Leak detection hydrophone sensor HP-01-050S
monitoringcommunicationfor pipes

Leak detection hydrophone sensor - HP-01-050S - Hurricane PZT - monitoring / communication / for pipes
Leak detection hydrophone sensor - HP-01-050S - Hurricane PZT - monitoring / communication / for pipes
Add to favorites
Compare this product

Characteristics

Applications
for pipes, communication, for leak detection, monitoring
Technology
MEMS
Polar pattern
omnidirectional
Other characteristics
compact, small-size, underwater, with built-in preamplifier

Description

Product Overview HP-01-050S is a micro hydrophone based on a semiconductor MEMS manufacturing platform. It features a compact and lightweight structure with a wide bandwidth of 1 kHz to 50 kHz, high sensitivity of -185 ±3.0 dB re 1V/µPa, and a built-in 40 dB amplifier. The small package size improves installation convenience and supports deployment in limited spaces, including array configurations where compact dimensions are important.

Key Features
  • Wide bandwidth: 1 to 50 kHz
  • High sensitivity: -185 ±3.0 dB re 1V/µPa
  • Built-in amplifier gain: 40 dB
  • High linearity with nonlinearity below 1%
  • Compact package size: Φ15 × 32 mm
  • Light weight: approximately 6 g (excluding cable weight)
  • Omnidirectional directivity


Stable Frequency Response The HP-01-050S offers strong frequency response consistency. Within the 1 kHz to 50 kHz bandwidth, sensitivity variation is less than ±3 dB. Sensitivity difference between units is also less than ±3 dB.

Compact MEMS Design This micro hydrophone uses MEMS technology to achieve a small form factor suitable for easier transport and installation and for dense array arrangements in limited spaces.

Temperature and Depth Performance Temperature influence on sensitivity is less than 0.1%/°C across the operating temperature range of -40 to 80°C. The hydrophone is insensitive to static water pressure, with sensitivity change less than ±1 dB from 0 to 100 m water depth.

Applications
  • Pipeline leak detection
  • Waterway monitoring
  • Underwater communication
  • Geological exploration
  • Marine fishery
  • Ultrasonic detection


Pin Configuration The HP-01-050S uses a 3-wire connection:
  • Pin 1 (Yellow): AC signal output
  • Pin 2 (Red): DC power supply
  • Pin 3 (Black): Ground


Dimensions and Weight
  • Package dimensions: Φ15 mm × 32 mm
  • Weight: approximately 6 g (cable weight not included)


Technical Specifications
  • Model: HP-01-050S
  • Product type: Micro hydrophone
  • Bandwidth: 1 to 50 kHz
  • Dynamic range: ±1000 Pa
  • Sound sensitivity: -185 ±3.0 dB re 1V/µPa
  • Temperature influence on sensitivity: <0.1%/°C
  • Nonlinearity: <1%
  • Noise resolution at 1 kHz: ~60 dB re µPa/√Hz
  • Built-in amplifier gain: 40 dB
  • Output amplitude: 1 Vppk
  • Current: 4 mA
  • Insulation resistance: >50 GΩ
  • Directivity: Omnidirectional
  • Supply voltage range: 5V to 15V
  • Absolute maximum supply voltage: 16V
  • Measurement condition: 25°C, 8V supply
  • Operating temperature range: -40 to 80°C
  • Storage temperature: -50 to 80°C
  • Operating depth: <100 m
  • Survival depth: 400 m
  • Pin configuration: 3-wire (Pin1 Yellow AC output, Pin2 Red V+, Pin3 Black GND)
  • Package dimensions: Φ15 mm × 32 mm
  • Weight: approximately 6 g (excluding cable)
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.