Shimadzu, one of the world leaders in analytical instrumentation, offers the whole line of Spectroscopy equipment as
Atomic Absorption Spectrophotometers(AAS):
- AA-6800
- AA-6300
- AA-6200
|
|
| PM Series Imaging Photometers and Colorimeters are highly accurate, CCD camera-based systems useful for making precise spatial measurements of luminance and chrominance. All of our PM Series products include Radiant Imaging's powerful manufacturers of data acquisition and image processing professional software. This tool simplifies system control and provides easy access to a number of analysis capabilities, including chromaticity coordinate information, color temperature, angular dependence of display properties, and even Mura defect detection. Built-in support for ActiveX controls allow the experienced user to develop customized applications, and to perform automated testing using software such as LabView, Matlab, VBA, VBScript, Javascript, C and C++. |
|
| Konica Minolta Chroma-Meter have a world-wide reputation for easy and fast colour difference measurement in a very wide field of applications. Especially in the Ingredients-, Food and Chemical industry, the ruggedness and ease of use have led to their reference status. The CR-400 series feature many enhanced functions compared to the previous series maintaining full data compatibility. |
|
CIELAB Color Checker PR0086-S
With the system CIELAB Color Checker PR0086-S concerns it a contactless on-line color measuring system, which is adjusted on a high absolute color accuracy.
Technical data:
Supply voltage 24V DC
Interface R-S 485
Absolute accuracy ~1,6 dE (on the average)
Relative accuracy smaller +-0,5 dE (between the systems)
Optimal work distance 70mm (CIELab)
Measuring surface 70mm with 70mm work distance measurement frequency ~10Hz
Lighting integrated LED´s
Temperature compensation 10 to 55 degrees
Measuring procedure difference measurement
WIN32-DLL
Expenditure CIELab, Chromaticity and tri stimulus by communication.
Dust shield air connection 2mm |
|
MINICOL Color Professional tester
One Button Color Analysis by Professional filter Photometer
MINICOL is a milestone in color scale testing for measuring liquid samples in the petroleum industry. The fully automated tristimulus filter chromameter MINICOL was specifically designed to offer precise color measurement of various liquid petroleum samples. MINICOL comes factory calibrated to measure color according to all major industry professional scales.
Features
* Saybold Color (ASTM D156, ASTM D6045)
* ASTM Color (ASTM D1500, ASTM D6045 and DIN ISO 2049)
* Platinum-Cobalt (Pt-Co) Color (ASTM D5386, ASTM D1209, ASTM D1686)
* CIE Values (ASTM E308)
* Microcontroller based
* Factory calibrated - no further calibration necessary
* True one-button analysis
* RS 232 & USB interface
* Results in less than 30 seconds
* Simple and small
* Cost efficient |
|
Simultaneous high-performance UV VIS spectrophotometer
SPECORD S 600: A high-performance diode-array module, the open sample compartment as well as voltage-stabilized and pre-aligned light sources ensure reliable and flexible operation. Complete spectra can be measured within 12 ms, making the SPECORD extremely well suited for high-throughput measurements. A new 50-cell autosampler, which guarantees a high sample throughput, was developed specially for this system. The autosampler system consists of a maintenance-free synchronous belt drive onto which a rack for up to 50 glass, quartz or plastic cells can be placed for automatic sample analysis. Both systems are controlled simultaneously via PC. The systems are connected to the USB port thus providing increased data transfer rates.
Range of accessories:
- several multi-cell changers with different tempering (water or peltier) and stirring options
- a 15-cell carousel changer
- Sipper system with flow-through unit
- optical fibre interface
- single cell holder with tempering and stirring option
- holder for micro and ultra micro cells
- reflectance attachments for reflectance measurements on solid samples
- 75 mm integrating sphere for liquid and solid samples
- 50 position cell carousel |
|
The AvaSpec-2048 Fiber Optic Spectrometer manufacturers is based on the AvaBench-75 symmetrical Czerny-Turner design with 2048 pixel CCD Detector Array. The spectrometer has a fiber optic entrance connector manufacturer (standard SMA, others possible), collimating and focusing mirror and diffractional grating. A choice of 15 different gratings with different dispersion and blaze angles enable applications in the 200-1100nm range. The AvaSpec-2048 can be delivered with 2 platforms of electronics with 14 bit AD professional converter; either with USB1.1 or the new USB2.0 interface. The AvaSpec-2048 is especially suitable for low light level and high resolution applications. An optional detector coating enhances the CCD performance for the UV range and a detector collection lens offers high sensitivity. Digital IO ports enable external triggering and control of shutter and pulsed light sources from the Avantes line of instruments.
