OverviewThe ZENITH platform (models 20X and 30X) is a modular ozone generation system engineered for industrial water and odor control projects with high ozone demand and challenging operating conditions. Modular capacity, integrated cooling and configurable controls enable planning for high-capacity generation within site and process constraints. Final model selection should consider flow, ozone demand, feed gas source, cooling and site requirements.
Benefits- Reduced energy consumption — optimized electrical use to lower operating cost.
- Reliable continuous operation — designed for stable ozone production under demanding conditions.
- Simplified monitoring and control — PLC and HMI with remote access options for easier operation and diagnostics.
Applications- Municipal wastewater treatment
- Industrial water treatment and process water purification
- Odor control in industrial facilities
- Aquaculture water quality management
- Water parks and recreational facilities
- Cooling tower water treatment
NotesDesigned for high ozone output with configurable operating range. System configuration must account for feed gas source (LOX/PSA), oxygen quality and flow, cooling type (chilled/glycol), electrical service and site clearances. Choose between ZENITH 20X and 30X based on required ozone mass output and available utilities.
Technical specifications- ZENITH 20X
- Enclosure: Sealed NEMA 12 with integral cooler. Optional NEMA 4X with integral cooler.
- Minimum clearance: Front/Back/Right 36 in (915 mm) / Left 18 in (457.5 mm).
- Dimensions (L x D x H): 111 in (2,820 mm) x 35 in (889 mm) x 94 in (2,388 mm).
- Weight: 3,500 lbs (1,588 kg).
- Facility connections: Oxygen inlet: 3/4 in tube; Ozone outlet: 3/4 in tube; Cooling water supply/return: 1-1/4 in 316L SS, NPT; Electrical service: 230 VAC / 3ph / 50-60 Hz / 200 A (156 FLA); Compressed air feed: 1/4 in push-lock fitting.
- Ozone output: LOX: up to 182.4 kg/d @ 10% concentration, 204 kg/d @ 8% concentration. PSA: up to 153.6 kg/d @ 10% concentration, 180 kg/d @ 8% concentration. Outlet pressure: 20 psig (optional up to 25 psig).
- Oxygen requirements: PSA, VSA, VPSA or LOX acceptable. Max oxygen flow: 1,860 slpm @ 20 psi inlet. Gasified LOX feed: dew point < -65°C, total hydrocarbons (as CH4) < 15 ppm. PSA feed: O2 concentration ≥ 93%. Max 0.1 µm inlet filter recommended (not included). N2 feed not required.
- Cooling water: Closed-loop chilled water. Fluid: food-grade glycol-water blend (30/70, not included). Typical cooling water flow: ~40 gpm. Cooling load: ~19.7 Ton.
- Controls & communication: Schneider Electric Modicon M251 PLC; 15 in RedLion color touch HMI; remote access via Ethernet/IP and webserver (Ethernet switch provided). Optional cellular modem. UPS provisioned.
- Control routines: Fixed or variable O3 % by weight. Automatic: PID ORP (mV) or PID DO3 (ppm). Manual: fixed output (ppd or kg/h) or full manual.
- Accessories & instrumentation: 75 kVA step-down transformer (shipped separately, install by others); enclosure ambient O3 analyzer; enclosure ambient temperature transmitter; O2 inlet mass flowmeter and manual rotameter; O2 inlet temperature and pressure transmitters; O3 outlet pressure transmitter; high concentration O3 analyzer; inlet/outlet cooling water temperature instruments.
- Compliance: UL 508A Listed, CSA, CE.
- ZENITH 30X
- Enclosure: Sealed NEMA 12 with integral cooler. Optional NEMA 4X with integral cooler.
- Minimum clearance: Front/Back/Right 36 in (915 mm) / Left 18 in (457.5 mm).
- Dimensions (L x D x H): 111 in (2,820 mm) x 35 in (889 mm) x 94 in (2,388 mm).
- Weight: 4,600 lbs (2,090 kg).
- Facility connections: Oxygen inlet: 1-1/4 in 316 SS, NPT; Ozone outlet: 1-1/4 in 316 SS, NPT; Cooling water supply/return: 1-1/4 in 316L SS, NPT; Electrical service: 230 VAC / 3PH / 60 Hz / 300 A (234 FLA); Compressed air feed: 1/4 in push-lock fitting.
- Ozone output: LOX: up to 273.6 kg/d @ 10% concentration, 306 kg/d @ 8% concentration. PSA: up to 230.4 kg/d @ 10% concentration, 270 kg/d @ 8% concentration. Outlet pressure: 20 psig (optional up to 25 psig).
- Oxygen requirements: PSA, VSA, VPSA or LOX acceptable. Max oxygen flow: 2,790 slpm @ 20 psi inlet. Gasified LOX feed: dew point < -65°C, total hydrocarbons (as CH4) < 15 ppm. PSA feed: O2 concentration ≥ 93%. Max 0.1 µm inlet filter recommended (not included). N2 feed not required.
- Cooling water: Closed-loop chilled water. Fluid: food-grade glycol-water blend (30/70, not included). Typical cooling water flow: ~55 gpm. Cooling load: ~25.0 Ton.
- Controls & communication: Schneider Electric Modicon M251 PLC; 15 in RedLion color touch HMI; remote access via Ethernet/IP and webserver (Ethernet switch provided). Optional cellular modem. UPS provisioned.
- Control routines: Fixed or variable O3 % by weight. Automatic: PID ORP (mV) or PID DO3 (ppm). Manual: fixed output (ppd or kg/h) or full manual.
- Accessories & instrumentation: 112 kVA step-down transformer (shipped separately, install by others); enclosure ambient O3 analyzer; enclosure ambient temperature transmitter; O2 inlet mass flowmeter and manual rotameter; O2 inlet temperature and pressure transmitters; O3 outlet pressure transmitter; high concentration O3 analyzer; inlet/outlet cooling water temperature instruments.
- Compliance: UL 508A Listed, CSA, CE.