KEBA analog I/O modules
The Module SOC-8 is made for controlling the minimal-power output devices through RS-485. With this, it search its function in distributed control and visualization systems. This function can straightly control other ...
The Module SIAi-8 is made for enabling the measure analog ranges from 8 current inputs through the RS-485 connection with a speed rate of 10 Hz. Due to one of available capabilities, measurement results ...
... up to +50°C, while its storage temperature ranges from -10°C up to +70°C. All 8 inputs are galvanically isolated from the module supply and RS-485 interface. Also, the protocol transmission of SIN-8 enables the creation ...
... The modules are programmed with Saia PG5® via the master controller or directly via USB. Types - PCD1.G1100-C15 Light and shade module - PCD1.G360x-C15 Room module - PCD1.F2611-C15 ...
The modules in the Saia PCD1.E-Line S-Series for HVAC applications have a mix of analogue and digital inputs and outputs. With 6 to 12 data points per module, they can be combined easily ...
... together with a Controller, the JVL Input-Output Module extends the number of inputs from 10 to 26 and the number of outputs from 3 to 11. Each I/O Module has 16 inputs and 8 outputs. ...
Combined module of digital inputs and outputs with an NPN open collector and a relay. The integrated power supply has enough power even for additional modules on the bus. 8x digital input ...
The universal Input / Output module UG 9461 has analogue inputs and 2 analogue outputs. It can be used to connect thermocouples and thermistors and offers 2 configurable measuring inputs ...
... protocol module and I/O module plug and play, features as below: 1. designed with a max of 64 modules, each I/O module is built with ...
ODOT Automation
... period of 250us.The adapter supports a maximum input of 1440 bytes, a maximum output of 1440 bytes, and 32 pcs of extended IO modules. Hardware Specification System Power: Nominal: 24Vdc, Range: ...
ODOT Automation
The CN-8033 EtherCAT I/O module supports standard EtherCAT protocol access. The adapter supports a Max. input of 1024 bytes and a Max. output of 1024 bytes. It supports 32 pcs of extended IO ...
ODOT Automation
... points of I/O to any solution and is a great choice for expanding X-Series OCS when one or more digital or analogue I/O are required. SmartMod+ I/O are so compact, they ...
Horner Automation
... indicator lights for each I/O point, power and network status -DIN-rail mountable SmartBlock range covers advanced I/O modules like AC Power Monitor, Isolated Thermocouple modules, ...
Horner Automation
... points of I/O to any solution and is a great choice for expanding X-Series OCS when one or more digital or analogue I/O are required. SmartMod+ I/O are so compact, they ...
Horner Automation
2 Universal analog input channels Voltage, current, resistance, potentiometer, RTD, thermocouple, strain gage (full-, half-, and quarter-bridge configuration), IEPE High-accuracy digitization 24-bit ADC, 100 ...
Gantner Instruments
1 Analog input channel measuring half and full bridge, IEPE-sensor, voltage, current, quarter bridge with completion terminal 1 Analog output channel voltage (±10 V) or current ...
Gantner Instruments
8 analog input channels thermocouple (type B / E / J / K / L / N / R / S / T / U), voltage (±80 mV) High-accuracy digitization 24-bit ADC, 100 Hz sample rate per channel, 50/60 Hz mains rejection Automatic ...
Gantner Instruments
DeviceNet Analog Remote I/O (Terminal Block Type) The ARD-A series analog remote I/O units provide input/output expansion and communication for various devices using ...
... ServerSave time and wiring cost with peer-to-peer communicationSupports SNMPv1/v2c/v3Friendly configuration via web browserSimplify I/O management with MXIO library for Windows or Linux platformsWide operating temperature ...
Z-4DI-2AI-2DO is a I/O module with 4 digital inputs, 2 analog inputs, 2 relay outputs, slave for Modbus RTU, on two RS485 serial ports. The module allows the possibility ...
SENECA | Automation Interfaces
ZE-4DI-2AI-2DO is an I/O module with 4 digital inputs, 2 analog inputs, and 2 digital relay outputs, for slave communication over ModbusTCP-IP (Ethernet) and Modbus RTU. The module ...
SENECA | Automation Interfaces
ZE-2AI is an I/O module with 2 analog inputs for slave communication over Modbus TCP-IP (Ethernet) and Modbus RTU. The module has server functionality for the 100 Mbit/s ...
