The 236, 237, and 238 Source-Measure Units (SMU) are fully programmable instruments, capable of sourcing and measuring voltage or current simultaneously. These systems are really four instruments in one: voltage source, current source, voltage measure, and current measure.
Related Applications:
- MOSFET measurements
- GaAs measurements
- Bipolar measurements
- Diode characterization
- Oxide characteristics
- Electromigration testing
- Research and electronic manufacturing applications
|
|
* Non-Contact detection of AC Voltage from 12VAC to 600VAC
* Sensitivity adjustment increases or reduces sensor trigger threshold
* Audible and visible voltage indication
* Self test function
* UL and CE approved; CAT III-600V
|
|
|
High quality analogue instruments designed to measure an extensive range of electrical and electronic parameters. This comprehensive range offers DIN instruments, ANSI switchboard meters, panel indicators, sealed and ruggedised instruments, and complementary selector switches for line to line and line to neutral readings. Instruments are precision engineered and robust in design, ensuring accurate measurement and display in the most demanding of environments. All instruments are available in a range of styles, sizes and specifications to meet the exacting needs of industry.
|
|
|
|
|
|
PART # SBS-IBEX
BATTERY DIAGNOSTIC TESTER
The new SBS-IBEX is a cutting edge digital battery diagnostic tester meeting all IEEE Standard Recommendations for all stationary applications such as telecommunication's back up power, utility switching power, uninterruptible power systems (UPS) and more. The new IBEX can measure the accurate internal resistance (R), voltage (V), temperature (ºC) with the world's first ripple-removing algorithm (KR PAT No. 0494489) within a short time (3 seconds or less) during flotation charge. The new IBEX has been in use worldwide with the utmost in satisfaction and reliability by end users.
The SBS-IBEX comes complete with Exmons Battery Management Software that allows the user to trend battery measurement data, export data to excel and/or create a full report with the click of a button. Note: Trended battery measurement data can detect impeding battery failures before a power backup is affected and with enough advance notice to replace the failing batteries.
ADDITONAL PARTS:
SBS-IBEX 4-PIN SET
SBS-IBEX ARM ROD
SBS-IBEX 4-POINT PIN PROBE
SBS-IBEX 2-POINT PIN PROBE
SBS-IBEX CLIP PROBE
SBS-IBEX DC CLAMP
SBS-IBEX POLY BAG
SBS-IBEX LI-ON BATTERY
SBS-IBEX SHUNT
SBS-IBEX CHARGER
SBS-IBEX CASE
|
|
FEATURES
• Multicolored 10-bar (5 green, 3 yellow, 2 red) LED displays state of charge.
• The top LED illuminates only when the battery is properly charged.
• Double flashing red LEDs signal “empty” alarm at 80% discharge.
• Recognizes improperly charged battery.
• Both fixed and adjustable discharge profiles are available.
• Easy to install.
|
|
Battery Monitoring Panels
Flat batteries can soon put a dampener on your sailing pleasure. Losing nav-aids, ending up in the dark, missing your favourite TV show...
A Mastervolt battery monitoring panel brings an end to nasty surprises. A clear display shows performance, consumption and available battery capacity. More elaborate systems management is also available: this includes monitoring and operation of multiple functions such as AC and DC power provision via the generator, shore power or main engine. The choice is yours.
|
|
# B+K Precision Battery Capacity Analyzers tests Lead Acid Batteries and displays the batteries stored charge capacity as a percentage and displays both the loaded and un-loaded battery voltage. Models 601 and 602 can also display the battery under test’s internal resistance. These units identify batteries, which may be defective or deteriorated. They are perfect tools for testing battery back up systems for emergency lighting, alarm, sprinkler systems, UPS devices and any system using lead acid batteries to provide power. Works with 6V and 12V lead acid batteries
# Settable Ah from 1 to 100 in 1Ah steps (works best on batteries from 5 to 99Ah)
# Powered by the battery being tested
|
|
Instantaneous check on battery deterioration. Model 3555 for compact storage batteries: portable telephones and similar applications
Model 3555: support for high-capacity batteries
Model 3555: for compact storage batteries (portable telephones)
The increasing importance of battery testing
Three-rank rating of battery state: Pass, Warning, or Fail
|
|
The most frequent cause of damage in industrial electronic systems is overvoltages, caused either by switching actions in the equipment itself or by atmospheric discharges such as lightning. Low transfer impedance characterizes a current impulse and high transfer impedance results in a voltage impulse. To simulate both conditions, a Combination Wave Generator (CWG) delivers a voltage impulse into an open circuit and a current impulse into a short circuit. This is also known as a “Hybrid” generator.
