1/2" disc thermostats with quick make/quick break switching action will automatically reset at preset temperature. Available with normally closed (open on temperature rise) or normally open (close on temperature rise) contact configurations.
General
________________________________________
Models KO & KS
Available with nominal calibration temperature range of -20º C to 195º C. Others upon request.
Models CO & CS
Available with nominal calibration temperature range of -5º C to 200º C. Others upon request.
Standard Differential
The standard temperature differential between the opening and closing temperature is up to 40º C. Tighter differentials available upon request.
Contact Ratings
________________________________________
Models KO & KS
UL:
15 amps 120 VAC resistive
10 amps 240 VAC resistive
VDE:
10 amps 250 VAC 100,000 cycles
16 amps 250 VAC 10,000 cycles
Models CO & CS
VDE:
16 amps 250 VAC, 10,00 cycles