• High degree of protection IP 69, IP 69K
• Salt-mist proof
• Suitable for the food processing industry
• Thermoplastic enclosure
• Design to EN 50047
• Slow action
• Double insulated
• Applied standards - EN ISO 13849-1, EN 60947-5-1, EN ISO 14119
Enclosure - thermoplastic, glass-fibre reinforced, impact resistant, self-extinguishing UL 94 V-0
Cover - thermoset, glass-fibre reinforced, impact resistant, self-extinguishing UL 94 V-0
Switch type - type 1
Coding level - no coding
Degree of protection - IP 66, IP 67, IP 69 (IEC/EN 60529) / IP 69K (ISO 20653)
Contact material - silver
Switching system - slow action, positive break NC contacts ; positive break depends on the actuator used
Switching elements - 1 NC/1 NO contact, type Zb
Connection - screw connection terminals
Cable cross-section - max. 2.5 mm² (incl. conductor ferrules)
Cable entry - 1 x M20 x 1.5
Rated impulse withstand voltage Uimp - 4 kV
Rated insulation voltage Ui - 250 V
Conventional thermal current Ithe - 6 A
Rated operating current/voltage Ie/Ue - 6 A/250 VAC; 0,25 A/230 VDC;
4 A/24 VDC
min. 10 mA / 24 V
Utilisation category - AC-15; DC-13
Short-circuit protection - 6 A gG/gN fuse
Operation cycles - max. 1800/h
Ambient temperature - –20 °C … +70 °C