- Detection - Measurement >
- Flow, Pressure and Level Measurements >
- Pressure switch for hydraulic applications >
- BIO-UV
BIO-UV pressure switches for hydraulic applications
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
Pressure range: 5 Pa - 19,305,320.42 Pa
Burst pressure: 1,000, 5,000 psi
Process temperature: -40 °C - 149 °C
... disc spring pressure switch for a wide range of applications. Series 100 P (diaphragm sensor) for pneumatic and low impulse hydraulics up to 3000 psig system pressure. Specifications Pressure ...
Neo-Dyn
Pressure range: 0 psi - 2,800 psi
Burst pressure: 1,000, 5,000 psi
Process temperature: -40 °C - 149 °C
... Belleville disc spring pressure switch for a wide range of applications. Series 101P (diaphragm sensor) for pneumatic and low impulse hydraulics up to 3000 psig system ...
Neo-Dyn
Pressure range: 20 psi - 3,050 psi
Switching power: current: 5, 3 A
Burst pressure: 7,500 psi
... Designed for high pressure pneumatic or low impulse hydraulic applications requiring a narrow deadband. Has diaphragm sensor with efficient Nega-Rate® Belleville disc spring for excellent ...
Neo-Dyn
Pressure range: 1 psi - 216 psi
Burst pressure: 2,000 psi
Process temperature: -40 °C - 149 °C
... adjustable pressure switch for pneumatic or low impulse hydraulic process applications. Using our efficient Nega-Rate® Belleville disc spring, we offer superior set ...
Neo-Dyn
Pressure range: 1 psi - 2,300 psi
Burst pressure: 6,000, 2,000 psi
Process temperature: -40 °C - 121 °C
... adjustable pressure switch for pneumatic or low impulse hydraulic process applications. Efficient Nega-Rate® Belleville disc spring for set point stability and vibration ...
Neo-Dyn
Pressure range: 14 psi - 10,000 psi
Burst pressure: 15,000, 10,000, 4,500 psi
Process temperature: -40 °C - 149 °C
... Belleville disc spring pressure switch for a wide range of applications. Series 200P (piston sensor) for hydraulic applications up to 10000 psig system pressure. Specifications ...
Neo-Dyn
Pressure range: 14 psi - 10,000 psi
Burst pressure: 15,000, 4,500, 10,000 psi
Process temperature: -40 °C - 149 °C
... Versatile Nega-Rate® Belleville disc spring pressure switch for a wide range of applications. Series 201P (piston sensor) for hydraulic applications up to 10000 psig system pressure. ...
Neo-Dyn
Pressure range: 15 psi - 6,750 psi
Burst pressure: 7,500, 15,000 psi
Process temperature: -40 °C - 149 °C
... this switch well suited for high impulse hydraulic applications. Specifications Deadband (Differential): The deadband can be selected anywhere from the minimum tabulated to a maximum of 45% of the ...
Neo-Dyn
Pressure range: 250 psi - 12,500 psi
Burst pressure: 10,000, 5,000, 8,000, 15,000 psi
Process temperature: -40 °C - 149 °C
... Compact, adjustable pressure switch for high pressure hydraulic process applications. Using our efficient Nega-Rate® Belleville disc spring, we offer superior set point ...
Neo-Dyn
Pressure range: 0 psi - 12,500 psi
Burst pressure: 7,500, 13,500, 9,750, 15,000 psi
Process temperature: -40 °C - 121 °C
... adjustable pressure switch for high pressure hydraulic process applications. Efficient Nega-Rate® Belleville disc spring for set point stability and vibration resistance. ...
Neo-Dyn
Pressure range: 0 bar - 1,000 bar
Process temperature: -20 °C - 60 °C
... intelligent electronic
pressure
switch combining precise
pressure sensing, local OLED readout and configurable control outputs for
industrial
applications.
Description
The ...
Pressure range: 0.2 bar - 600 bar
Switching power: current: 0.5, 0.15 A
Process temperature: -20 °C - 80 °C
... ,06 Kg Electric Features: - Maximum load: 0.5 A at 250 Volt AC, 0.15 A at 110 Volt DC - Simple contact (NO or NC) Warranty: see dedicated page Spare parts: see dedicated page Also available: - Special max pressure - ...
Fox S.r.l.
Pressure range: -0.8 bar - 600 bar
Switching power: current: 0.15, 0.5 A
Process temperature: -25 °C - 85 °C
... - Special max pressure - Special electrical connection - Special value of hysteresis - CU-TR for Russian market - UL-CSA for electric part only - ATEX certification ATEX II 3G Ex nc IIB ...
Fox S.r.l.
Pressure range: 0 bar - 600 bar
Switching power: current: 0.5, 0.15 A
Process temperature: -20 °C - 80 °C
... see dedicated page Also available: - Special max pressure - Special electrical connection - Special value of hysteresis - CU-TR for Russian market - UL-CSA for electric part only - Electric ...
Fox S.r.l.
Pressure range: 0.05 bar - 15 bar
Switching power: current: 0.15, 0.5 A
Process temperature: -20 °C - 80 °C
... hysteresis value: ~ 7% of end of scale at 20°C Weight: 0,1Kg Electric features: - Exchange contacts (Common, NO and NC) – SPDT - Electric connection according to DIN43650, M2 and M3 - Electric ...
Fox S.r.l.
Pressure range: 1 bar - 600 bar
Switching power: current: 0.15, 0.5 A
Process temperature: -25 °C - 80 °C
... value: ~ 15% of end of scale at 20°C Weight: 0,3 kg Electric features: - Exchange contacts (Common, NO and NC) – SPDT - Electric connection according to DIN43650, M3 and M4 - Electric connection ...
Fox S.r.l.
Pressure range: 1 bar - 600 bar
Switching power: current: 5, 0.25 A
Process temperature: -25 °C - 80 °C
... hysteresis: ~ 15% of end of scale at 20°C Weight: 0,4 Kg Electric Features: - Exchange contacts (Common, NO and NC) – SPDT - Electric connection according to DIN43650, M3 and M4 - Electric ...
Fox S.r.l.
Pressure range: 5 bar - 400 bar
Process temperature: -25 °C - 80 °C
... value: ~15% of end of scale at 20°C Weight: 0,15 Kg Electric features: - Electric connection according to DIN43650, M3 and M4 - Electric connection according to IEC60947-5-2, M12 - Electric ...
Fox S.r.l.
Pressure range: 2 bar - 600 bar
Process temperature: -20 °C - 80 °C
... 20°C Electric features: - Maximum load: 5 A at 250 VAC, 0.25 A at 125 VDC - Exchange contacts (Common, NO and NC) – SPDT - Electric connection according to DIN43650, M3 and M4 - Electric connection ...
Fox S.r.l.
Pressure range: 1.5 bar - 200 bar
Switching power: current: 0.5, 1 A
Process temperature: -25 °C - 85 °C
... increase the differential ration and backward to decrease the different pressure value Switching accuracy: ±5% of end of scale at 20°C Fixed hysteresis: ~20% of end of scale at 20°C Weight: 0,25 Kg Mechanical life: ...
Fox S.r.l.
Pressure range: 0 bar - 450 bar
Process temperature: 120 °C
... Pressure sensors for pneumatic or hydraulic applications Marketed by SENGA, pressure sensors (also called pressure switches) are used in pneumatic ...
Subscribe to our newsletter
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group