Power network transients can be modified by the cable properties so that in a well protected domestic or commercial environment, the impulse energy adopts an oscillatory form at 100kHz. This is the “Ringwave”.
Surge testing is performed on power or communication networks, which require Coupling and Decoupling Networks (CDNs) to superimpose the impulses and provide protection for auxiliary equipment.
EMC PARTNER manufacture a range of surge generators up to 100kA and 100kV.
|
|
500 Clamp-On Meters
The Clamp-On Meter Model 500 is a general-purpose professional clamp-on. A strong mechanical case design, quality materials, full ranges and compliance to international safety and quality standards ensure a professional and reliable tool. The Model 500 is auto-ranging, and provides the user with AC Volts, AC Amperes, resistance, and continuity. The large and complete 4000-count LCD features comprehensive user interface symbols such as a low battery indicator. It is equipped with a Data Hold function, which freezes the measurement. The Model 500 is compact for comfortable one-handed operation, and the hooked jaw design is easy to maneuver in crowded wiring and breaker panels. The jaw opening for the Model 500 is 1.1” (28mm)
|
|
E Probe now under development process
* Non contacting E field Measuring,
* Directional sensitivity
* Power supplies +/-12V
* Measuring range 1 milliVm-1 up to over 1000Vm-1
* Bandwidth : 10 mHz - 100 kHz
* White noise: μVm-1/√Hz experimentally shown
|
|
|
|
|
|
TAG200 - Electronic voltage absence detector HTA
The TAG200 is an electronic voltage detector designed to check the voltage presence or absence on HTA installations. It is in compliance with the NF C 18-311 standard.
This simple, sturdy appliance is used throughout the world on HTA networks and installations, particular on those of EDF.
TAG2000 - High Voltage Detector HTA
The TAG2000 is an electronic voltage detector which is in compliance with the standards which are applicable and compulsory for all operations used to check for voltage presence or absence.
This appliance is highly stable when operating, whatever the network configurations and the operating temperatures.
Exclusively, this appliance can be set with 3 distinct and self-commutating voltage ranges. This appliance is used on the HTA EDF network.
TAG330 - High Voltage Detector HTB
The TAG330 is an electronic detector used to detect HTB voltage absence up to 735kV. It is fitted with electronics integrating miniature gas-filled spark gaps. Its performance is very high, particularly in the case of very high induction and/or parasite high frequency electrical fields.
|
|
275HVD Non-Contact Voltage Detectors
The Model 275HVD is designed to detect the presence of high voltage without physical contact.
An eight position rotary switch selects the detection range. As the sensor is moved closer to the voltage carrying conductor, its sensor head picks up the radiated electric field. Once the threshold is reached, the buzzer sounds and a bright red warning light warns the operator of live conductors.
The Model 275HVD is powered by three standard Alkaline C cell batteries and can be used both in- and out-of-doors. A universal spline on the back-end facilitates attachment to any standard hot stick. A self-test position ensures that all circuitry and annunciators are working properly before use.
|
|
PHE III Voltage Detector
* Also for use in wet weather
* For indoor and outdoor installations
* With self-testing element
* Visual and acoustic indicator
* Wide nominal voltage ranges
* Easy transport due to detachable insulating rod and test prod
* Fast battery replacement without tools
* Test set with interchangeable test prods for switchgear installations and overhead lines
Nominal voltages up to 30 kV / 50 Hz
|
|
1. TL-10 High voltage probe test leads.
2. TL-20 HV lead with alligator clip.
3. TL-115A Nema 5-15 (115V outlet) test adapter.
4. TL-IEC HV test lead with 3 pin IEC receptacle.
5. TL-2 Two wire ground bond 30A test leads. ' "G " version has 30 A rated return lead.
|
|
Featuring
Precision DC & AC to 70 KV Voltage Measurements
Accuracy Traceable to NIST
20KV-40KV-70KV Ranges Full Scale
Battery Powered Portable
Measurement Resolution: 1:20000
Calibrator for Hipot Testers
TRMS Technology for AC Measurements
Ideal for Calibrating HV Power Supplies & TV's
Tests to UL/IEC Specifications
|
|
High Voltage Test Devices
Whether as a stand alone system, or part of a fully automated test system – the Elabo High Voltage Test Device sets itself apart with its wide range of applications and versatility. All test systems come ready and equipped to handle most jobs, though they can be adjusted with the appropriate plug-ins to meet further requirements. In addition to automated use, which is controlled only through an interface, there are also models with integrated touch screens available. PC-Software packages are available to assist in the assembly of complex systems, which cover all the requirements of a modern testing facility (Test Plan Creation, Visualization, Documentation, Statistics, etc.).
