OverviewThermo Scientific Transcend TLX TurboFlow UHPLC systems combine online TurboFlow sample cleanup with multichannel UHPLC for streamlined LC‑MS workflows. These systems reduce manual sample preparation for complex matrices (plasma, urine, etc.), increase instrument utilization through staggered channel scheduling, and support higher throughput configurations up to four channels (TLX‑4). Aria MX software simplifies method setup, scheduling and control.
Highlights- Online automated sample cleanup: TurboFlow technology enables direct injection of complex matrices into LC‑MS, minimizing offline prep and saving analyst time.
- Multichannel throughput: TLX‑2 and TLX‑4 configurations run staggered analyses to keep the mass spectrometer active, increasing throughput two‑ to four‑fold without new methods.
- Expandable sample capacity: Add cool stacks or a Vanquish Charger Module to extend capacity from standard vial racks to multiple 96/384‑well plate formats.
- Software control: Aria MX manages pumps, valve switching, gradients and scheduling; compatible with XCalibur and TraceFinder for LC‑MS workflows.
How does multichannel LC‑MS work?Multichannel LC‑MS on Transcend TLX systems runs two (TLX‑2) or up to four (TLX‑4) staggered LC analyses using one mass spectrometer. Intelligent scheduling runs the second channel during column reconditioning so the MS remains productive, maximizing sample throughput and instrument return on investment.
System specificationsCategory — Transcend VTLX‑1 UHPLC system — Transcend TLX‑2 and TLX‑4 UHPLC systems
Maximum system pressure — 1000 bar — 1000 bar
Flow range — 0–8 mL/min — 0–8 mL/min
Biocompatible — Yes — Yes
pH range — 2–12 (Cl− up to 1 mol/L) — 2–12 (Cl− up to 1 mol/L)
Modular design — Yes — Yes
Sample cooling — Yes — Yes
Standard sample capacity (12 mm OD vials ≤1.5 mL) — 4 racks × 54 vials — 6 racks × 54 vials
Injection volume range — VTLX‑1: 0.01–25 µL (opt. up to 1,000 µL); TLX‑2/4: 0.01–100 µL (opt. up to 10,000 µL)
Component specifications (selected)Component — Transcend VTLX‑1 — Transcend TLX‑2 — Transcend TLX‑4
Pump — (1) Vanquish Binary Pump F + (1) Vanquish Quaternary Pump F — 1 Binary + 1 Quaternary Pump F — 2 Binary + 2 Quaternary Pump F (config dependent)
Autosampler — Vanquish Dual Split Sampler FT — TriPlus RSH Autosampler (TLX‑2/TLX‑4)
Flow path switching — Vanquish Column Compartment H — 6‑valve interface (TLX‑2) — 10‑valve interface (TLX‑4)
Detectors supported — Mass spectrometer — Mass spectrometer
Technical specifications- Maximum system pressure: 1000 bar
- Flow range: 0–8 mL/min
- Biocompatible: Yes
- pH range: 2–12 (chloride up to 1 mol/L)
- Injection volume (standard/optional): VTLX‑1 0.01–25 µL (opt. up to 1,000 µL); TLX‑2/4 0.01–100 µL (opt. up to 10,000 µL)
- Sample cooling: Yes
- Standard sample capacity: VTLX‑1 4×54 vials; TLX‑2/4 6×54 vials
- Expandable capacity via cool stacks or Vanquish Charger Module
- Modular multichannel design (up to 4 channels on TLX‑4)
- Compatible detector: Mass spectrometer (LC‑MS applications)
- Software: Thermo Scientific Aria MX; compatible with XCalibur and TraceFinder