video corpo

Indoor air quality volatile organic compound sensor RLQ-SD-U
VOCroom0-10 V

Indoor air quality volatile organic compound sensor - RLQ-SD-U - S+S Regeltechnik - VOC / room / 0-10 V
Indoor air quality volatile organic compound sensor - RLQ-SD-U - S+S Regeltechnik - VOC / room / 0-10 V
Indoor air quality volatile organic compound sensor - RLQ-SD-U - S+S Regeltechnik - VOC / room / 0-10 V - image - 2
Add to favorites
Compare this product

Characteristics

Gas type
VOC
Applications
for indoor air quality, room
Output
0-10 V
Protection class
IP30
Other characteristics
maintenance-free, with auto-calibration
Measuring range (%)

Min.: 0 %

Max.: 100 %

Description

Maintenance-free AERASGARD® RLQ - SD room air quality measuring transducer with active output, automatic calibration (fixed), in an elegant plastic housing with snap-on cover, for determining the air quality in three VOC sensitivity levels (low/medium/high). The transmitter converts the measured values into a standard signal of 0-10 V or 4...20 mA (switchable). Maintenance-free AERASGARD® RLQ - W room air quality measuring transducer with active/switching output, automatic calibration (can be deactivated), in an elegant plastic housing with snap-on cover, optional with traffic light indicator (five coloured LEDs), for determining the air quality in three VOC sensitivity levels (low/ medium/high). The transmitter converts the measured values into a standard signal of 0-10 V or 4...20 mA (switchable). The sensor devices are used in offices, hotels, convention centres, apartments, shops, etc. for the purpose of evaluating the indoor climate. This enables energy-saving room ventilation on an as-needed basis, thereby reducing operating costs and improving well-being. The air quality is detected by a VOC sensor (mixed gas sensor for volatile organic substances). This sensor determines the load of contaminated gases in the room air, such as from cigarette smoke, body perspiration, exhaled breathing air, solvent vapours, emissions from building components, etc. Low, medium or high VOC sensitivity can be selected depending on the expected air contamination.

Catalogs

No catalogs are available for this product.

See all of S+S Regeltechnik‘s catalogs
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.