Pyrometer with LED display CellaTemp® PX 40
°C°F4-20 mA

Pyrometer with LED display - CellaTemp® PX 40 - Keller Pyrometer Systems - °C / °F / 4-20 mA
Pyrometer with LED display - CellaTemp® PX 40 - Keller Pyrometer Systems - °C / °F / 4-20 mA
Pyrometer with LED display - CellaTemp® PX 40 - Keller Pyrometer Systems - °C / °F / 4-20 mA - image - 2
Add to favorites
Compare this product

Characteristics

Display
with LED display
Units of measurement
°C, °F
Communication
4-20 mA, analog output, IO-Link
Protection level
IP65
Configuration
fixed
Applications
industrial
Other characteristics
stainless steel, precision, optical
Temperature

Min.: 500 °C
(932 °F)

Max.: 3,000 °C
(5,432 °F)

Spectral range

0.95 µm, 1.05 µm

Response time

10 ms, 20 ms

Description

Product description:
The CellaTemp® PX 40 is a digital two-colour pyrometer for measuring temperatures from 500 to 3,000 °C. The two-colour (quotient) measuring method reduces sensitivity to disturbances such as dust and steam in the field of view, soiled protective windows or varying surface conditions compared with single-colour pyrometers. For precise targeting of the measurement object, the instrument can be equipped with through-the-lens sighting, a laser pilot light or a video camera module.

Special features:
  • Measuring range: 500 to 3,000 °C
  • IO-Link interface
  • Focusable interchangeable lenses for adapting measuring distance
  • Broadband anti-reflective precision optics
  • High-visibility LED display
  • All parameters adjustable via built-in keypad
  • Test current output for diagnostics
  • 1 analog output and 2 switching outputs
  • Configurable source / measurement channel
  • ATD function for automatic temperature detection
  • SCM contamination monitoring


Additional product information:
Available targeting options: through-the-lens sighting, laser pilot light, video camera module. Focusable lens system with multiple objectives and close-up/macro lenses for short measuring distances. Camera option provides composite PAL video output for alignment and observation.

Technical specifications:
  • Measuring principle: two-colour (quotient)
  • Measuring range: 500 - 3000 °C (in segments)
  • Sensor: dual photodiode
  • Spectral range: 0.95 / 1.05 µm
  • Response time t98: varies by range (examples: 500–1400 °C ≤ 10 ms (T > 650 °C); 650–1700 °C ≤ 20 ms (T > 650 °C) / ≤ 10 ms (T > 750 °C); 750–2400 °C ≤ 10 ms (T > 950 °C); 850–3000 °C ≤ 10 ms (T > 1050 °C))
  • Measurement uncertainty: 1 % of reading [°C]
  • Repeatability: 2 K
  • Temperature coefficient: 0.05 %/K
  • Resolution current output: 0.2 K + 0.03 % of selected range
  • Resolution interface: 0.1 K
  • Resolution display: 1 K
  • Analog output: 0(4)–20 mA, linear, switchable, scalable
  • Load for analog output: ≤ 500 Ω
  • Switching outputs: 2 × open collector 24 V DC, ≤ 150 mA
  • Interface: IO-Link
  • Power supply: 24 V DC +10 % / -20 %
  • Current consumption: ≤ 175 mA (24 V DC)
  • Video output (camera model): Composite PAL, 1 Vpp, 75 Ω
  • Display: 4-digit red LED (digit height 8 mm)
  • Status display: 4 × LED
  • Controls: 3 buttons (keyboard-adjustable parameters)
  • Dimensions: Ø 65 mm × 220 mm (max. 277 mm)
  • Housing: Stainless steel V2A (1.4305)
  • Protection class: IP65 (according to DIN 40050)
  • Weight: approx. 0.9 kg
  • Connection: M12 thread, 5-pin
  • Ambient temperature (operation): 0 - 65 °C
  • Storage temperature: -20 - +80 °C
  • Permissible humidity: max. 95 % r.H. (non-condensing)
  • Scope of delivery (example): Pyrometer CellaTemp PX, connection cable VK 02/L AF 1 (5 m), video cable VK 02/F (5 m) for camera models, brief manual
  • Adjustable parameters (selection): analog output scaling, smoothing filter, memory/hold mode, emissivity, transmittance, alarm limits and modes, ATD parameters, simulation of current and temperature, unit °C/°F, measurement channel selection (two-colour / single-colour)
  • Functions (selection): overtemperature alarm, service simulation, ATD for discontinuous processes, contamination monitoring (SCM)
  • Optical variants / lenses (selection): macro lens PA 40.01 (focus 0.086 - 0.115 m) for highest temperature ranges; standard objective PZ 20.01 (0.4 m - ∞); close-up PZ 20.03 (0.2 - 0.4 m); wide-angle PZ 20.05 (0.2 m - ∞); telephoto PZ 20.06 (1.2 m - ∞); telephoto PA 20.06 (0.6 m - ∞) — lens choice depends on AF version / measuring range

Catalogs

No catalogs are available for this product.

See all of Keller Pyrometer Systems‘s catalogs

Exhibitions

Meet this supplier at the following exhibition(s):

Shenzhen International Semiconductor & IC Exhibition
Shenzhen International Semiconductor & IC Exhibition

9-11 Sep 2026 Shenzhen (China)

Inter Foundry 2026
Inter Foundry 2026

10-12 Sep 2026 Coimbatore (India)

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.