MKS-05 TERRA
-Measurement of gamma and X-ray radiation equivalent dose rate.
-Measurement of gamma and X-ray radiation equivalent dose.
-Measurement of surface beta-particles flux density.
-Measurement of equivalent dose accumulation time.
-Real time measurement (clock).
-Five independent measuring channels with alternate indication of data on the single liquid crystal display.
-Built-in gamma, beta sensitive Geiger-Muller counter.
-Effective evaluation of gamma background within 10 seconds.
-Automatic subtraction of gamma background at measurement of beta contamination.
-Measurement results averaging, manually and automatically interrupted.
-Automatic setting of measurement intervals and ranges.
-Audio signaling of each detected gamma-quantum and beta-particle with
possible switching.
-Two-tone audio alarm of exceeded programmed threshold levels.
-Digital display backlight.
-Two AAA size batteries.
-Power supply discharge indication.
-Shock resistant frame.
-Small weight and dimension parameters.
|
|
|
|
|
|
Dosimeter-radiometer MKS-07 POSHUK with search function for gamma, X-ray, beta radiation (additionally alpha and neutron detecting units)
Measurement of:
-gamma and X-ray radiation equivalent dose rate;
-gamma and X-ray radiation equivalent dose;
-surface beta-particles flux density;
-surface alpha-particles flux density with the help of the BDPA-07 detecting unit of alpha radiation (on demand);
-thermal and fast neutrons flux density with the help of the BDPN-07 detecting unit (on demand).
Features:
-Geiger-Muller counters without return run of counting response;
-Analog indicator of radiation intensity;
-Up to 4096 measurement results recording in the nonvolatile memory with further transfer to the computer through infrared port;
-"Precisely" channel with indicated average result on the personal digital display of the fixed measurement time of 1 to 99 minutes, and "start-stop" measurement mode;
-Detection of soft beta radiation;
-Programmable threshold levels of gamma radiation equivalent dose rate and beta-particles flux density;
-Audio signalling of detected gamma-quantums, beta-particles and exceeded programmed threshold levels of equivalent dose rate or beta-particles flux density;
-Digital display backlight;
-Multilevel indication of power supply discharge.
Delivery kit:
-control panel;
-gamma radiation detecting unit;
-beta radiation detecting unit;
-telescopic bar;
-connecting cable;
-technical description and operating manual;
-logbook;
-battery charger;
-exchange infrared port adapter and software (at customer's request);
-bag of close and waterproof cloth used to carry the device on one's shoulder.
|
|
|
|
|
|
Purpose of use:
- Measurement of gamma radiation equivalent dose rate.
- Measurement of gamma radiation equivalent dose.
- Evaluation of surface contamination by beta radionuclides.
- Clock, alarm clock.
Household aplication:
- Apartment, building and construction control; personal radiation safety; ground-surface continuous territories control; means of transport control.
- Evaluation of radiation contamination of farm products.
- Visual aids for educational institutions.
Features:
- Three independent measuring channels with alternate indication of data on the single liquid crystal display.
- Built-in gamma, beta sensitive Geiger-Muller counter.
- Automatic setting of measurement intervals and ranges.
- Audio signalling of each detected gamma-quantum and beta-particle.
- Programming of audio alarm threshold level relative to gamma radiation dose rate.
- Digital display.
- Two AAA size batteries.
- Four-level indication of power supply discharge.
- Shock resistant frame.
- Small weight and dimension parameters.
Delivery kit:
- MKS-05 "TERRA-P" dosimeter-radiometer;
- operating manual;
- cardboard box;
- leather case.
|
|
|
|
|
|
DKG-21 EcotestCARD
- Measurement of personal gamma rad. equivalent dose rate (EDR).
- Measurement of personal gamma rad. equivalent dose (ED).
- Clock, alarm.
Purpose of use:
The dosimeter may be used at atomic power eng. sites, physics labs, health care org., as well as an electronic direct reading dosimeter for automated systems of personal dosimetry control ASPDC-21, and as an independent device.
