Digital camera TN463
for research and developmentfor scientific applicationsindustrial

Digital camera - TN463 - Raythink | Raytron Industrial - for research and development / for scientific applications / industrial
Digital camera - TN463 - Raythink | Raytron Industrial - for research and development / for scientific applications / industrial
Add to favorites
Compare this product

Characteristics

Technology
digital
Applications
industrial, for scientific applications, for research and development
Function
inspection, monitoring, thermal imaging, measuring
Spectrum
infrared, IR
Sensor
microbolometer, FPA, VOx
Interface
GigE, gigabit Ethernet, PoE, USB 3.0, IP, ONVIF
Resolution level
640 x 512
Other characteristics
fixed-focus, with measurement software, fixed, uncooled

Description

Overview
The TN463 fixed-mount thermal camera is built for high-speed online temperature measurement and reliable system integration. It integrates a 640 × 512 uncooled VOx detector with a 12 μm pixel pitch and supports up to 60 Hz full-frame output. Two selectable temperature ranges (-20°C to 150°C and 100°C to 650°C) with accuracy ±2°C or ±2% enable precise monitoring in industrial and research applications.

Key features
  • High-resolution, high-frame-rate imaging: 640 × 512 uncooled VOx detector, 12 μm pixel pitch, up to 60 Hz output.
  • Accurate temperature measurement: dual ranges (-20°C–150°C; 100°C–650°C), accuracy ±2°C or ±2% (whichever greater), support for reflected temperature, ambient temperature, humidity, emissivity and distance correction.
  • Advanced measurement & analysis: up to 20 measurement objects (point/line/area), isotherm configuration, historical temperature curves, offline analysis, report export via professional software (36 tools).
  • Industrial connectivity: RJ45 Gigabit Ethernet, USB 3.0 UVC, RS-485 (software/hardware trigger, Pelco-D/P), PoE power; GigE for high-speed transmission.
  • Protocol support & integration: ONVIF, MQTT, Modbus TCP/RTU; network stack includes IPv4, HTTP/HTTPS, SMTP, FTP, RTSP/RTP, TCP/UDP and related protocols for secondary development.
  • Alarm & triggering: I/O hardware triggering, temperature and abnormality alarms, alarm output, audio alarm, synchronized video recording and image capture.
  • Multiple lens options: 6.9 mm, 9.1 mm, 19 mm and 25 mm for flexible field-of-view configurations.

Thermal Imaging Parameters
Detector Type: Uncooled VOx infrared detector
Resolution: 640 × 512
Pixel Pitch: 12 μm
Frame Rate: 60 Hz (adjustable)
Spectral Band: 7.5–14 μm
NETD: ≤ 40 mK (@25°C; F#1.0, 25 Hz)
Focal Length options: 6.9 mm, 9.1 mm, 19 mm, 25 mm
Focus Mode: Fixed focus, athermalized
FOV options: 62.8°×50.2°, 48°×38.4°, 22.9°×18.4°, 17.4°×14°

Image Adjustment
  • 20 palettes (including black-hot, white-hot, rainbow)
  • Digital zoom 1.0–8.0×
  • Image mirroring: horizontal / vertical / diagonal

Temperature Measurement
Ranges: -20°C–150°C and 100°C–650°C
Accuracy: ±2°C or ±2% of reading (whichever is greater)
Corrections: reflected temperature, ambient temperature, humidity, emissivity, distance
Measurement tools: point, line, area; up to 20 measurement objects; isotherm support
Alarms & capture: thermal image capture, video recording, alarm output, audio alarm, offline analysis and report generation

System Interface
Communication: RJ45 Gigabit Ethernet; USB 3.0 UVC; RS-485 (software/hardware trigger, Pelco-D/P); PoE supported
Video codecs: H.264, H.265
Audio: 1 Line In, 1 Line Out
Alarm I/O: 1 input, 1 output
Storage: SD card expansion port reserved
Network protocols: IPv4, HTTP, HTTPS, SMTP, FTP, UPnP, DNS, DDNS, NTP, RTCP, RTSP, RTP, TCP, UDP, IGMP, ICMP, DHCP, GigE
Interface protocols: Modbus TCP/RTU, ONVIF, MQTT

General Specifications
Operating temperature: imaging -40°C to +60°C; measurement -20°C to +60°C
Humidity: <95% RH
Power: 12 V DC or PoE
Typical consumption: <4.5 W
Dimensions: approx. 89.7–94.9 × 49 × 49 mm (varies by lens)
Weight: ~290 ± 5 g

Application scenarios
  • Industrial automation
  • Equipment condition monitoring
  • Wide-area scenario monitoring
  • Scientific research and testing

Technical specifications
  • Model: TN463
  • Detector: uncooled VOx, 12 μm pixel pitch
  • Resolution: 640 × 512
  • Frame rate: up to 60 Hz
  • Spectral band: 7.5–14 μm
  • NETD: ≤ 40 mK (@25°C; F#1.0, 25 Hz)
  • Focal lengths: 6.9 mm / 9.1 mm / 19 mm / 25 mm
  • Measurement ranges: -20°C–150°C; 100°C–650°C
  • Accuracy: ±2°C or ±2% of reading
  • Interfaces: RJ45 Gigabit Ethernet, USB 3.0 UVC, RS-485, PoE
  • Protocols: ONVIF, MQTT, Modbus TCP/RTU; full network support
  • Power: 12 V DC or PoE; consumption <4.5 W
  • Operating temp: imaging -40°C to +60°C; measurement -20°C to +60°C

Catalogs

No catalogs are available for this product.

See all of Raythink | Raytron Industrial‘s catalogs

Exhibitions

Meet this supplier at the following exhibition(s):

SPS 2026
SPS 2026

24-26 Nov 2026 Nuremberg (Germany) Hall 7A - Stand 623

  • More information
    International Power Expo
    International Power Expo

    3-05 Dec 2026 Shanghai (China)

  • More information
    *Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.
    About DirectIndustry
    DirectIndustry is a marketplace that offers B2B players a complete experience, from product sourcing to purchase. DirectIndustry is an entity of VirtualExpo Group.