Modular UPS CNM331 Series
on-lineparallelthree-phase

modular UPS
modular UPS
modular UPS
modular UPS
Add to favorites
Compare this product
 

Characteristics

Type
on-line, parallel
Electrical characteristics
three-phase, AC
Applications
data center, for telecom applications, for PC
Other characteristics
with LCD display, modular, redundant, with built-in battery, 19" rack
Power

Min.: 27,000 W

Max.: 270,000 W

Input voltage

380 V, 400 V, 415 V

Min.: 208 V

Max.: 478 V

Output voltage

380 V, 400 V, 415 V

Output power kVA

Min.: 30 kVA (40.79 hp)

Max.: 300 kVA (407.89 hp)

Description

The CNM331 series three phases input and three phases output UPS,adopted modular design and the N+X parallel redundant technology,the capacity from 20KVA to 300KVA. This series of UPS products can almost completely solve all the power problems such as power off, high voltage, low voltage, instantaneous voltage drop, reduce the oscillation, high voltage pulse, voltage fluctuations, surge voltage, harmonic distortion, clutter interference, frequency fluctuations etc. This product is suitable for a wide range of applications, for example: computer equipment, communication systems and automation equipment etc. Digital control • All parts of the series architecture using digital control,the performance indicators of UPS are very good and the control system more reliable. 19 inch standard cabinet can perfectly match the application environment of data center N+X parallel redundant of power module • The quantity of power module can set freely. When the power module more than 2 pieces use on parallel, the system availability reached 99.999%,the MTBF will be over 250,000 hours Control system parallel redundant • Each power module uses an independent control system,the power module of UPS is controlled independently based on the information shared by each other. Suppose any power module fails, it can be disconnected from the parallel system immediately. It will not cause harm to the complete system. Support to use on parallel, maximum 4 cabinets Optimized distribution bus cabinet to ensure the safety when use on parallel Separate bypass for each power module Common use battery bank when several UPS power modules or UPS cabinet use on parallel

Catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.