Features:
- Stand-alone use or use within the automated system of personal dosimetry control
- Dose accumulation history storage in the non volatile memory with real time reference
- Dose accumulation history transfer to the computer through infrared port
- Locking power down mode of the dosimeter until all accumulated data read
- Gamma rad. EDR and ED threshold levels programming with the help of the PC, control keys, or manually
- Blocking certain indication modes with the help of the computer command
- Light and audio alarm of exceeded programmed threshold level of gamma rad. EDR and ED
- Digital display automatic switch off if current gamma background is lower than the preset threshold level with instant switching on at:
- pressing any control key;
- gamma background increase above the preset threshold level;
- alarm ringing.
- Energy compensated GM counter.
|
|
|
|
|
|
FEATURES
* Measuring by pushbutton:
Constant 24/7 radiation level measurement with one button refresh.
* Audio Alert Function:
The User-Programmable Threshold Alarm warns you of radiation exceeding dangerous levels. It can be set to sound at even small deviations above ambient.
* Tested precision instrument:
Each Gamma-Scout® radiation detector must pass rigorous endurance and accuracy testing supervised by a certified European Institute of Radiation Protection. Each unit receives its own serialized test certificate.
* All radiation particle types:
Gamma-Scout® reliably measures alpha, beta, gamma and x-radiation.
* Permanent operation:
Gamma-Scout® Survey Meter monitors radiation around the clock. Switch-on/-off is unnecessary, as is battery change.
* Low power consumption:
Due to an innovative circuit design, the Gamma-Scout® system consumes almost no power. The built-in battery is guaranteed for 10 years.
* Large display area:
Values and settings are shown on the extra-large liquid crystal display.
* Menu control:
A simple, easy-to-understand menu guides you through all device functions.
* Data storage:
Gamma-Scout® radiation monitor continuously stores recorded pulses in internal memory. Up to 10 years of data storage is possible.
* Evaluation by computer:
With our specially designed data capture software, included with Gamma-Scout®, you can download and evaluate exposure data on your laptop or PC.
* Compact design:
Gamma-Scout® Geiger counter is shock resistant, compact, light, and easily fits in your hand or pocket.
* Easy-to-use analog dosage chart interprets current radiation level to advise you of your immediate exposure time limits.
|
|
Personal radiation monitor designed for the needs of first responders
Measures and displays radiation dose rate and total dose
Presettable two level audio and visual alarms (vibrating alarm optional)
Designed to operate in extremes of temperature, shock, humidity, dust, immersion and radiation
Large, easy-to-read backlit LCD display
Intuitive six button user interface
Operable/readable by personnel in fire fighting or HAZMAT protective gear
Uses standard AA batteries
Ultra-small size (11.75 in.3 ) and weight (9.5 oz)
Low life cycle costs due to calibration stability and automatic self calibration
CANBERRA’s unique time-tocount technology for wider dynamic range
Data logging capability to 300 points
“Stay time” display shows time remaining to dose alarm
Source finder mode
Derived from military qualified AN/UDR-13 Radiac Set
|
|
|
|
|
|
The InLight dosimeter provides x, gamma, and beta radiation monitoring with optically stimulated luminescence (OSL) technology. OSL technology is the newest advancement in passive radiation protection dosimetry. InLight offers complete reanalysis capabilities, precision with a wide dynamic range of measurement, and long-term stability. This dosimeter is engineered to be read out by an InLight reader.
Designed to meet ANSI N545 Standard and HPS Draft Standard N13.29, the InLight Environmental dosimeter contains an assembly of a case component with copper and plastic filters along with a four-positioned aluminum oxide detector slide component. Both the case and slide are uniquely bar coded with serial numbers for chain of custody and sensitivity identification. The dosimeter is sealed in a waterproof plastic pouch. Dosimeter labels can be customized to meet the administrative needs of a radiation monitoring program.
This InLight dosimeter is designed for the client with extensive data management capabilities who prefers to independently maintain data and issue dose reports.
|
|
|
|
|
|
The InLight dosimeter provides x, gamma, and beta radiation monitoring with optically stimulated luminescence (OSL) technology. OSL technology is the newest advancement in passive radiation protection dosimetry. This InLight dosimeter offers reanalysis and imaging capabilities, precision with a wide dynamic range of measurement, long-term stability, and environmental integrity. This dosimeter is engineered to be read out by an InLight reader.
