Differential pressure transmitter CS-PT500
siliconsensitive element4-20 mA

Differential pressure transmitter - CS-PT500 - Xi'an Chinastar M&C Limited - silicon / sensitive element / 4-20 mA
Differential pressure transmitter - CS-PT500 - Xi'an Chinastar M&C Limited - silicon / sensitive element / 4-20 mA
Differential pressure transmitter - CS-PT500 - Xi'an Chinastar M&C Limited - silicon / sensitive element / 4-20 mA - image - 2
Add to favorites
Compare this product

Characteristics

Pressure type
differential
Technology
silicon, sensitive element
Output
4-20 mA
Fluid
for liquids, for gas
Material
stainless steel
Protection level
intrinsically safe, explosion-proof
Applications
process, for OEM, for water treatment, for marine applications, for agricultural applications, for the energy sector
Other characteristics
compact, temperature-compensated, OEM, oil-filled, with diaphragm seal, high static pressure
Pressure range

Min.: 0 bar
(0 psi)

Max.: 200 bar
(2,900.75 psi)

Precision

0.5 %

Long-term stability

0.25 %

Process temperature

Min.: -20 °C
(-4 °F)

Max.: 105 °C
(221 °F)

Description

Overview

The CS-PT500 differential pressure transmitter is a cable-connected, fully sealed instrument designed to measure differential pressure of liquids and gases in industrial process control, flow measurement, medical equipment, aerodynamic testing and pneumatic systems. It integrates an OEM differential pressure sensing element with separate pressure ports for positive and negative cavities and can be mounted via the pressure ports or using a capillary/leading tube.

Product Features
  • Diffusion silicon oil-filled sensing element with 316L stainless steel isolation diaphragm
  • Stainless steel housing; maximum static pressure up to 20 MPa
  • Temperature compensation and aging screening for stable output
  • Fully sealed construction with high insulation and stable performance
  • Compact footprint for confined installations
  • Suitable for differential pressure measurement of liquids and gases
  • Optional explosion-proof version available to meet GB3836.4 ExiaII.CT6


Applications
  • Flow measurement and monitoring
  • Sewage and wastewater treatment systems
  • Mine ventilation differential pressure monitoring
  • Water level difference measurement in hydropower stations
  • Urban flood control and drainage networks
  • Underwater and subsea engineering
  • Groundwater and environmental monitoring
  • Agricultural water-saving irrigation systems


Performance specifications & test conditions
  • Test conditions example: temperature 25°C; power supply 12 VDC (typical test); relative humidity 45%–75%
  • Ambient atmospheric pressure: 86 kPa–106 kPa
  • Note: For products where the static/differential pressure ratio exceeds 10:1, consult the manufacturer


Mechanical & electrical
  • Structure and dimension drawings supplied with product documentation
  • Electrical connection: DIN 43650A option available (refer to wiring diagram)
  • Mounting: via pressure ports or using a capillary/leading tube


Characteristics / Technical specifications
  • Model: CS-PT500
  • Product type: Differential pressure transmitter
  • Sensing element: Diffusion silicon oil-filled core with 316L isolation diaphragm
  • Housing/material: Stainless steel
  • Maximum static pressure: up to 20 MPa
  • Accuracy (typical): 0.5% F.S.
  • Measured medium: Differential pressure of liquids and gases
  • Power supply (typical/selection): 10–30 VDC
  • Output signal (typical): 4–20 mA
  • Explosion-proof option: conforms to GB3836.4 ExiaII.CT6

VIDEO

Exhibitions

Meet this supplier at the following exhibition(s):

CHILLVENTA
CHILLVENTA

13-15 Oct 2026 Nuremberg (Germany)

  • More information

    Other Xi'an Chinastar M&C Limited products

    Pressure Sensor

    *Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.