Level measurement and 8 level outputs are possible using one tube.
Not influenced by adhering materials.
Available with gravity correction function which eliminates correction by actual fluid and EMPTY/SPAN adjustment function which is implemented through one-touch operation.
This instrument can be also used as a fluid volume meter and a pressure meter.
Level measurement using one tube
Inactive gas is supplied to the tube installed in the tank and level is measured using the back-pressure inside the tube that is generated according to the fluid level.
LE110 is a back-pressure type level meter based on LE100 with additional differential pressure (gauge pressure and atmospheric pressure) function. This instrument can be used in a tank where the pressure inside the tank changes.
The use of PFA tube enables measurement of corrosive chemicals.
Easy initial setting (Empty/Span adjustment)
The range set by the high and the low limits is displayed as 0-100%.
Can be used as a liquid volume and a pressure meter
The linearizer function enables level measurement of a vessel with a complicated shape.
This instrument can be also used as a pressure sensor with high repeatability (±0.3% of span).