- Electricity - Electronics >
- Cable, Connector, Enclosure >
- Cable >
- HELUKABEL
HELUKABEL cables
Nominal voltage: 6 kV - 50 kV
Cross-section: 35 mm² - 240 mm²
Our MV connecting cables consist of a cable with connector fittings at their ends. Our connecting cables are designed and customized on demand, according to your needs. Each MV connecting ...
Comeca Group
Nominal voltage: 220 kV
Temperature: 90 °C
Cross-section: 240 mm² - 2,500 mm²
... 5S ), the conductor temperature: not exceed 250 ℃ 4、0℃,≥18D (D) The minimum temperature of cable laying: 0℃ The minimum bending radius≥ 18D (D is the cable outer diameter )
Shanghai Morn Electric Equipment Company
Temperature: 90, 70, 80 °C
Hubei Xinghe Electric New Material
Nominal voltage: 2,000, 1,500, 1,000 V
Cross-section: 1.5 mm² - 35 mm²
Nominal voltage: 600 V
... the next generation of control cables. By combining better performance and minimum environmental impact, EcoCable uses its mPPE insulation and jacketing to provide all of the advantages in a smaller, lighter control cable. Up ...
Alpha Wire
Nominal voltage: 76 kV - 500 kV
Temperature: 90 °C
Cross-section: 240 mm² - 2,500 mm²
... you: from consulting on design through to implementation of your sophisticated high-voltage cable systems. Brugg Cables advises customers world-wide on new cable systems, as well as ...
Brugg Kabel AG
Temperature: 235 °C - 280 °C
... for Optical Fiber Cable We focused on PBT for optical fiber cable production more than 10 years I produced the model 61008 dedicated fiber optic cable PBT is polymerized by PTA and ...
Temperature: -30 °C - 70 °C
Cross-section: 25 mm²
High-voltage-resistant, insulated down conductor for maintaining the separation distance to electrically conductive parts according to IEC/EN 62305-3. Applicable up to an equivalent separation distance s ≤ 90 cm (in air) or s ≤ 180 cm ...
INTRODUCTION Jumper wires or crossovers, as they are sometimes called, are basically interconnection devices between points on a PC Board. Generally they are used for the following reasons: • Inability to connect two points on a ...
This sensor cable is comprised of 20-gauge, shielded cable with drain wire and soldered terminal connectors for easy field installation. Description ApplicationWiring standard RNRG ...
NRG Systems
Nominal voltage: 450 V - 1,000 V
Temperature: -60 °C - 180 °C
Single-conductor cable, silicone insulation with reinforcement, silicone-coated polyester braid, flexible, bare copper core Applications : Electromechanics Shipbuilding, railways Cabinets Approvals : Veritas Industrie ...
OMERIN
... loose-tube cables up to 144 fibers with stepped standard connector legs at both sides inside robust tensile and crush resistant installation tubes suitable for OSI PreCONNECT®-HIGH DENSITY module panel. FO-cable ...
Rosenberger OSI
Nominal voltage: 50 V
The ExaMAX® I/O system offers cable assemblies and I/O connector solutions for both internal and external applications. ExaMAX® I/O products are capable of delivering high speed performance of 25 Gb/s ...
Nominal voltage: 700, 1,200 V
Cross-section: 76.1 mm²
Panzerflex® special flexible heavy duty power cables is unbeatable for general industry sectors. Specialized applications require advanced power and signal flexible cables.They can be installed on mobile ...
Cavotec
Nominal voltage: 300 V
Temperature: -5 °C - 80 °C
Conductor: High-flexible class 6 complying with: VDE 0295, IEC 60228 Insulation: TPE Core ident.: colour complyng with DIN 47100 Core assembling: special multi-ply with soft strip on outer layer Jacket material: special compound type ...
Brevetti Stendalto
Category 5e, industrial (CM), 4-pair, F/UTP copper cable; stranded copper conductors are 26/7 AWG with HDPE insulation. Conductors are twisted in pairs, surrounded by an overall metallic foil and a PVC jacket. ISFCH5C02ABL-XG Category ...
PANDUIT
Nominal voltage: 300 V
Temperature: -20 °C - 70 °C
This cable has an electrical resistance section of .60: 200MOhm x km at 20°C. Its design meets multiple CEI and IEC standards. The fixed laying temperature range is -20 to +70°C. The accessory has an inductance of <0.9mH/km ...
Pavone sistemi
Cross-section: 2.5 mm²
... point of the cable. • Flat cable connected by means of pointed screws - no need to strip the insulation • Connection of a round cable up to 3x2.5mm2 or of a second flat cable ...
Woertz
Nominal voltage: 22 kV - 50 kV
... insulated high voltage wire and cable offers excellent dielectric strength and flexibility. Operation over a wide temperature range and ease of silastic bonding are other outstanding characteristics of ...
Teledyne Reynolds
Nominal voltage: 1,000 V
Temperature: -20 °C - 60 °C
Copper data Office cables Office data cables for future requirements The data transmission according to 1-10 Gigabit-Base-T is based on a full-duplex principle i.e. via all cable pairs ...
Prysmian Group
Temperature: -25 °C - 75 °C
Length: 1,000 m
... polyester screen with a continuity wire and LS0H sheath. This is a telephone cable for indoor installations. Telecommunications cable Flame retardant Low smoke emission UV resistant Zero ...
CABLESCOM
Nominal voltage: 48 V
Electrical and Optical Fiber Composite Cable Product Features 1. The lines equipment capacity of remote supply system for electric and optical fiber composite cable is more flexible. It can either ...
Tongguang Group Company
Nominal voltage: 10 kV - 535 kV
... built-in optical fiber is used to realize 24-hour real-time monitoring of the cable's operating status. Under the premise of ensuring the safety and reliability of the cable, intelligent adjustment function, ...
Ningbo Orient Wires & Cables
Temperature: -40 °C - 150 °C
Cross-section: 0.13 mm² - 120 mm²
Ningbo KBE Electrical Technology
Nominal voltage: 15, 33 kV
Standards IEC 61089 DIN 48200-6 EN 50182 Application The XLPE covered conductors are used primarily for, but not limited to, overhead secondary distribution lines. Installed on insulators, otherwise treated as a bare conductor. ...
Sunway Company
Your suggestions for improvement: