The continuous fully-glazed partition Lindner Life Fire with fire protection requirement, provide an open and transparent feeling in the room. This is complemented by a warm natural material, such as profiles made of wood.
The system ist studless and the glass is buttjointed. The system construction allows it to be installed directly on site, which grants a flexible adaptation to the spatial conditions.The installation-friendly system design provide for a quick assembly and for a complete dismantling as well.
open and transparent feeling of space
frameless and stud-free fully-glazed construction with fire protection
profiles made from wood
Technical data
Design option
Simple glazing
Connecting Profiles
Made of veneered multilayer panels or solid wood and solid wood glazing beads
Guidelines
Lindner visual assessment criteria for glazing systems
Tolerances
Ceiling deformation in a range of up to 25 mm
Glass pane structure
Mono or insulated construction
Single or laminated safety glass
Standard: black edge seal
Transparent fire protection gel filling
Joint sealing
sealing tapes and silicone joints
Glass with vertical 15mm edge printing in black
Connection
invisible or visible connections by using multi-part wooden profiles possible
Weight
50 - 100 kg/m²
Dimensions
Height
Standard up to 3.500 mm depending on glass thickness
Joint width
< 6 mm
Axis grid
1500 mm
Wall thickness
100 mm
125 mm
150 mm
Glass thickness
27 – 67 mm
ceiling profile
80 mm
Floor and wall connection profile
54 mm
Visible width of edge seal
approx. 15 mm
Hint dimensions
The maximum wall height and the maximum module width can differ depending on the building physics!