• Products
  • Catalogs
  • News & Trends
  • Exhibitions

Plate filter unit Version 12/9
panelairhigh-throughput

Plate filter unit - Version 12/9 - Realien GmbH - panel / air / high-throughput
Plate filter unit - Version 12/9 - Realien GmbH - panel / air / high-throughput
Add to favorites
Compare this product

Characteristics

Technology
panel, plate
Designed for
air
Other characteristics
high-throughput, compact
Flow

Max.: 4,590 m³/h
(162,094.32 ft³/h)

Min.: 3,360 m³/h
(118,657.28 ft³/h)

Description

Product description
The Fan Filter Unit is a classic solution for cleanroom applications. Air is drawn in by a powerful fan and discharged after a multi-stage filtration process. The unit can also generate a stable slight overpressure for cleanroom environments.

Device versions
  • Version 12/9: Standard version, dimensions 1198x898x615 mm.
  • Version 12/12: Large version, dimensions 1198x1198x615 mm.
  • Version LFK: Compact version, dimensions 1000x1000x300 mm.

Technical data — device data ~230 V
Columns: (empty) | Version 12/12 (1198x1198x615mm) | Version 12/9 (1198x898x615mm) | Version LFK (1000x1000x300mm)
Max. airflow | 4430 m³/h | 3540 m³/h | 3360 m³/h
Weight | 112 Kg | 89 Kg | 70 Kg
Max. discharge air velocity | 1.09 m/s (for 12/12 & 12/9 combined) | 1.09 m/s | 0.81 m/s
Rated voltage | 1~208 - 277 V, 50 / 60 Hz (all versions)
Rated speed | 1250 min-1 (all versions)
Nominal power | 460 W
Rated current | 2.40 - 1.70 A
Fan | RH45G-6IK.BD.2R, aluminium
Insulation | Sound-damping, fire class A1
Enclosure protection | IP44
Emission sound pressure level | < 63 dB(A) (12/12 & 12/9 combined), < 59 dB(A) (LFK)

Technical data — device data ~230/400 V
Columns: (empty) | Version 12/12 (1198x1198x615mm) | Version 12/9 (1198x898x615mm) | II 2G Ex h IIB T3 Gb / Version 12/9 (1198x898x615mm)
Max. airflow | 4590 m³/h | 3670 m³/h | 3670 m³/h
Weight | 117 Kg | 98 Kg | 104 Kg
Max. discharge air velocity | 1.2 m/s (all versions)
Rated voltage | 3~230/400 V, 50 Hz (mainly) | 3~230/400 V, 50 Hz | 3~400 V, 50 Hz (for Ex version)
Rated speed | 1380 min-1 (max., 12/12 & 12/9) | 1360 min-1 (LFK)
Nominal power | 710 W (12/12) | 430 W (12/9 LFK) | 430 W (LFK variants)
Rated current | 2.50 / 1.45 A (12/12 / 12/9) | 0.80 A (LFK variant)
Fan | RH45G-4DK.4I.2R, aluminium (12/12 & 12/9) | RH45M-4DK.4Y.1R (LFK variant)
Insulation | Sound-damping, fire class A2
Enclosure protection | IP44
Emission sound pressure level | < 65 dB(A) (depending on version)

Functional description
The FFU operates in recirculation mode. Air from the intake area (1) is drawn in by the fan (5). The prefilter (3) cleans the intake air. The final HEPA/ULPA filter (11) filters the air to cleanroom standards. The filter guard (6) prevents damage to the filter media. A perforated plate (14) is used to generate a displacement flow with low turbulence.

Download
Operating manual available (PDF).

Characteristics / Specifications
  • Model / series: FU1 (Fan Filter Unit, FFU).
  • Main purpose: Air cleaning in cleanroom applications, generation of overpressure and low-turbulence displacement flow.
  • Available versions: 12/9 (1198x898x615 mm), 12/12 (1198x1198x615 mm), LFK (1000x1000x300 mm).
  • Max. airflow (230 V): up to 4430 m³/h (12/12), 3540 m³/h (12/9), 3360 m³/h (LFK).
  • Max. airflow (230/400 V): up to 4590 m³/h (12/12), 3670 m³/h (12/9 / LFK variants).
  • Weight by version (varies with voltage): 70–117 Kg (depending on version and voltage variant).
  • Max. discharge / air velocity: approx. 0.81–1.2 m/s depending on version and voltage.
  • Rated voltage: Single-phase 1~208–277 V (230 V variants) or three-phase 3~230/400 V (230/400 V variants); specific Ex version with 3~400 V.
  • Rated speed: 1250 min-1 (230 V), up to 1380 / 1360 min-1 (230/400 V variants, max.).
  • Nominal power: 460 W (typ.), up to 710 W (stronger 3~ variants).
  • Rated current: approx. 1.45–2.50 A (depending on version and voltage).
  • Installed fan types: various RH series (aluminium construction, e.g. RH45G-6IK.BD.2R, RH45G-4DK.4I.2R, RH45M-4DK.4Y.1R).
  • Insulation: Sound-damping, fire class A1 or A2 (depending on variant).
  • Enclosure protection: IP44.
  • Emission sound pressure level: typically < 59–65 dB(A) depending on version.
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.
About DirectIndustry
DirectIndustry is a marketplace that offers B2B players a complete experience, from product sourcing to purchase. DirectIndustry is an entity of VirtualExpo Group.