video corpo

Laboratory sterilizer ETO
ethylene oxideautomaticfor syringes

laboratory sterilizer
laboratory sterilizer
laboratory sterilizer
laboratory sterilizer
laboratory sterilizer
Add to favorites
Compare this product
 

Characteristics

Laboratory/process
laboratory
Sterilization method
ethylene oxide
Other characteristics
automatic
Applications
for syringes, for the pharmaceutical industry
Temperature range

Min.: 20 °C
(68 °F)

Max.: 50 °C
(122 °F)

Description

The ETO sterilisers have been designed to sterilise – by means of ethylene oxide – heat-sensitive materials, such as plastic syringes, infusion sets, dialysis filter cartridges, plastic materials and special surgical tools. “Standard” and custom programmes for every need. he equipment process is developed by our Automation Department, according to the current codes/standards and the type of product being processed. Vacuum breaker or pressure leak tests; load conditioning programme; vacuum sterilisation programme; product degassing programme; and a gas neutralising programme, etc. The ETO gas is injected at a temperature of 60°C into the chamber via a PID-controlled modulating valve and the condensate is continuously evacuated through the drain, in order to ensure excellent heat distribution during the entire sterilisation phase (temperature deviation below ± 1°C). • Double-walled square chamber, made entirely from 316L or 316Ti stainless steel. • Ashlar-type total cavity comprising 304 or 316L/316Ti stainless steel. • Piping made entirely from 316L stainless steel with sanitary • fittings (tri-clamp ferrules and hygienic flanges). • Any surfaces that come into contact with the product and process fluids are mechanically polished to a roughness level of less than 0.35 micron. • Automatic horizontal sliding chamber doors. • Pneumatically pressurised chamber door sealing gasket (cwith process air). • 316L/316Ti stainless steel components and tools, in addition to elastomers manufactured in compliance with FDA 21 CFR, Part 177. • The chamber, heads, pipes, components and instruments are properly insulated by a cutting-edge material. • Built-in steam generator.

Exhibitions

Meet this supplier at the following exhibition(s):

ACHEMA 2024
ACHEMA 2024

10-14 Jun 2024 Frankfurt am Main (Germany) Hall 4.1 - Stand A7

  • More information
    *Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.