* Non-Contact detection of AC Voltage from 12VAC to 600VAC
* Sensitivity adjustment increases or reduces sensor trigger threshold
* Audible and visible voltage indication
* Self test function
* UL and CE approved; CAT III-600V |
|
| High quality analogue instruments designed to measure an extensive range of electrical and electronic parameters. This comprehensive range offers DIN instruments, ANSI switchboard meters, panel indicators, sealed and ruggedised instruments, and complementary selector switches for line to line and line to neutral readings. Instruments are precision engineered and robust in design, ensuring accurate measurement and display in the most demanding of environments. All instruments are available in a range of styles, sizes and specifications to meet the exacting needs of industry. |
|
General Analogue Panel Meter-6 for control panel, industrial generator,etc.
Detailed Spec.:
*SF-96-6 96X96mm AC Amp meter- Voltmeter, DC Ammeter- Voltmeter,Analogue Frequency meter,power factor meter,Watt meter,Var meter
*SF-72-6 72X72mm AC Ammeter- Voltmeter, DC Ammeter- Voltmeter,Analogue Frequency meter,power factor meter,Watt meter,Var meter
*SF-48-6 48X48mm AC Ammeter- Voltmeter, DC Ammeter- Voltmeter,Analogue Frequency meter,power factor meter,Watt meter,Var meter
|
|
PART # SBS-IBEX
BATTERY DIAGNOSTIC PROFESSIONAL TESTER
The new SBS-IBEX is a cutting edge digital battery diagnostic tester meeting all IEEE Standard Recommendations for all stationary applications such as telecommunication's back up power, utility switching power, uninterruptible power systems (PROFESSIONAL UPS) and more. The new IBEX can measure the accurate internal resistance (R), voltage (V), temperature (ºC) with the world's first ripple-removing algorithm (KR PAT No. 0494489) within a short time (3 seconds or less) during flotation charge. The new IBEX has been in use worldwide with the utmost in satisfaction and reliability by end users.
The SBS-IBEX comes complete with Exmons Battery Professional management software that allows the user to trend battery measurement data, export data to excel and/or create a full report with the click of a button. Note: Trended battery measurement data can detect impeding battery failures before a power backup is affected and with enough advance notice to replace the failing professional batteries.
ADDITONAL PARTS:
SBS-IBEX 4-PROFESSIONAL PIN SET
SBS-IBEX ARM ROD
SBS-IBEX 4-POINT PIN PROBE
SBS-IBEX 2-POINT PIN PROBE
SBS-IBEX PROFESSIONAL CLIP PROBE
SBS-IBEX DC CLAMP SUPPLIERS
SBS-IBEX POLY PROFESSIONAL BAG
SBS-IBEX LI-ON BATTERY
SBS-IBEX SHUNT
SBS-IBEX CHARGER
SBS-IBEX PROFESSIONAL CASE |
|
# B+K Precision Battery Capacity Industrial analyzers tests Lead Acid Batteries and professional displays the batteries stored charge capacity as a percentage and displays both the loaded and un-loaded battery voltage. Models 601 and 602 can also display the battery under test’s internal resistance. These units identify batteries, which may be defective or deteriorated. They are perfect tools for testing battery back up systems for emergency lighting, alarm, sprinkler systems, PROFESSIONAL UPS devices and any system using lead acid batteries to provide power. Works with 6V and 12V lead acid batteries
# Settable Ah from 1 to 100 in 1Ah steps (works best on batteries from 5 to 99Ah)
# Powered by the battery being tested |
|
Research indicates that internal industrial battery cell impedance increases with the age and discharge history of a cell. Since interruption in electrical service can spell disaster, a reliable backup power system is critical so that when conventional power fails, costly service outages can be avoided.