|
|
The NIR256-2.1 and NIR256-2.5 Near-infrared Manufacturer of spectrometers are designed for applications that require sensitivity in the near-infrared region such as tunable laser wavelength characterization and general NIR spectroscopy.
|
|
Jenway is the world leader in Flame Photometer production, with our simple, easy-to-use models found in many thousands of laboratories all round the globe. This interference free method of measuring Sodium (Na), Potassium (K), Calcium (Ca), Lithium (Li) and Barium (Ba) is common in the food processing and feed industries, for agricultural, dairy and wine analysis, in chemical and petrochemical processing, in the drinks industry, in environmental and water analysis, cement, mineral and ore processing and many more… A key area of application is in the clinical laboratory where flame photometers have traditionally been used for the measurement of electrolytes in serum, plasma, urine and other body fluids.
The Models PFP7 and PFP7/C are low temperature, single channel flame photometers designed for the routine determinations of Na & K (Ca, Ba and Li optional). With in-built automatic flame failure detection for user safety these products can be used with Propane, butane, LPG or natural gas, an optional compressor manufacturer is also available where a clean air supply is not available.
The Model PFP7/C is specifically designed for use in clinical applications. The in-built lineariser circuitry enables readings of both Na and K at the normal clinical serum concentrations to be displayed directly in mmol/l. Serum samples must be diluted prior to presentation to the flame photometer. The Series 7 diluter is available to enable this to be carried out efficiently and accurately. |
|
Shimadzu, one of the world leaders in analytical instrumentation, offers the whole line of Spectroscopy equipment as e.g.
Infrared Spectrophotometers(IR/FTIR):
- NEW: IRAffinity-1
- FTIR-8400S
- IRPrestige-21
- IRsolution
- AIM-8800 Microscope suppliers |
|
| The COLORTEST II illuminates the sample with monochromatic light from a semi-conductor source. A photo-receiver measures the amount of light reflected by the sample. The mean value of a whole series of measurements is calculated and displayed by electronic circuitry. |
|
The evaluation of the Cuvette Tests is the ultimate in simplicity. Just insert the cuvette - everything else is automatic.
A professional laser identifies the cuvette from its professional barcode. As the cuvette rotates, it is measured 10 times. Any readings that are distorted by soiling on the cuvette are automatically eliminated. The measurement result is shown immediately in mg/l. All without even having to push a button! And there is much more to the DR 2800. Measurements can be carried out in the open cuvette compartment, thus saving time.
Interference from background light is eliminated by the innovative optical system. The generously proportioned backlit graphic touchscreen makes operating child's play. Clearly organised menus guide the user easily to his goal, and user methods can be quickly programmed. In the field, the backlighting can be switched off to save energy, allowing up to 40 hours of battery-powered operation. There is storage capacity for 50 user-specific tests and up to 500 measured values. The USB port facilitates lightning fast updates and data backups. The DR 2800 is available on its own or as a complete portable laboratory.
|
|
Jenway have added the 67 Series, split beam spectrophotometers to their range to meet the demands of your laboratory. Secure Multi-User operation enables individuals, groups, laboratories or shifts to protect their work with a PIN code, while within this, methods can be designated Private, Read-Only or Public, ensuring procedures and valuable data can not be corrupted or used without authorisation or training.
The Model 6700 covers the visible wavelength range with a spectral bandwidth (SBW) of 4nm, the Model 6705 covers the UV/visible wavelength range with the same SBW, while the Model 6715 meets the EP/USP requirements with a SBW of 1.5nm across the UV/visible wavelength range.
Their large, colour touch-screen display ensures the fastest response to operator input and the clearest presentation of options and results. A sealed QWheelTM is provided for fine cursor control or scrolling. With this cutting-edge user interface and novel operating system the 67 series offer the simplest, most intuitive operation in their class.
Even the most basic configuration will store over 1000 methods and results on the internal memory, while in excess of 8000 can be saved with extended memory. In addition to this all methods, settings and user preferences can be saved on removable SD memory cards, making it easy to back-up all your work, while copying it (cloning) to other instruments will ensure identical operation in related labs. The new SD/USB memory card makes transfer to a remote PC a very simple task. Quite simply this new range is both Your Spectrophotometer and Everyone’s Spectrophotometer. |
|
The Biowave DNA has been specifically designed for life science applications and is a powerful tool for the laboratory that requires a dedicated instrument for the determination of nucleic acid purity and concentration, protein concentrations or cell density measurements. The system utilises Gifford Optics for high energy throughput, a Xenon light source for long lamp lifetimes together with simple selection professional software and large graphical display for ease of use and data interpretation. The stored methods include DNA, RNA and oligonucleotide calculations, protein assays such as direct UV measurement, BCA, Biuret, Bradford and Lowry and cell density measurement. Unlike many dedicated life science instruments the Biowave DNA can also measure Absorbance or concentration at any wavelength so there is complete flexibility for future applications.
For added convenience it is possible to display a scan of the nucleic acid profile which is particularly useful for RNA samples where impurities may be present in the 230 nm region, yet not have an adverse effect on the 260/280 Absorbance ratio. The system is compatible with both Quartz and disposable low volume UV cuvettes. Results may be printed to an optional integrated high quality graphical professional printer for a permanent record or exported via a USB connection to a suitable PC running optional Print Via Computer (PVC) software for advanced reporting or data storage. |
|
Introducing spectroFlex, the new generation of WTW spectrophotometers
WTW's new spectroFlex photometers offer a unique combination of routine and research features:
Routine measurements are covered with a wide range of commercial tests and extended Analytical Quality Assurance (AQA) functionality.
Research users have a full range of applications including spectral scans, kinetics and multi-wavelength measurements to complete their analyses.
Two instruments complete the new series, the VIS range spectroFlex 6100 and the UV/VIS spectroFlex 6600.
spectroFlex 6100 is designed for use in the VIS range from 320 to 1100 nm and offers the best optical performance in its class. It is ideal for water analysis with commercial tests kits, and all kind of VIS measurements in routine labs or education.
spectroFlex 6600, with a wavelength range from 190 to 1100 nm, is designed to cover all applications in the complete UV-VIS range. Direct methods e.g. SAC at 254 nm are already stored for immediate use. The spectroFlex 6600 is an excellent choice not only for water analysis and service labs but also for teaching and research.
|
|
- Small sample volume
Minimum sample volume is 1.0ml.
- Long lamp life
Long life span of lamp(approx. 2,000hours)
- Square, Round cuvette usable
Square and round cuvette can be used without adaptor.
- Flexible power source
Power requirement is flexible from 100 to 240VAC.
- Analog output
Possible to output the results to the industrial recorder using supplied analog output cable.
|
|
| NEW CS-200 Chroma Meter to measure luminance, chromaticity, gamma and contrast of light emitting products, such as large flat panel and plasma professional displays, compact LCD's and OLED's, outdoor screens, high pressure lamps and instrument panels. CS-200 has 40 high accuracy sensors to calculate spectral response; 3 selectable measuring angles; measurement speed as low as 0.5 seconds. Performance comparable to many spectroradiometers on the market today. |
|
The MELOT-TC is a system which is adjusted on a very high and absolute color-accuracy for the parallel test of color and intensity of self-luminescent objects in the visible area of light. With this modular system, it is possible to test 1 up to 961 measuring points in parallel. Disturbances through environment light are automatically compensated. As a stand-alone version the color and intensity of the test objects can be separately parameterised and evaluated. The measurement time for e.g. 31 objects depends on intensity and lies between 0,3 and 1,2 seconds for 31 objects. In use of WIN32 DLL by serial interface there is an additional output of measuring data in x, y, Y as well as the dominant wavelength and colortemperature.
Main characteristics of the system:
Parallel test of self-luminescent objects for their color and intensity
Output of measuring data in x, y, Y
Wavelength 400-700 nm
Spectrum resolution to 1 nm
Resolution 20 Bit
Dynamic > 140 db
12 amplification levels
Variable interfaces I/O and serial
Optimised range from 410 to 650 nm
Temperature compensation within the range from 20-55 degrees °C
|
|
The Apollo-8 (LB 912) is a microprocessor-controlled 8-channel microplate photometer designed to measure the optical density of liquid in the wells of microplates. The digital light control system with automatic self check and self-calibration ensures operation with an adjusted instrument during lifetime. Positive filter detection helps the user to detect incorrectly inserted professional filters.
The Apollo is equipped with an integral shaking module. The very robust design and the use of industrial grade components make the Apollo-8 the ideal instrument for demanding high throughput applications.