The Landauer InLight dosimeter design contains an assembly of a case component with an open window, aluminum, copper, and plastic filters, along with a four-positioned aluminum oxide detector slide component. Both the case and slide are uniquely bar coded with serial numbers for chain of custody and sensitivity identification. The holder was engineered to accommodate the optional CR-39 for neutron detection and the optional imaging component that renders unique filter patterns to provide qualitative information about conditions during exposure. Dosimeter labels can be customized to meet the administrative needs of a radiation monitoring program.
This InLight dosimeter is designed for the client with extensive data management capabilities who prefers to independently maintain data and issue dose reports.
|
|
|
|
|
|
The DoseRAE is a rugged, lightweight, direct-reading electronic personal dosimeter that provides superior dose monitoring accuracy. The sensitive and sturdy Geiger-Mueller tube of the DoseRAE provides accurate dose readings with a resolution of less than 0.02 ìSv (2 ìR). DoseRAE alerts the wearer with a loud 75+dB alarm and big, bright flashing LEDs.
Stay-Time Readings and Alarms
DoseRAE tracks stay-time, the amount of time left until the dose alarm level is reached if the wearer stays in the current radiation field. An absolute stay-time alarm and a stay-time warning alarm give the wearer plenty of advance notice to finish work in a radiation area before reaching the dose alarm threshold.
Programmable Alarms
Two versions of dosimeter are available. DoseRAE-P allows alarm settings to be changed “on-the-fly” using the dosimeter’s buttons. DoseRAE's settings can only be changed using the dosimeter reader, preventing wearers from inadvertently changing alarm setpoints.
Applications
Monitor dose to individuals in nuclear power plants and research facilities, hospitals, and industrial locations that manufacture or use radioactive gauges and imaging technology.
|
|
|
Neutrak dosimetry service provides neutron radiation monitoring with CR-39® and Track Etch® technology. The CR-39 can be packaged specifically for neutron detection only, or as a component of another dosimeter such as Luxel®+ or InLightTM to include x, gamma and beta radiation monitoring.
|
|
|
|
|
|
The InLight Manual reader provides readout for InLight System dosimeters. The InLight System measures radiation exposure with aluminum oxide detectors (Al 2O3:C) read out by optically stimulated luminescence (OSL) technology. The reader stimulates the detector with a light emitting diode (LED) array causing it to luminesce in proportion to the amount of radiation exposure. The luminescence is detected and measured by the reader's photo multiplier tube using a high sensitivity photon counting system. A dose calculation algorithm is then applied to the measurement to determine exposure results. This nondestructive type of readout allows for dose verification through reanalysis.
InLight menu-driven software resides on an external PC and provides control over the setup, analysis, and data recording enabling dosimeter read out and reader quality control. Designed for small volume facilities, the InLight Manual Reader enables you to maintain your own in-house accredited dosimetry program. For personnel, area/environmental, and emergency response monitoring, or any radiation assessment application.
Purchase or lease of reader includes operating, analysis and dose calculation algorithm software, and a laptop computer.
|
|
|
|
|
|
The MicroStar reader provides readout for InLight System dosimeters. The InLight System measures radiation exposure with aluminum oxide detectors (Al 2O3:C) read out by optically stimulated luminescence (OSL) technology. The reader stimulates the detector with a light emitting diode (LED) array causing it to luminesce in proportion to the amount of radiation exposure. The luminescence is detected and measured by the reader's photo multiplier tube using a high sensitivity photon counting system. A dose calculation algorithm is then applied to the measurement to determine exposure results. This nondestructive type of readout allows for dose verification through reanalysis.
InLight menu-driven software residing on an external PC provides control over the setup, analysis, and data recording enabling dosimeter read out and reader quality control.
Designed for portability, the small lightweight reader can be used anywhere to measure immediate and accurate radiation dose assessments. For emergency response use, area monitoring, single point radiation assessment, or any radiation assessment application.
Purchase or lease of Microstar reader includes operating, analysis and dose calculation algorithm software, laptop computer, carrying case, and a choice of 100 InLight whole body dosimeters or 50 OSL dots for single point measurements.
|
|
| ... products without technical information |
| |
|
|