Monochromatic pyrometer CellaCombustion PX 17
with LED display°C°F

Monochromatic pyrometer - CellaCombustion PX 17 - Keller Pyrometer Systems - with LED display / °C / °F
Monochromatic pyrometer - CellaCombustion PX 17 - Keller Pyrometer Systems - with LED display / °C / °F
Monochromatic pyrometer - CellaCombustion PX 17 - Keller Pyrometer Systems - with LED display / °C / °F - image - 2
Add to favorites
Compare this product

Characteristics

Technology
monochromatic
Display
with LED display
Units of measurement
°C, °F
Communication
analog output, IO-Link
Configuration
stationary
Applications
industrial, for flue gas
Other characteristics
stainless steel, precision, optical
Temperature

Max.: 2,000 °C
(3,632 °F)

Min.: 400 °C
(752 °F)

Response time

100 ms

Description

Product description
The CellaCombustion PX 17 performs temperature measurement at a specific CO2-sensitive wavelength where hot carbonaceous gases exhibit high optical density and reliable radiative behaviour. It is designed for flue gas temperature measurement in gas-fired boilers, small combustion systems and similar industrial combustion processes.

Special features
  • Measuring range 400 to 2,000 °C
  • IO-Link interface for configuration and data exchange
  • Focusable optics for precise adjustment of measuring distance
  • Broadband anti-reflective precision lens (standard PZ 15.03)
  • 4-digit red LED display readable from a distance
  • Test current output for diagnostic purposes
  • 1 analogue output (0/4–20 mA) and 2 switching outputs (Open Collector)
  • Source (emissivity/transmittance) freely configurable


Technical data — Measurement parameters
Measuring range: 400 - 2000 °C
Sensor: Thermopile (single-colour)
Spectral range: CO2 band
Response time t98: ≤ 100 ms
Measurement uncertainty: 0.75 % of temperature reading [°C] + 1 K
Repeatability: 2 K
Temperature coefficient: 0.04 %/K
Resolution current output: 0.2 K + 0.03 % of selected range
Resolution interface: 0.1 K
Resolution display: 1 K

Optical variants
Standard lens: PZ 15.03 — focusing 0.8 m - ∞, distance ratio 75 : 1

Electrical parameters
Analog output: 0(4) - 20 mA linear, switchable, scalable
Load resistance: ≤ 500 Ω
Switching outputs: 2 × Open Collector 24 V DC, ≤ 150 mA
Interface: IO-Link
Power supply: 24 V DC +10 % / -20 %
Current consumption: ≤ 175 mA (24 V DC)

Camera
Video output (models with camera): Composite PAL, 1 Vpp, 75 Ω

Features
Sighting options: Through-the-lens sighting / Laser pilot light / Camera (depending on model)
Display: 4-digit red LED, digit height 8 mm
Status display: 4 × LED
Control elements: 3 buttons

General parameters
Connection: M12 screw connection, 5-pin
Ambient temperature: 0 - 65 °C
Storage temperature: -20 - +80 °C
Permissible humidity: 95 % r.H. max. (non-condensing)
Dimensions: Ø 65 mm × 220 mm (max. 277 mm)
Housing: Stainless steel V2A (1.4305)
Protection class: IP 65 (DIN 40050)
Weight: approx. 0.9 kg

Adjustable parameters
Analog output scaling (0/4–20 mA); smoothing filter; memory operation mode and hold time; emissivity; transmittance; alarm limits and operating mode; ATD function parameters; current and temperature simulation; temperature unit °C/°F. Camera models: TBC, white balance, measuring point number.

Functions
Overtemperature signal (internal temperature > 75 °C); Service function (simulation of measured value or current signal); ATD (Automatic Temperature Detection) for discontinuous processes.

Scope of delivery
Pyrometer CellaTemp PX; Connection cable VK 02/L AF 1 (5 m); Video cable VK 02/F (5 m) for camera models; Short manual.

Measuring field (examples)
Measuring distance / Measuring field diameter (examples):
0.00 mm → 24.00 mm
32.00 mm → 23.47 mm
64.00 mm → 22.93 mm
96.00 mm → 22.40 mm
128.00 mm → 21.87 mm
160.00 mm → 21.33 mm
192.00 mm → 20.80 mm
224.00 mm → 20.27 mm
256.00 mm → 19.73 mm
288.00 mm → 19.20 mm
320.00 mm → 18.67 mm
352.00 mm → 18.13 mm
384.00 mm → 17.60 mm
416.00 mm → 17.07 mm
448.00 mm → 16.53 mm
480.00 mm → 16.00 mm
512.00 mm → 15.47 mm
544.00 mm → 14.93 mm
576.00 mm → 14.40 mm
608.00 mm → 13.87 mm
640.00 mm → 13.33 mm
672.00 mm → 12.80 mm
704.00 mm → 12.27 mm
736.00 mm → 11.73 mm
768.00 mm → 11.20 mm
800.00 mm → 10.67 mm

Characteristics / technical specifications
  • Model: CellaCombustion PX 17
  • Measuring range: 400 – 2,000 °C
  • Optics (standard): PZ 15.03, focus 0.8 m – ∞, distance ratio 75 : 1
  • Sensor / principle: Thermopile / one-colour
  • Interface: IO-Link (configurable)
  • Analog output: 0(4) – 20 mA; 2 switching outputs (Open Collector 24 V DC)
  • Response time: ≤ 100 ms
  • Uncertainty: 0.75 % of reading + 1 K; repeatability 2 K
  • Display: 4-digit red LED; status 4 × LED; 3 control buttons
  • Power supply: 24 V DC (+10 % / -20 %)
  • Protection class: IP 65; Housing: stainless steel V2A
  • Dimensions: Ø 65 mm × 220 mm (max. 277 mm); Weight: ~0.9 kg
  • Video (model with camera): Composite PAL

Exhibitions

Meet this supplier at the following exhibition(s):

Shenzhen International Semiconductor & IC Exhibition
Shenzhen International Semiconductor & IC Exhibition

9-11 Sep 2026 Shenzhen (China)

Inter Foundry 2026
Inter Foundry 2026

10-12 Sep 2026 Coimbatore (India)

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.