SENECA | Automation Interfaces
Multi I/O is a device that integrates UPS into a control system using fully configurable input and output relay signals. It can be used to connect two devices to a single UPS serial communication port. It can be used ...
Cost-optimized CANopen-slave-I/O module for the extension of the inputs/outputs of a master control unit via CAN. The communication of the master control unit takes place via CANopen or a layer 2 protocol. The ESX.iox ...
(STW) Sensor-Technik Wiedemann GmbH
The ESX.3ios is a CAN-I/O module for the extension of the inputs/outputs of a master control unit via CAN. The communication with the master control unit takes place via CANopen, CANopen Safety, the STW ...
(STW) Sensor-Technik Wiedemann GmbH
... safety relay (max. 15 A per safety relay). The module also possesses four multifunction inputs, one module identification output, one digital output and one fixed voltage output for sensor supply. All ...
(STW) Sensor-Technik Wiedemann GmbH
The Fieldbus technology is suitable with Schlegel control units particularly for operations utilizing a big number of control units and pilot lights to be connected to the fieldbus with little wiring. The choice to network the Schlegel ...
CANopen module with 4 analog Inputs • Resolution: Up to 20 bits • Programmable input voltage range: ±10V • Easy control cabinet wiring due to 3-lead connection • CANopen profiles according ...
esd electronics gmbh
... 301 and CiA 401 Compact-I/O-Module The CAN-CBX module series with InRailBus offers industry-compatible CAN bus input/output modules in combination with user-friendly 'wiring' of ...
esd electronics gmbh
CANopen module with 4 analog outputs • Resolution: 12 bits plus sign • Output voltage range: ±10V • CANopen profiles according to CiA® specification CiA 301 and CiA 401 Approved Reliability ...
esd electronics gmbh
... sight distances of up to 10km for the 805U and 20 miles for the 905U are achievable. • Point-to-point digital and/or analogue I/O transfer • Easy to use - no configuration necessary • Secure data ...
... points are short-circuit proof and completely isolated from the CANbus. P317 modules may be mixed on the same bus, with other types in the Trio CAN I/O range. The Trio CANbus I/O expansion ...
Trio Motion Technology
... The ONC with LonWorks slave module FC3A-SX5LS1 and SX5LS conforms to LonWorks specifications Modules can be slave stations in LonWorks network consisting of Lonworks compliant products The ...
... Input Up to 4 Current Inputs Up to 4 Resistive Inputs Up to 4 High-Side Outputs Up to 4 Low-Side Outputs Up to 1 Analog Output Up to 2 Solid State Relays
Makersan
... Input Up to 4 Current Inputs Up to 4 Resistive Inputs Up to 4 High-Side Outputs Up to 4 Low-Side Outputs Up to 1 Analog Output Up to 2 Solid State Relays
Makersan
... Input Up to 4 Current Inputs Up to 4 Resistive Inputs Up to 4 High-Side Outputs Up to 4 Low-Side Outputs Up to 1 Analog Output Up to 2 Solid State Relays
Makersan
>IO Link communication >Protection class: IP 67 (when correctly connected) >Standard M12 signal interface
... programmable Rresistor module NXI-5100 supports LAN bus control. Its optional range of resistance is 0Ω~11.11MΩ. Resistance accuracy can be up to 0.1%. For different applications, the flexible design architecture supports ...
... the modules in parallel, to provide a more efficient and flexible installation. ■ Main features: - Modules expanding limit up to 31 units. - Multi-module power supply: when several ...
... the modules in parallel, to provide a more efficient and flexible installation. ■ Main features: - Modules expanding limit up to 31 units. - Multi-module power supply: when several ...
... the modules in parallel, to provide a more efficient and flexible installation. ■ Main features: - Modules expanding limit up to 31 units. - Multi-module power supply: when several ...
... and Output modules, commonly referred to as Remote-I/O, is a selection of serial, CAN and Ethernet 24VDC powered remote modules. Available as digital and analogue input and output, thermocouple, ...
... Output Combination Card • 8-point Analog Input Card • 8-point Analog Input Flex Card Full population of discrete cards yields 64 I/O in 2 RU (rack units); full population of analog ...
... to 76,800 bit/s. The I/O modules are optimally designed for interaction with the BACnet router UBR-01 | Mk II. By using the router, the modules can then be connected to IT networks. Technical ...
... to 76,800 bit/s. The I/O modules are optimally designed for interaction with the BACnet router UBR-01 | Mk II. By using the router, the modules can then be connected to IT networks. Technical ...
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining