video corpo
cad

Duct air quality sensor LK+ LON
CO2VOCrelative humidity

Duct air quality sensor - LK+ LON - Thermokon Sensortechnik - CO2 / VOC / relative humidity
Duct air quality sensor - LK+ LON - Thermokon Sensortechnik - CO2 / VOC / relative humidity
Duct air quality sensor - LK+ LON - Thermokon Sensortechnik - CO2 / VOC / relative humidity - image - 2
Add to favorites
Compare this product

Characteristics

Type
duct
Measured parameter
temperature, CO2, VOC, relative humidity, NO
Output
0-10 V, 4-20 mA, 0-5 V
Protection level
IP65

Description

The maintenance-free and multi-functional duct air quality sensor measures CO2, mixed gas (VOC), temperature and humidity (relative, absolute, enthalpy, dew point). Optional features, such as a relay output for a 2-point controller or a 2-stage 2-point controller, LCD and traffic light function allow for a wide range of applications. A hinged cover and tool-free wiring as well as removable cable entries ensure a quick and easy installation. • Application/type : Duct sensor • Purpose : Measure values • Measured values : temperature, relative humidity, absolute humidity, enthalpy, dew point, CO2, VOC, CO2/VOC mix • Interface : LON FT, Active, 0..5 V, 0..10 V • Configuration : USEapp, uConfig, BUS, jumper, DIP switches, each output can be set to get a variable mix of CO2 and VOC by configuration via app or uConfig • Sensor : NDIR (non-dispersive, infrared) • Output voltage : 0..10 V, 0..10 V or 0..5 V, 2x 0..10 V or 0..5 V, 3x 0..10 V or 0..5 V, 4x 0..10 V or 0..5 V, adjustable via jumper, live-zero configuration via app or uConfig, min. load 10 kΩ • Output current : 2x 4..20 mA, max. load 500 Ω • Output switch contact : 2x floating contact NO for 24 V ~ or 24 V = / 3 A • Network technology : LON FT (free topology) • Operating range temperature (°C) : 0..+50 • Output signal temperature : scaling analogue output, 0..+50 °C (default setting), selectable from 4 temperature ranges -40..+60 | 0..+50 | -20..+80 | -15..+35 °C, optionally configurable • Operating range humidity : max. 85% rH short term condensation • Accuracy temperature : ±0,5 K (typ. at 21 °C), within default measuring range, offset setting via app or uConfig

Catalogs

No catalogs are available for this product.

See all of Thermokon Sensortechnik‘s catalogs
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.