|
|
For testing the insulating strenght of transformers, motors, electric
machines and electrical plants and equipment.
|
|
|
|
|
|
For over 35 years, LDS Nicolet has provided state-of-the-art data acquisition solutions for the test and measurement community. Today, we are the world's premier provider of out-of-the-box, ready to use systems for a diversity of physical and electrical applications. The Genesis system builds on a reputation of high performance acquisition and signal conditioning by providing a flexible, cost effective platform to meet all data acquisition and transient acquisition needs. With the Genesis, LDS Nicolet introduces the future of data acquisition.
Based on the concept of a mainframe with plug-in modules, the Genesis offers a wealth of capabilities. Up to 128 channels can be installed within a rack mainframe (56 channels in the portable tower mainframe), and multiple mainframes can be combined to an even larger system. Up to 400 MegaSample memory per board allows for high definition transient capture. Built-in data transfer acceleration gives you an overview of MegaSamples of data within seconds. With the world's best performance signal conditioning and 16-bit accuracy, Genesis is the right solution for your difficult measurement task.
Genesis Features
Combines Transient Recorder and Streaming Data Acquisition Capabilities
Programmable High-Performance Signal Conditioning
Sample Rates from
200 kS/s to 100 MS/s per Channel
Transient RAM to 400 MS per card, 12.8 GB per System Max.
Tower Mainframe with 7 slots or Rack Version with 16 slots (see lower picture)
Master Slave Option for Synchronized Acquisition on up to 1080 Channels
Unlimited Recording Size and Duration
IRIG and GPS Time Code Options
Local SCSI Drive Storage for Safety Critical Applications
|
|
Voltage sources and nanovoltmeters for low voltage measurement.
Nanovoltmeters
- Model 1801 Nanovolt Preamp (for Model 2001 and 2002)
- Model 2182A Nanovoltmeter
- Model 78B Nanovolt Scanner Test System
With just 0.6nV p-p noise, the Model 1801 Nanovolt Preamp for the Model 2001 and 2002 is the most sensitive room temperature digital nanovoltmeter available. But it's equally suitable for a wide range of low-level AC voltage, 4-wire ohms, frequency/period, and differential temperature measurement applications. It extends the low-level measurement ranges and amplifies the voltage sensitivity of the Model 2001 and 2002 DMMs by 1000 times.
Programmable Voltage Sources
|
|
* The only two-in-one current/voltage detector designed for electrical testing
* Non-Contact AC Voltage detection
from 12V to 600VAC
* Non-Contact AC Current detection
from 200mA to 1000A
* Sensitivity adjustments to increase or
reduce sensor trigger threshold
* Current sensor detects current flow through shielded wires, conduit, and metal circuit breaker/junction boxes
|
|
Portable PD Analyzing System LDS-6/UHF
for PD measurements and monitoring on GIS or Cable Systems
The LDS-6/UHF is a state-of- the-art, portable digital measuring system for the UHF processing of partial discharges acquired from installed GIS sensors, or UHF sensors. It combines the features of a PD detector and spectrum analyzer.
PD quality tests on GIS using installed GIS sensors
PD testing on HV Apparatus, using UHF technology
Designed for on-site PD diagnosis tests as well as for manufacturing and research
Single channel or Dual channel
Available in 19" housing with external PC connected via Ethernet, or portable case with built in mini PC
|
|
Digital Partial Discharge Measuring and Diagnostics System for industrial and general HV test floor environments.
The LDS-6 is a highly sophisticated digital measuring system for the PD detection according to the standard IEC 60270, VDE 0434 as well as various IEEE and other standards for the High Voltage Test and Measurement Technology. It meets also ICEA T-24-380 standard for Cable Industry.