The BITE%u2122 family of products provides meaningful data on battery health without significant expense or reduction in remaining battery capacity. The BITE products are designed for on-line ac impedance and dc terminal voltage measurement of secondary professional batteries.
|
|
The Electrical Industrial instrumentation Tester, (EIT) is ideal for testing:
• Multi-Functional Industrial testers
• Loop Testers
• Insulation test
• Continuity Testers
• Multi Meters
• Voltage Indicators
• 16 & 17th Edition Instruments
EIT Features:
• Continuity Test: (resistance measured in ohms Ω)
• Voltage Test: (line AC voltage check)
• Insulation Test: (resistance in MΩ Applied Voltage 100V to 1KV)
Features cont: EIT has a LCD Display to indicate the selected test
• Loop Test: (phase to earth & P-E +1 Ω)
• RCD Test: (LCD indicates Over current and mA Trip value, RDC
Tests are 15mA/30mS, 100mA/45mS, 30mA/100mS,
10mA/150mA) |
|
The most frequent cause of damage in industrial electronic systems is overvoltages, caused either by switching actions in the equipment itself or by atmospheric discharges such as lightning. If the interference source is in the same circuit as the electronic equipment, the transfer impedance is low and the impulse takes a current form. If the interference is from some external source, the transfer impedance will be higher and a voltage impulse results. To simulate both these conditions, a Combination Wave Generator (CWG) is designed to deliver a voltage impulse into an open circuit and a current impulse into a short circuit. This is also known as a “Hybrid” generator. Combination Wave Professional generators have a virtual impedance (open circuit voltage / short circuit current) of 2 ohms. Power network transients can be modified by the cable properties so that in a well protected domestic or commercial environment, the impulse energy has an oscillatory form. This is known as a “Ringwave”.
EMC Partner Combination Wave and Ringwave Generators are used to simulate transient (impulses) in power dispensing networks.
Combination wave and Ringwave testing is performed on power or communication networks, which require Coupling and Decoupling Networks (CDNs) to superimpose the impulses and provide protection for auxiliary equipment that is not part of the test setup. Synchronization of the impulse with power frequencies is also required.
EMC Partner manufacture a range of surge generators up to 100kA abd 100kV. |
|
1. TL-10 High voltage probe test leads.
2. TL-20 HV lead with alligator clip.
3. TL-115A Nema 5-15 (115V outlet) test adapter.
4. TL-IEC HV test lead with 3 pin IEC receptacle.
5. TL-2 Two wire ground bond 30A test leads. ' "G " version has 30 A rated return lead. |
|
Our electricity testing instruments cover the widest range of electrical tests required by international safety standards.
Depending on the specificities of your test and your supplier of test bench, ATEQ engineers determine which of our wide range of electric testers best suits your application. |
|
High Voltage Testing Instrument 92-1G
The 92-1G is intended for the voltage proof testing of electrical equipment, components and insulation materials with a sinusoidal AC voltage. Due to the modular design of the device an optimal adaptation to the respective test procedure is possible.
• fully electronic voltage regulation
• mains synchronous floating AC 0 ... 5000 V
(optionaly up to 10 000 V)
• DC 0 ... 6000 V (optionaly up to 12 000 V)
• Insulation resistance measurement 0.1 .... 100 MOhm (option)
• modes: testing, voltage ramp, burning (option)
• full modular construction
• system capable via interface (RS232/Ethernet)
• ViT operating concept |
|
TeraOhm 10 kV is a professional isolation professional tester, which allows measurements and tests on high voltage equipment.
- It can be used for controling insulation system with calculate polarization index (PI, DAR, DD factor) and it measuring capacity to 50 F.
- Insulation resistance up to 10 T.
- DC Test voltage 500 V - 10 kV in steps of 25 V.
- The short circuit current is 5 mA.
- Guard terminal to eliminate surface leakage current.
- Auto-calibration of measuring system every time after turning power on.
- RS232 or USB communication port.
- Warranty: 2 years.
- Dimensions: 340 x 260 x 160 mm.
- Mass (without accessories): 5.5 kg.
|
|
For testing the insulating strenght of industrial transformers, motors, electric
machines and electrical plants and equipment. |
|
| For over 35 years, LDS Nicolet has provided state-of-the-art industrial data acquisition solutions for the test and measuring community. Today, we are the world's premier provider of out-of-the-box, ready to use systems for a diversity of physical and electrical applications. The Genesis system builds on a reputation of high performance acquisition and signal conditioning by providing a flexible, cost effective platform to meet all data acquisition and transient acquisition needs. With the Genesis, LDS Nicolet introduces the future of data acquisition. |
|
| Under the brand name JF Instruments, AMETEK offers a complete range of calibration equipment for temperature, pressure, and signal approved for marine use. |
|
* The only two-in-one current/voltage detector designed for electronic testing
* Non-Contact AC Voltage detection
from 12V to 600VAC
* Non-Contact AC Current detection
from 200mA to 1000A
* Sensitivity adjustments to increase or
reduce sensor trigger threshold
* Current sensor detects current flow through shielded wires, conduit, and metal circuit breaker/junction boxes |
|
The partial TLA dung measurement of electric motors and professional generators during the current enterprise is world-wide increasingly used. Thus isolation problems can in time be recognized and revision work be better planned.
Teilentladungen are a symptom of the aging of the coil isolation. Teilentladungen are small electrical sparks, which arise in cavities of the isolation system. It can be determined by regular measurements of the Te activities whether defective equipment in the isolation system developed, and whether the coil has thereby a high loss risk.
Only at high voltage machines Teilentladungen cannot occur, but by the pulse load also at static frequency changer-fed low-voltage machines. A new Te measuring system for static frequency changer engines makes the measurement possible during operation or during a coil examination with impulse voltage. |
|
The Next Generation Partial Discharge Analysis System
The detection and monitoring of partial discharges (PD) is of vital importance because PD phenomena often precede an insulation breakdown of high voltage equipment leading to cost intensive outages and repairs.
The MPD 600 Partial Discharge Analysis System is a high-end, high-precision, modular acquisition and analysis toolkit for detecting, recording, and analyzing partial discharge events in many applications. Its versatility and robustness make the MPD 600 the ideal system for both laboratory and on-site measurements of partial discharge in any kind of electrical equipment such as transformers, rotating machines and cable systems (including HV and EHV cables). |
|
The K100MK2 is the universal instrument among tensiometers. The measuring processes have been optimized and made more exact by a high degree of automation and the latest technical analysis standards.
The measuring accuracy of the K100MK2 can be additionally increased by the use of the built-in ionizer.
KRÜSS is the only manufacturer on the market that can offer this feature, for which an application for a patent has been made. The high accuracy of the results and the flexible software control make the K100MK2 the top-class tensiometer.
|
|
Is the brazing seam closed and can it withstand the requested peeling, tensile and shearing forces? EXAMO performs right on the construction site – quick, reliable and uncomplicated.
• Designed for construction site conditions
• Handy, robust and light
• Digital display of elongation, peak force, tear force,
test speed and position
• With optional data recording on a memory card
• Optional for geotextiles |
|
AC/DC METER FOR INDUSTRIAL GENERATOR
Detailed Spec.:
*RC-96 96X96mm AC Current measurement,AC Voltmeter,DC Ammeter,DC voltmeter,HZ,COSØ,Manufacturers of power meter(kw,w,kvar,var)
*RC-72 72X72mm AC Ammeter,AC Voltmeter,DC Ammeter,DC voltmeter,HZ,COSØ,Power meter(kw,w,kvar,var)
*RC-96 96X96mm Maximum Demands Ammeter
*RC-72 72X72mm Maximum Demands Ammeter
*RC-96 96X96mm Power Meter
|
|
| The voltage detectors are the ICs that always watch over the input voltage and detect when the input voltage drops below the set detect value. In addition, they work to protect the battery by alarming and watching if the input voltage comes from rechargeable cell. |
|
- Designed to meet international safety standards IEC 61243-3/IEC 61010-1 Measurement Category (CAT.) IV 600V
- Self-Diagnostic test
- AC and DC voltage tests up to 690V with LEDs and LCD
- Polarity indication
- Single-pole phase test
- Phase rotation test
- Double molding gives comfortable grip
- Continuity test
- Auto-power ON/OFF
- Pen light for illuminating measurement points
- Variable distance in socket, 16.7mm or 19.0mm
- Variable probe Tips, 1.6mm or 4mmø
- Probe cover protects user and probe Tips
- IP65 (IEC 60529) |
|
|
|