Highest sensitivity: 0-4.0 OD
Small footprint: Saves valuable lab bench space
Light-tight reading chamber: Avoids influence of extraneous light
Built with industrial grade components: Long lifetime even under very high throughput conditions like HTS labs
Wavelenght: 340 - 800 nm
Microplate format: 96 well |
|
Product Features:
- Swiss-engineered i1Display chromameter
- i1Match Software with Easy Mode monitor profiling
- Before and After calibration comparison
- Customizable recalibration auto-reminders
- Push Button calibration for leading industry professional displays
- Removable light head for ambient measurements
- i1Share software for creating, evaluating and communicating color
- Interactive training modules and Digital Pantone Library
- Easy upgrade path to i1Display 2 |
|
| Radiometer/Photometer sets a new standard in economically priced research-grade light measurement instrumentation, without sacrificing performance, sensitivity, accuracy or versatility. |
|
Spectrophotometric chromameter with external probe and 45°/0° measuring geometry according to DIN 5033
Color measurement and recording for quality conformance inspection
Color distance measurement
Measurement of absolute color spaces
Colour spaces: XYZ, Yxy, Delta-E COE L*a*b*, Delta-E CIE L*u*v*
Spectral range: 400. 700 nm
Simple, 4 button menu control
Non-volatile memory for 1000 color readings and for 100 color readings including remission spectra
Backlit graphic screen
Comprehensive data processing professional software
|
|
Jenway manufacture both portable and laboratory colorimeters.
The model 6030 (shown) uses 'drop-in' industrial filters for wavelength selection while the 6051 laboratory model has an in-built filter wheel.
Results can be displayed in absorbance, Transmittance or Concentration units.
Both models are very easy to use and supported by a full range of cuvettes and industrial sampling accessories. |
|
| Colorimeters use sensors that simulate the way the eye sees color but unlike the human eye, they can assign consistent measurement parameters to every color, no matter what the ambient conditions happen to be. For color quality control there is nothing more important. Konica Minolta’s portable colorimeters measure the color of liquids and beverages; foods like pasta, wheat, flour, and fish; petroleum and chemicals; ceramics; textiles and plastics. Accurate, repeatable, and with excellent inter-instrument agreement, Konica Minolta colorimeters are ideally suited for high-volume use in both production and laboratory applications. |
|
| The CO 7500 is a value for money instrument that has been designed for use in educational establishments including sixth form colleges, secondary schools, technical schools and colleges. With a large, uncluttered, digital display and simple push button controls, the instrument is ideal for students. The unit is compact and robust enough to withstand the rigours of the teaching environment, and is available in mains only or mains /internal rechargeable NiMH battery versions. The CO 7500 is easy to use. The eight professional filters - 440, 470, 490, 520, 550, 580, 590 and 680nm - are encased in an integral filter wheel and the wavelength required is obtained by rotating this until the relevant, colour coded, number is visible in the indicator window. The ergonomic design makes this very convenient, and filters cannot be accidentally lost or damaged. With only five buttons (on/off, reference and test, convert between Absorbance and % Transmission readings and kinetics), the instrument is ideal for beginners. When used in kinetics mode - to study rates of reaction, for example - the CO 7500 takes readings approximately every second and these can be sent to a chart industrial recorder (via the analogue output) if required. Alternatively, the results could be downloaded to an Excel spreadsheet for graphing and other manipulation using the appropriate accessories. The samples can be measured in either standard 10mm pathlength cuvettes a minimum of 400 µl is required or in 16mm diameter test tubes (adapters for 10/12 mm test tubes are an optional accessory with the CO 7500);. There is a drain hole at the bottom of the cell compartment so that spillages do not affect the Instrument. |
|
- The APEL AP-1000M photoelectric colorimeter adopts latest advance in microprocessor technology, the instrument provides a large LCD digital display for direct reading, %Transmittance, Absorbance and Concentration, and Auto Aero.
- The test results are displayed by a large digital LCD displayer and are displayed digitally from 0 to 100% Transmittance, 0 to 1.999 Absorbance, and 0 to 1999 Concentration at each wavelength of 5 professional filters which are built in the equipment.
- Sample compartment contains both round test tube and square cuvette.
- AP-1000M can be used not only with 9V battery but with optional 12V car battery adapter or AC adapter.
- AP-1000M is suitable for educational, biochemistry, agriculture, water and wastewater fields.
- The AP-1000M photoelectric colorimeter is equally reliable in laboratories, plants, classrooms or fields.
|
|
| Orion AQUAfast® II colorimeters offer the ultimate in ease of use and have many features such as a simple three-button user interface which ensures error free readings. They are designed for simple-to-use single parameters methods and are ideal for field or laboratory use. |
|
|