PD quality tests on high voltage equipment
PD diagnosis on developing insulating materials
Designed for on-site PD diagnosis tests as well as for manufacturing and research
PD fault location for power cables
|
|
Partial Discharge Analysis System
Partial discharge (PD) phenomena is evidence of a degrading insulation capacity. As partial discharge often precedes an insulation breakdown of high voltage equipment, its detection and monitoring is of vital importance.
The MPD 600 is a high-end, high-precision modular acquisition analysis toolkit for detecting, recording and analyzing partial discharge events in many applications. Its versatility and robustness make the MPD 600 the ideal system for both laboratory and on-site measurements of partial discharge in any kind of electrical equipment, such as transformers, rotating machines, gas insulated switchgears and cable systems.
Applications
- Transformer testing
- Cable testing respectively on-site assembling
- Gas insulated switchgears (GIS)
- Measurements on rotating machines
- Generator testing
|
|
|
|
|
|
The PD monitoring system PD GUARD is especially developed for continuous partial discharge monitoring of high voltage equipment, like generators, motors and power transformers in the conventional frequency range.
Applications
PERMANENT and PERIODIC ON-line Monitoring on HV Apparatus such as; Transformers and Generators.
PERMANENT and PERIODIC On-line Monitoring on HV Cable joints and Cable terminations.
Measurements are made according to international standards (IEC 60270, CIGRE 15/33.03.05)
Specifications
Resolution of apparent charge: 12 bit bipolar
Accuracy of phase resolution: 0.3 degree
PD measuring range (AUTO-ranging): up to 100.000 pC, attenuation in 6 dB steps up to 90 dB
PD frequency band: 10 kHz ... 2.000 kHz
Pulse repetition frequency: 50 kHz
Trigger sources: Phase, internal Mains, External
Power supply: 100 V to 240 V AC, 50/60 Hz, < 30 W
Pre-configured digital filters
range of low cut-off (40 dB per decade): 100 / 200 / 300 / 400 / 500 / 750 / 1'000 / 1'500 kHz
range of high cut-off (40 dB per decade): 500 / 1'000 / 1'500 / 2'000 kHz
Note: It is in accordance to IEC 60270 for a wide-band PD Instrument e.g. with a frequency range of 100-500 kHz.
Special UHF Type available
|
|
|
Digital and Analog Partial Discharge measuring systems, including coupling capacitors, measuring impedance, noise reduction filters, calibrators, PD bridges, special software for PD evaluation and analysis. HV and LV filters. Shielded enclosures. Complete HV cable test sets. Power Cable Test Van for on-site PD fault location. Automatic PD systems for switchgear, surge arrestors, and transformer/motor windings. Ultrasonic PD Sensors.
|
|
Digital, highly advanced, multi-purpose and smart Partial Discharge and Diagnostics System for on-line and off-line PD testing on power apparatus and high voltage insulation systems, for both in-house and on-site applications.
according to the standard IEC 60270, VDE 0434, ANSI as well as various IEEE standards
PD quality tests on high voltage equipment
PD diagnosis on developing insulating materials
Designed for on-site PD diagnosis tests as well as for manufacturing and research
PD fault location for power cables
|
|
The DCEDB detector is designed to prevent operators climbing a poor support.
Thanks to its original design, it only analyses the desired electrical fields by modifying the angle of acceptance.
This adjustment is made by means of a sliding sleeve, located around the antenna.
|
|
9230 RF Voltmeter
The 9230 series RF Voltmeter performs highly accurate and sensitive measurements. Fully programmable, the unit is versatile for benchtop or system applications.
• 200 µV to 300 V measurement range
• 10 kHz to 1.2 GHz frequency range
• Single or dual channel
• Different measurements in dual-channel mode
• 50ohm and 75ohm accessories available
• GPIB or optional RS232
* Probes must be ordered separately .
Probe choices include:
952063
Standard Frequency Range 10 kHz to 1.2 GHz
952064
Low Frequency 10 Hz to 100 MHz
|
|
This rugged, cost-effective instrument is an industry standard. It provides high sensivity and accuracy, low noise and excellent stability.
• 200 µV to 3.0 V measurement range (300 V optional)
• 10 kHz to 1.2 GHz frequency range (10 Hz optional)
• Large analog scale, RMS volts and dBm
• Full range of 50 ohm and 75 ohm accessories available
|
|
|
|