 0.263 μV/Pa
- 200 kHz — 0.207 μV/Pa
- 400 kHz — 0.344 μV/Pa
- 700 kHz — 0.434 μV/Pa
- 1000 kHz — 0.496 μV/Pa
- 2000 kHz — 0.280 μV/Pa
- Measurement uncertainty: U = 29% (k = 2) for 100–700 kHz; U = 36% (k = 2) for 1000–2000 kHz
Structure and Dimensions- Head Diameter: Ø6.50 mm
- Rod Diameter: Ø1.27 mm
- Overall Length: 108 mm
- Needle Section Length: 80 mm
Applications- Underwater acoustic detection
- Acoustic signal measurement
- Hydrophone-based monitoring systems
- Laboratory acoustic testing
- Compact underwater sensing systems
FAQ (selected)What is the CS-1065C-5H used for? | The CS-1065C-5H is used for underwater acoustic detection, measurement, and monitoring applications.
What frequency points are available for sensitivity data? | Measured sensitivity values are available at 100 kHz, 200 kHz, 400 kHz, 700 kHz, 1000 kHz, and 2000 kHz.
What are the main dimensions? | Head diameter Ø6.50 mm, rod diameter Ø1.27 mm, overall length 108 mm, needle section length 80 mm.
Characteristics / Technical Specifications- Model: CS-1065C-5H
- Type: Needle-Style Hydrophone
- Application: Underwater Acoustic Detection and Measurement
- Head Diameter: Ø6.50 mm
- Rod Diameter: Ø1.27 mm
- Overall Length: 108 mm
- Needle Section Length: 80 mm
- Sensitivity Unit: μV/Pa
- Measured Frequency Points: 100 kHz, 200 kHz, 400 kHz, 700 kHz, 1000 kHz, 2000 kHz
- Sensitivity Values: 100 kHz=0.263 μV/Pa; 200 kHz=0.207 μV/Pa; 400 kHz=0.344 μV/Pa; 700 kHz=0.434 μV/Pa; 1000 kHz=0.496 μV/Pa; 2000 kHz=0.280 μV/Pa
- Measurement uncertainty: U = 29% (k = 2) for 100–700 kHz; U = 36% (k = 2) for 1000–2000 kHz
- Design: Compact needle-style with slim probe and cable-connected integration